메뉴 건너뛰기




Volumn 12, Issue 2, 1993, Pages 251-259

Mr susceptibility misregistration correction

Author keywords

[No Author keywords available]

Indexed keywords

AIR; COMPUTERIZED TOMOGRAPHY; ERROR CORRECTION; MAGNETIC PROPERTIES; MAGNETIC VARIABLES MEASUREMENT; MAGNETOMETERS; PARAMETER ESTIMATION; PHASE INTERFACES; SIGNAL DISTORTION; TISSUE;

EID: 0027610536     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/42.232253     Document Type: Article
Times cited : (119)

References (34)
  • 3
    • 0025599088 scopus 로고
    • Geometric image transformation to compensate for MRI distortions
    • H. Chang and J. M. Fitzpatrick, “Geometric image transformation to compensate for MRI distortions,” SPIE Med. Imaging IV: Image vol. 1233, 116–127, 1990.
    • (1990) SPIE Med. Imaging IV: Image , vol.1233 , pp. 116-127
    • Chang, H.1    Fitzpatrick, J.M.2
  • 4
    • 0025022338 scopus 로고
    • Magnetic susceptibility effects of trabecular bone on magnetic resonance imaging of bone marrow
    • H. Rosenthal, K. R. Thulbom, D. Rosenthal, S. H. Kim, and B. R. Rosen, “Magnetic susceptibility effects of trabecular bone on magnetic resonance imaging of bone marrow,” Invest. Radiol., vol. 25, pp. 173–178, 1990.
    • (1990) Invest. Radiol , vol.25 , pp. 173-178
    • Rosenthal, H.1    Thulbom, K.R.2    Rosenthal, D.3    Kim, S.H.4    Rosen, B.R.5
  • 5
    • 84945725084 scopus 로고
    • Rapid, fully-automatic, arbitrary volume in-vivo shimming
    • P. Webb and A. Macovski, “Rapid, fully-automatic, arbitrary volume in-vivo shimming,” Magn. Resonance in Med., 1990.
    • (1990) Magn. Resonance in Med
    • Webb, P.1    Macovski, A.2
  • 7
    • 0003714630 scopus 로고
    • Segmentation and distortion correction in medical imaging
    • Dep. Elec. Eng., Stanford Univ., Stanford, CA
    • T. S. Sumanaweera, “Segmentation and distortion correction in medical imaging,” Ph.D. Dissertation, Dep. Elec. Eng., Stanford Univ., Stanford, CA 1992.
    • (1992) Ph.D. Dissertation
    • Sumanaweera, T.S.1
  • 8
    • 84945725085 scopus 로고
    • private communication, General Electric Med. Syst., Schenectedy, NY
    • G. H. Glover, private communication, General Electric Med. Syst., Schenectedy, NY, 1983.
    • (1983)
    • Glover, G.H.1
  • 9
    • 0026216918 scopus 로고
    • Multipoint Dixon technique for water and fat proton and susceptibility imaging
    • G. H. Glover, “Multipoint Dixon technique for water and fat proton and susceptibility imaging,” Magn. Resonance Imaging, pp. 521–530, 1991.
    • (1991) Magn. Resonance Imaging , pp. 521-530
    • Glover, G.H.1
  • 10
    • 0021132985 scopus 로고
    • Simple proton spectroscopic imaging
    • W. T. Dixon, “Simple proton spectroscopic imaging,” Radiol., vol. 153, pp. 189–194, 1984.
    • (1984) Radiol , vol.153 , pp. 189-194
    • Dixon, W.T.1
  • 11
    • 0022461655 scopus 로고
    • The effects of bone on proton NMR relaxation times of surrounding liquids
    • C. A. Davis, H. K. Genant, and J. S. Dunham, “The effects of bone on proton NMR relaxation times of surrounding liquids,” Invest. Radiol., vol. 21, pp. 412-411, 1986.
    • (1986) Invest. Radiol , vol.21 , pp. 411-412
    • Davis, C.A.1    Genant, H.K.2    Dunham, J.S.3
  • 12
    • 0017940980 scopus 로고
    • NMR image recovery under magnetic fields with large non-uniformities
    • Inst. Phys., Great Britain
    • J. M. S. Hutchison, R. J. Sutherland, and J. R. Mallard, “NMR image recovery under magnetic fields with large non-uniformities,” J. Phys. E Sci. Instrum., vol. 11, pp. 217–221, 1978, Inst. Phys., Great Britain.
    • (1978) J. Phys. E Sci. Instrum , vol.11 , pp. 217-221
    • Hutchison, J.M.S.1    Sutherland, R.J.2    Mallard, J.R.3
  • 13
    • 0008899919 scopus 로고
    • Reconstructing NMR images under magnetic fields with large inhomogeneities
    • Inst. Phys., Great Britain
    • M. Lai, “Reconstructing NMR images under magnetic fields with large inhomogeneities,” J. Phys. E.Sci. Instrum., vol. 15, pp. 1093–1100, 1982, Inst. Phys., Great Britain.
    • (1982) J. Phys. E. Sci. Instrum , vol.15 , pp. 1093-1100
    • Lai, M.1
  • 14
    • 0021182427 scopus 로고
    • Image restoration from nonuniform magnetic field influence for direct Fourier NMR imaging
    • Inst. Phys., Great Britain
    • K. Sekihara, M. Kuroda, and K. Kohno, “Image restoration from nonuniform magnetic field influence for direct Fourier NMR imaging,” Phys. Med. Biol., vol. 29, no. 1, pp. 15–24, 1984, Inst. Phys., Great Britain.
