-
1
-
-
4244085510
-
Magnetic imaging by force microscopy with 1000Å resolution
-
May
-
Y. Martin and H.K. Wickramasinghe: “Magnetic imaging by force microscopy with 1000Å resolution” Appl. Phys. Lett., vol. 50(20), pp 1455-1457, May 1987.
-
(1987)
Appl. Phys. Lett.
, vol.50
, Issue.20
, pp. 1455-1457
-
-
Martin, Y.1
Wickramasinghe, H.K.2
-
2
-
-
36549092964
-
Batch fabricated sensors for magnetic force microscopy
-
(17) Oct.
-
P. Grütter, D. Rugar, H.J. Marmin, G. Castillo, S.E. Lambert, C-J. Lin, R.M. Valletta, O. Wolter, T. Bayer and J. Greschner: “Batch fabricated sensors for magnetic force microscopy” Appl. Phys. Lett., vol. 57(17), No.22, pp. 1820–1822, Oct. 1990.
-
(1990)
Appl. Phys. Lett.
, vol.57
, Issue.22
, pp. 1820-1822
-
-
Grütter, P.1
Rugar, D.2
Marmin, H.J.3
Castillo, G.4
Lambert, S.E.5
Lin, C.-J.6
Valletta, R.M.7
Wolter, O.8
Bayer, T.9
Greschner, J.10
-
3
-
-
36549092318
-
Magnetic force microscopy: General principles and application to longitudinal recording media
-
Aug.
-
D. Rugar, H.J. Mamin, P. Guether, S.E. Lambert, J.E. Stern, I. McFaden and T. Yogi: “Magnetic force microscopy: General principles and application to longitudinal recording media” J. Appl. Phys., vol. 68(3), pp. 1169–1183, Aug.1990.
-
(1990)
J. Appl. Phys.
, vol.68
, Issue.3
, pp. 1169-1183
-
-
Rugar, D.1
Mamin, H.J.2
Guether, P.3
Lambert, S.E.4
Stern, J.E.5
McFaden, I.6
Yogi, T.7
-
4
-
-
0038981463
-
Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivity
-
Jan.
-
T.R. Albrecht, P. Grütter, D. Hone and D. Ruger: “Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivity” J. Appl. Phys., vol. 69(2), pp.668–673, Jan.1991.
-
(1991)
J. Appl. Phys.
, vol.69
, Issue.2
, pp. 668-673
-
-
Albrecht, T.R.1
Grütter, P.2
Hone, D.3
Ruger, D.4
-
5
-
-
0026943787
-
Magnetic force microscope using a direct resonance frequency sensor operating in air
-
Nov.
-
A. Kikugawa, S. Hosaka, Y. Honda and S. Tanaka: “Magnetic force microscope using a direct resonance frequency sensor operating in air” Appl. Phys. Lett., vol. 61(21), pp.2607–2609, Nov. 1992.
-
(1992)
Appl. Phys. Lett.
, vol.61
, Issue.21
, pp. 2607-2609
-
-
Kikugawa, A.1
Hosaka, S.2
Honda, Y.3
Tanaka, S.4
-
6
-
-
0026908142
-
A magnetic force microscope using an optical lever sensor and its application to longitudinal recording media
-
Aug.
-
Y. Honda, S. Hosaka, A. Kikugawa, S. Tanaka, Y. Matsuda, M. Suzuki and M. Futamoto; “A magnetic force microscope using an optical lever sensor and its application to longitudinal recording media” Jpn. J. Appl. Phys., vol. 31, Part 2, No.8A, pp.L1061-L1064, Aug. 1992.
-
(1992)
Jpn. J. Appl. Phys.
, vol.31
, Issue.8A
, pp. L1061-L1064
-
-
Honda, Y.1
Hosaka, S.2
Kikugawa, A.3
Tanaka, S.4
Matsuda, Y.5
Suzuki, M.6
Futamoto, M.7
-
7
-
-
0026257964
-
2magnetic recording at a track density of 17 kTPl
-
Nov.
-
2 magnetic recording at a track density of 17 kTPl” IEEE Trans. Magn., vol. MAG-27, No.6, pp.5280–5285, Nov. 1991.
-
(1991)
IEEE Trans. Magn.
, vol.MAG-27
, Issue.6
, pp. 5280-5285
-
-
Futamoto, M.1
Kugiya, F.2
Suzuki, M.3
Takano, H.4
-
8
-
-
0004931993
-
Micromachining and device transplantation using focused ion beam
-
Oct.
-
T. Ishitani, T. Ohnishi and Y. Kawanami: “Micromachining and device transplantation using focused ion beam “Jpn. J. Appl. Phys., vol. 29, No. 10, pp.2283–2287, Oct. 1990.
-
(1990)
Jpn. J. Appl. Phys.
, vol.29
, Issue.10
, pp. 2283-2287
-
-
Ishitani, T.1
Ohnishi, T.2
Kawanami, Y.3
-
9
-
-
0026824256
-
A study on the field distribution of thin-film heads
-
March
-
H. Takano, H. Fukuoka, M. Suzuki, K. Shiiki and M. Kitada: “A study on the field distribution of thin-film heads” IEEE Trans. Magn., vol. MAG-28, No.2, pp.1024–1030, March 1991.
-
(1991)
IEEE Trans. Magn.
, vol.MAG-28
, Issue.2
, pp. 1024-1030
-
-
Takano, H.1
Fukuoka, H.2
Suzuki, M.3
Shiiki, K.4
Kitada, M.5
-
10
-
-
0026822593
-
Dynamic micromagnetic field measurement by stroboscopic electron beam tomography
-
March
-
H. Shinada, S. Fukuhara, S. Seitou, H. Todokoro, S. Otomo, H. Takano and K. Shiiki: “Dynamic micromagnetic field measurement by stroboscopic electron beam tomography” IEEE Trans. Magn., vol. MAG-28, No.2, pp.1017–1023, March 1992.
-
(1992)
IEEE Trans. Magn.
, vol.MAG-28
, Issue.2
, pp. 1017-1023
-
-
Shinada, H.1
Fukuhara, S.2
Seitou, S.3
Todokoro, H.4
Otomo, S.5
Takano, H.6
Shiiki, K.7
-
11
-
-
0019541496
-
The micromagnetic properties of high-coercivity metallic thin films and their effects on the limit of packing density in digital recording
-
March
-
Tu Chen: “The micromagnetic properties of high-coercivity metallic thin films and their effects on the limit of packing density in digital recording” IEEE Trans. Magn., vol. MAG-17, No.2, pp1181–1191, March 1981.
-
(1981)
IEEE Trans. Magn.
, vol.MAG-17
, Issue.2
, pp. 1181-1191
-
-
Chen, T.1
-
12
-
-
0024112702
-
Physical origin of the performance of thin-film longitudinal recording media
-
Nov.
-
Tu Chen and T. Yamashita: “Physical origin of the performance of thin-film longitudinal recording media” IEEE Trans. Magn., Vol. 24, No.6, pp.2700–2705, Nov.1988.
-
(1988)
IEEE Trans. Magn.
, vol.24
, Issue.6
, pp. 2700-2705
-
-
Chen, T.1
Yamashita, T.2
|