메뉴 건너뛰기




Volumn 61, Issue 3, 1993, Pages 105-117

CT-guided stereotactic biopsy of nonenhancing brain lesions

Author keywords

AIDS; Brain lesions; Brain tumor; Glioma; Nonenhancing; Stereotactic biopsy

Indexed keywords

ADULT; AGED; ARTICLE; BRAIN INJURY; CLINICAL ARTICLE; CLINICAL TRIAL; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; HUMAN; HUMAN TISSUE; MALE; NEUROSURGERY; SEIZURE; STEREOTAXIC SURGERY;

EID: 0027766205     PISSN: 10116125     EISSN: 14230372     Source Type: Journal    
DOI: 10.1159/000100629     Document Type: Article
Times cited : (26)

References (19)
  • 1
    • 0023212697 scopus 로고
    • Computer imaging stereotaxy: Experience and perspective related to 500 procedures applied to brain masses
    • Apuzzo MU, Chandrasoma PT, Cohen D, Zee CS, Zelman V: Computer imaging stereotaxy: Experience and perspective related to 500 procedures applied to brain masses. Neurosurgery 1987;20:930-937.
    • (1987) Neurosurgery , vol.20 , pp. 930-937
    • Apuzzo, M.U.1    Chandrasoma, P.T.2    Cohen, D.3    Zee, C.S.4    Zelman, V.5
  • 2
    • 0020057835 scopus 로고
    • Calculation of stereotactic coordinates from the computer tomographic scan
    • Gildenberg PL, Kaufman HH, Murthy KSK: Calculation of stereotactic coordinates from the computer tomographic scan. Neurosurgery 1982;10:580-586.
    • (1982) Neurosurgery , vol.10 , pp. 580-586
    • Gildenberg, P.L.1    Kaufman, H.H.2    Murthy, K.S.K.3
  • 3
    • 0021322668 scopus 로고
    • Method of computed tomography-based stereotactic biopsy with arteriographic control
    • Kelly PJ, Alker GJ, Kall BA, Goerss S: Method of computed tomography-based stereotactic biopsy with arteriographic control. Neurosurgery 1984;14:172-176.
    • (1984) Neurosurgery , vol.14 , pp. 172-176
    • Kelly, P.J.1    Alker, G.J.2    Kall, B.A.3    Goerss, S.4
  • 6
    • 0023226581 scopus 로고
    • CT computerized stereotactic biopsy for low density CT lesions presenting with epilepsy
    • Wilden JN, Kelly PJ: CT computerized stereotactic biopsy for low density CT lesions presenting with epilepsy. J Neurol Neurosurg Psychiatry 1987;50:1302-1305.
    • (1987) J Neurol Neurosurg Psychiatry , vol.50 , pp. 1302-1305
    • Wilden, J.N.1    Kelly, P.J.2
  • 8
    • 0025159290 scopus 로고
    • Initial experience related to the use of the Cosman-Roberts-Well stereotactic instrument
    • Couldwell WT, Apuzzo MLJ: Initial experience related to the use of the Cosman-Roberts-Well stereotactic instrument. J Neurosurg 1990;72:145-148.
    • (1990) J Neurosurg , vol.72 , pp. 145-148
    • Couldwell, W.T.1    Apuzzo, M.L.J.2
  • 9
    • 0024322373 scopus 로고
    • Experience in 300 cases of CT-directed stereotactic surgery for lesion biopsy and aspiration of haematoma
    • Thomas DGT, Nouby RM: Experience in 300 cases of CT-directed stereotactic surgery for lesion biopsy and aspiration of haematoma. Br J Neurosurg 1989;3:321-325.
    • (1989) Br J Neurosurg , vol.3 , pp. 321-325
    • Thomas, D.G.T.1    Nouby, R.M.2
  • 10
    • 0023146599 scopus 로고
    • Serial stereotactic biopsies and CT scan in gliomas: Correlative study in 100 astrocytomas, oligo-astrocytomas and oligodendrocytomas
    • Daumas-Duport C, Monsaigneon V, Blond S, Munari C, Musolino A, Chodkiewicz JP, Missir O: Serial stereotactic biopsies and CT scan in gliomas: correlative study in 100 astrocytomas, oligo-astrocytomas and oligodendrocytomas. J Neuro-oncol 1987;4:317-328.
