메뉴 건너뛰기




Volumn 40, Issue 4, 1993, Pages 1092-1101

A Reconstruction Algorithm for Helical Cone-Beam SPECT

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; BRAIN; IMAGE RECONSTRUCTION; PHOTONS;

EID: 0027647186     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/23.256718     Document Type: Article
Times cited : (23)

References (18)
  • 1
    • 0023036102 scopus 로고
    • Three-dimensional single photon emission computed tomography using cone beam collimation (CB-SPECT)
    • R. L. Jaszczak, C. E. Floyd, S. H. Manglos, K. L. Green, and R. E. Coleman, “Three-dimensional single photon emission computed tomography using cone beam collimation (CB-SPECT),“ SPIE 671 193–199 (1986).
    • (1986) SPIE , vol.671 , pp. 193-199
    • Jaszczak, R.L.1    Floyd, C.E.2    Manglos, S.H.3    Green, K.L.4    Coleman, R.E.5
  • 2
    • 0022525205 scopus 로고
    • Cone beam collimation for single photon emission computed tomography: analysis, simulation, and image reconstruction using filtered backprojection
    • R. L. Jaszczak, C. E. Floyd, S. H. Manglos, K. L. Green, and R. E. Coleman, “Cone beam collimation for single photon emission computed tomography: analysis, simulation, and image reconstruction using filtered backprojection,” Med. Phys. 13 484–489 (1986).
    • (1986) Med. Phys , vol.13 , pp. 484-489
    • Jaszczak, R.L.1    Floyd, C.E.2    Manglos, S.H.3    Green, K.L.4    Coleman, R.E.5
  • 3
    • 33745506176 scopus 로고
    • Single photon emission computed tomography of the heart using cone beam geometry and non-circular detector rotation
    • Berkeley, July, ed D. A. Ortendahl and J. Lacer (New York: Wiley)
    • G. T. Gullberg, G. L. Zeng, P. E. Christian, B. M. W. Tsui and H. T. Morgan, “Single photon emission computed tomography of the heart using cone beam geometry and non-circular detector rotation,” Information Processing in Medical Imaging, XIth IPMI International Conference (Berkeley, July 1989), ed D. A. Ortendahl and J. Lacer (New York: Wiley) pp 123–138.
    • (1989) Information Processing in Medical Imaging, XIth IPMI International Conference , pp. 123-138
    • Gullberg, G.T.1    Zeng, G.L.2    Christian, P.E.3    Tsui, B.M.W.4    Morgan, H.T.5
  • 6
    • 0026838538 scopus 로고
    • A cone-beam filtered backprojection reconstruction algorithm for cardiac single photon emission computed tomography
    • G. T. Gullberg and G. L. Zeng, “A cone-beam filtered backprojection reconstruction algorithm for cardiac single photon emission computed tomography,” IEEE Trans. on Med. Imag., MI-1(11), 91–101 (1992).
    • (1992) IEEE Trans. on Med. Imag , vol.MI-1 , Issue.11 , pp. 91-101
    • Gullberg, G.T.1    Zeng, G.L.2
  • 7
    • 0020764170 scopus 로고
    • An inversion formula for cone-beam reconstruction
    • H. K. Tuy, “An inversion formula for cone-beam reconstruction,” SIAM J. Appl. Math. 43, 546–552 (1983).
    • (1983) SIAM J. Appl. Math , vol.43 , pp. 546-552
    • Tuy, H.K.1
  • 9
    • 0002018761 scopus 로고
    • Mathematical framework of cone-beam 3D reconstruction via the first derivative of the radon transform
    • G. T. Herman, A. K. Lous, F. Natterer, Eds., Lecture Notes in mathematics, Springer-Verlag
    • P. Grangeat, “Mathematical framework of cone-beam 3D reconstruction via the first derivative of the radon transform,” in Mathematical Methods in Tomography, G. T. Herman, A. K. Lous, F. Natterer, Eds., Lecture Notes in mathematics, Springer-Verlag, (1990).
    • (1990) Mathematical Methods in Tomography
    • Grangeat, P.1
  • 10
    • 0001528111 scopus 로고
    • Comparison of two three-dimensional x-ray cone-beam-reconstruction algorithms with circular source trajectories
    • P. Rizo, P. Grangeat, P. Sire P. Lemasson, and P. Melennec, “Comparison of two three-dimensional x-ray cone-beam-reconstruction algorithms with circular source trajectories,” J. Opt. Soc. Am. A 8, 1639–1647 (1991).
    • (1991) J. Opt. Soc. Am. A , vol.8 , pp. 1639-1647
    • Rizo, P.1    Grangeat, P.2    Sire, P.3    Lemasson, P.4    Melennec, P.5
  • 12
    • 0026552271 scopus 로고
    • A cone-beam tomography algorithm for orthogonal circle-and-line orbit
    • G. L. Zeng and G. T. Gullberg, “A cone-beam tomography algorithm for orthogonal circle-and-line orbit,” Phys. Med. Biol. 37, 563–577 (1992).
    • (1992) Phys. Med. Biol , vol.37 , pp. 563-577
    • Zeng, G.L.1    Gullberg, G.T.2
  • 13
    • 0026544832 scopus 로고
    • Cone beam tomography with circular, elliptical and spiral orbits
    • X. Yan and R. M. Leahy, “Cone beam tomography with circular, elliptical and spiral orbits,” Phys. Med. Biol. 37, 493–506 (1992).
    • (1992) Phys. Med. Biol , vol.37 , pp. 493-506
    • Yan, X.1    Leahy, R.M.2
  • 14
    • 0025654010 scopus 로고
    • Feasible cone beam scanning methods for exact reconstruction in three-dimensional tomography
    • H. Kudo and T. Saito, “Feasible cone beam scanning methods for exact reconstruction in three-dimensional tomography,” J. Opt. Soc. Am. A 7, 2169–2183 (1990).
    • (1990) J. Opt. Soc. Am. A , vol.7 , pp. 2169-2183
    • Kudo, H.1    Saito, T.2
  • 15
    • 0022026907 scopus 로고
    • Image reconstruction from cone-beam projections: necessary and sufficient conditions and reconstruction methods
    • B. D. Smith, “Image reconstruction from cone-beam projections: necessary and sufficient conditions and reconstruction methods,” IEEE Trans. on Med. Imag., MI-4(1), 14–25 (1985).
    • (1985) IEEE Trans. on Med. Imag , vol.MI-4 , Issue.1 , pp. 4-25
    • Smith, B.D.1
  • 17
    • 0001169360 scopus 로고
    • Uber die bestimmung von funktionen durch ihre integralwerte langs gewisser mannigfaltikeiten
    • J. Radon, “Uber die bestimmung von funktionen durch ihre integralwerte langs gewisser mannigfaltikeiten,” Ber. Saechsische Akad. Wiss., Vol. 69, pp 262–278, (1917).
    • (1917) Ber. Saechsische Akad. Wiss , vol.69 , pp. 262-278
    • Radon, J.1
  • 18
    • 0020204372 scopus 로고
    • An improved algorithm for reprojecting rays through pixel images
    • P. M. Joseph, “An improved algorithm for reprojecting rays through pixel images,” IEEE Trans. on Med. lmag., MI-1(3), 192–196 (1980).
    • (1980) IEEE Trans. on Med. lmag , vol.MI-1 , Issue.3 , pp. 192-196
    • Joseph, P.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.