메뉴 건너뛰기




Volumn 40, Issue 4, 1993, Pages 1192-1197

A Fast Projector-Backprojector Pair Modeling the Asymmtric, Spatially Varying Scatter Response Function for Scatter Compensation in SPECT Imaging

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; IMAGE RECONSTRUCTION; MONTE CARLO METHODS; PHOTONS;

EID: 0027649213     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/23.256735     Document Type: Article
Times cited : (94)

References (11)
  • 1
    • 0021373178 scopus 로고
    • Inverse Monte Carlo: a unified reconstruction algorithm
    • C. E. Floyd, R. J. Jaszczak and R. E. Coleman, “Inverse Monte Carlo: a unified reconstruction algorithm,” IEEE. Trans. Nucl. Sci., vol. NS-32, no. 1, pp. 779–785, 1985.
    • (1985) IEEE. Trans. Nucl. Sci , vol.NS-32 , Issue.1 , pp. 779-785
    • Floyd, C.E.1    Jaszczak, R.J.2    Coleman, R.E.3
  • 2
    • 84923326015 scopus 로고
    • A practical method for incorporating scatter in a projector-backprojector for accurate scatter compensation in SPECT
    • Santa Fe, NM
    • E. C. Frey and B. M. W. Tsui, “A practical method for incorporating scatter in a projector-backprojector for accurate scatter compensation in SPECT,” 1991 Nuclear Science Symposium and Medical Imaging Conference, Santa Fe, NM, 1991, pp. 1777–1781.
    • (1991) Nuclear Science Symposium and Medical Imaging Conference , pp. 1777-1781
    • Frey, E.C.1    Tsui, B.M.W.2
  • 3
    • 0025416078 scopus 로고
    • A projector, back-projector pair which accounts for the two-dimensional depth and distance dependent blurring in SPECT
    • B. C. Penney and M. A. King, “A projector, back-projector pair which accounts for the two-dimensional depth and distance dependent blurring in SPECT,” IEEE. Trans. Nucl. Sci., vol. 27, no. 2, pp. 681–686, 1990.
    • (1990) IEEE. Trans. Nucl. Sci , vol.27 , Issue.2 , pp. 681-686
    • Penney, B.C.1    King, M.A.2
  • 4
    • 0041338737 scopus 로고
    • Frequency domain implementation of the three-dimensional geometric point response function correction in SPECT imaging
    • Santa Fe, NM
    • G. L. Zeng and G. T. Gullberg, “Frequency domain implementation of the three-dimensional geometric point response function correction in SPECT imaging,” IEEE Nuclear Science Symposium and Medical Imaging Conference, Santa Fe, NM, 1991, pp. 1943–1947.
    • (1991) IEEE Nuclear Science Symposium and Medical Imaging Conference , pp. 1943-1947
    • Zeng, G.L.1    Gullberg, G.T.2
  • 5
    • 0024713937 scopus 로고
    • A Monte Carlo program for the simulation of scintillation camera characteristics
    • M. Ljungberg and S.-E. Strand, “A Monte Carlo program for the simulation of scintillation camera characteristics,” Comp. Meth. Prog. Biomed., vol. 29, pp. 257–272, 1989.
    • (1989) Comp. Meth. Prog. Biomed , vol.29 , pp. 257-272
    • Ljungberg, M.1    Strand, S.-E.2
  • 6
    • 0343401303 scopus 로고
    • A comparison of scatter compensation techniques in SPECT: subtraction-based techniques versus iterative reconstruction with accurate model of the scatter response
    • Orlando, FL
    • E. C. Frey, B. M. W. Tsui and M. Ljungberg, “A comparison of scatter compensation techniques in SPECT: subtraction-based techniques versus iterative reconstruction with accurate model of the scatter response,” proceedings of the 1992 Nuclear Science Symposium and Medical Imaging Conference, Orlando, F L, 1992.
    • (1992) proceedings of the 1992 Nuclear Science Symposium and Medical Imaging Conference
    • Frey, E.C.1    Tsui, B.M.W.2    Ljungberg, M.3
  • 8
    • 0021260951 scopus 로고
    • Subtraction of Compton-scattered photons in single-photon emission computerized tomography
    • B. Axelsson, P. Msaki and A. Israelsson, “Subtraction of Compton-scattered photons in single-photon emission computerized tomography,” J. Nucl. Med., vol. 25, no. 4, pp. 290–294, 1984.
    • (1984) J. Nucl. Med , vol.25 , Issue.4 , pp. 290-294
    • Axelsson, B.1    Msaki, P.2    Israelsson, A.3
  • 9
    • 0011444843 scopus 로고
    • An integral-transport method for Compton-scatter correction in emission computed tomography
    • S. R. Egbert and R. S. May, “An integral-transport method for Compton-scatter correction in emission computed tomography,” IEEE. Trans. Nucl. Sci., vol. NS-27, no. 1, pp. 543–547, 1980.
    • (1980) IEEE. Trans. Nucl. Sci , vol.NS-27 , Issue.1 , pp. 543-547
    • Egbert, S.R.1    May, R.S.2
  • 10
    • 0024997705 scopus 로고
    • Scatter and attenuation correction in SPECT using density maps and Monte Carlo simulated scatter functions
    • M. Ljungberg and S.-E. Strand, “Scatter and attenuation correction in SPECT using density maps and Monte Carlo simulated scatter functions,” J. Nucl. Med., vol. 31, no. 9, pp. 1560–1567, 1990.
    • (1990) J. Nucl. Med , vol.31 , Issue.9 , pp. 1560-1567
    • Ljungberg, M.1    Strand, S.-E.2
  • 11
    • 0026371160 scopus 로고
    • Comparison between ML-EM and WLS-CG algorithms for SPECT image reconstruction
    • B. M. W. Tsui, X. D. Zhao, E. C. Frey and G. T. Gullberg, “Comparison between ML-EM and WLS-CG algorithms for SPECT image reconstruction,” IEEE. Trans. Nucl. Sci., vol. 38, no. 6, pp. 1766–1772, 1991.\\\\\\\\
    • (1991) IEEE. Trans. Nucl. Sci , vol.38 , Issue.6 , pp. 1766-1772
    • Tsui, B.M.W.1    Zhao, X.D.2    Frey, E.C.3    Gullberg, G.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.