    • (1987) J Neuro-oncol , vol.4 , pp. 317-328
    • Daumas-Duport, C.1    Monsaigneon, V.2    Blond, S.3    Munari, C.4    Musolino, A.5    Chodkiewicz, J.P.6    Missir, O.7
  • 13
    • 0022552910 scopus 로고
    • Further experience utilizing the Gildenberg technique for computed tomography-guided stereotactic biopsies
    • Bullard DE, Osborne D, Burger PC, Nashold BS Jr: Further experience utilizing the Gildenberg technique for computed tomography-guided stereotactic biopsies. Neurosurgery 1986;19:386-391.
    • (1986) Neurosurgery , vol.19 , pp. 386-391
    • Bullard, D.E.1    Osborne, D.2    Burger, P.C.3    Nashold, B.S.4
  • 14
    • 84936273707 scopus 로고
    • CT localization and biopsy of intracranial lesions
    • Schmidek HH, Sweet WH (eds): New York, Grune & Stratton
    • Lunsford LD, Maroon JC: CT localization and biopsy of intracranial lesions; in Schmidek HH, Sweet WH (eds): Operative Neurosurgical Techniques. New York, Grune & Stratton, 1982, pp 403-418.
    • (1982) Operative Neurosurgical Techniques , pp. 403-418
    • Lunsford, L.D.1    Maroon, J.C.2
  • 15
    • 0024403812 scopus 로고
    • The incidence of unexpected pathological findings in an image-guided biopsy series: A series of 100 consecutive cases
    • Friedman WA, Sceats J, Nestok BR, Ballinger WE: The incidence of unexpected pathological findings in an image-guided biopsy series: a series of 100 consecutive cases. Neurosurgery 1989;25(2): 180-184.
    • (1989) Neurosurgery , vol.25 , Issue.2 , pp. 180-184
    • Friedman, W.A.1    Sceats, J.2    Nestok, B.R.3    Ballinger, W.E.4
  • 16
    • 0022334240 scopus 로고
    • CT stereotactic biopsy for optimizing the therapy of intracranial pressure
    • Mundinger F: CT stereotactic biopsy for optimizing the therapy of intracranial pressure. Acta Neurochir Suppl 1985;35:70-74.
    • (1985) Acta Neurochir Suppl , vol.35 , pp. 70-74
    • Mundinger, F.1
  • 17
    • 0025822002 scopus 로고
    • Clues and pitfalls in stereotactic biopsy of the central nervous system
    • Taratuto AL, Sevlever F, Piccardo P: Clues and pitfalls in stereotactic biopsy of the central nervous system. Arch Pathol Lab Med 1991;115:596-602.
    • (1991) Arch Pathol Lab Med , vol.115 , pp. 596-602
    • Taratuto, A.L.1    Sevlever, F.2    Piccardo, P.3
  • 18
    • 0024574690 scopus 로고
    • Stereotactic biopsy in the diagnosis of brain masses: Comparison of results of biopsy and resected surgical specimens
    • Chandrasoma PT, Smith MM, Apuzzo MLJ: Stereotactic biopsy in the diagnosis of brain masses: Comparison of results of biopsy and resected surgical specimens. Neurosurgery 1989;24:160-165.
    • (1989) Neurosurgery , vol.24 , pp. 160-165
    • Chandrasoma, P.T.1    Smith, M.M.2    Apuzzo, M.L.J.3
  • 19
    • 0025959595 scopus 로고
    • Accuracy of stereotactic brain tumor biopsy: Comparison of the histologic findings in biopsy cylinders and resected tumor tissue
    • Feiden W, Steude U, Bise K, Gundisch O: Accuracy of stereotactic brain tumor biopsy: Comparison of the histologic findings in biopsy cylinders and resected tumor tissue. Neurosurg Rev 1991;14:51-56.
    • (1991) Neurosurg Rev , vol.14 , pp. 51-56
    • Feiden, W.1    Steude, U.2    Bise, K.3    Gundisch, O.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.