    • (1984) Phys. Med. Biol , vol.29 , Issue.1 , pp. 15-24
    • Sekihara, K.1    Kuroda, M.2    Kohno, K.3
  • 15
    • 0022189419 scopus 로고
    • NMR imaging for magnets with large nonuniformities
    • K. Sekihara, S. Matsui, and H. Kohno, “NMR imaging for magnets with large nonuniformities,” IEEE Trans. Med. Imaging, vol. MI-4, pp. 193–199, Dec. 1985.
    • (1985) IEEE Trans. Med. Imaging , vol.MI-4 , pp. 193-199
    • Sekihara, K.1    Matsui, S.2    Kohno, H.3
  • 16
    • 0002071843 scopus 로고
    • Correction of geometric distortion in MR-images
    • New York: Computer Assisted Berlin, Germany, Radiology, Springer-Verlag
    • F. Schmitt, “Correction of geometric distortion in MR-images,” in Proc. Int. Symp. CAR’85, Berlin, Germany, 1985, pp. 15–23. New York: Computer Assisted Radiology, Springer-Verlag.
    • (1985) Proc. Int. Symp. CAR'85 , pp. 15-23
    • Schmitt, F.1
  • 17
    • 0344856491 scopus 로고
    • Correction of distortion caused by field errors in MR imaging
    • Soc. Magn. Resonance in Med
    • E. Yamamoto and H. Kohno, “Correction of distortion caused by field errors in MR imaging,” in Book of Abstracts, Soc. Magn. Resonance in Med., 1987, p. 402.
    • (1987) Book of Abstracts , pp. 402
    • Yamamoto, E.1    Kohno, H.2
  • 18
    • 0023883943 scopus 로고
    • The total inhomogeneity correction including chemical shift and susceptibility by view angle tilting
    • Z. H. Cho, D. J. Kim, and Y. K. Kim, “The total inhomogeneity correction including chemical shift and susceptibility by view angle tilting,” Med. Phys., vol. 15, Jan./Feb. 1988.
    • (1988) Med. Phys , vol.15
    • Cho, Z.H.1    Kim, D.J.2    Kim, Y.K.3
  • 19
    • 0003987860 scopus 로고
    • Geometrical distortion of magnetic resonance images
    • McGill Univ., Montreal, Quebec
    • A. Gauvin, “Geometrical distortion of magnetic resonance images,” M.Sc. Thesis, Dep. Phy., McGill Univ., Montreal, Quebec, 1992.
    • (1992) M. Sc. Thesis, Dep. Phy
    • Gauvin, A.1
  • 20
    • 84945725086 scopus 로고
    • Self-correcting NMR image recovery under magnetic fields with large inhomogeneities
    • Soc. Magn. Resonance in Med
    • E. Feig, F. Greenleaf, and M. Perlin, “Self-correcting NMR image recovery under magnetic fields with large inhomogeneities,” in Book of Abstracts, Soc. Magn. Resonance in Med., 1984, 227.
    • (1984) Book of Abstracts , pp. 227
    • Feig, E.1    Greenleaf, F.2    Perlin, M.3
  • 21
    • 0022552303 scopus 로고
    • Magnetic resonance imaging with nonuniform fields
    • Inst. Phys., Great Britain
    • E. Feig, F. Greenleaf, and M. Perlin, “Magnetic resonance imaging with nonuniform fields,” Phys. Med. Biol., vol. 31, no. 10, pp. 1091–1099, 1986, Inst. Phys., Great Britain.
    • (1986) Phys. Med. Biol , vol.31 , Issue.10 , pp. 1091-1099
    • Feig, E.1    Greenleaf, F.2    Perlin, M.3
  • 23
    • 0023747444 scopus 로고
    • MR imaging of susceptibility-induced magnetic field inhomogeneities
    • R. E. Wendt, M. R. Wilcott, W. Nitz, P. H. Murphy, and R. N. Bryan, “MR imaging of susceptibility-induced magnetic field inhomogeneities,” Radiol., vol. 168, 837–841, 1988.
    • (1988) Radiol , vol.168 , pp. 837-841
    • Wendt, R.E.1    Wilcott, M.R.2    Nitz, W.3    Murphy, P.H.4    Bryan, R.N.5
  • 24
    • 84945715945 scopus 로고
    • Instant magnetic field mapping
    • Soc. Magn. Resonance in Med
    • R. M. Weisskoff and M. S. Cohen, “Instant magnetic field mapping,” in Book of Abstracts, Soc. Magn. Resonance in Med., 1989, p. 223.
    • (1989) Book of Abstracts , pp. 223
    • Weisskoff, R.M.1    Cohen, M.S.2
  • 25
    • 84945725087 scopus 로고
    • A new general purpose multislice pulse sequence for field and susceptibility mapping
    • Soc. Magn. Resonance in Med
    • J. P. Mugler and J. R. Brookeman, “A new general purpose multislice pulse sequence for field and susceptibility mapping,” in Book of Abstracts, Soc. Magn. Resonance in Med., 1989, p. 1160.
    • (1989) Book of Abstracts
    • Mugler, J.P.1    Brookeman, J.R.2
  • 26
    • 0025832805 scopus 로고
    • Rapid in-vivo proton shimming
    • E. Schneider and G. H. Glover, “Rapid in-vivo proton shimming,” Magn. Resonance in Med., vol. 18, pp. 335–347, 1991.
    • (1991) Magn. Resonance in Med , vol.18 , pp. 335-347
    • Schneider, E.1    Glover, G.H.2
  • 28
    • 84945725088 scopus 로고
    • Local steo edge estimation: A new algorithm, statistical model and performance evaluation
    • S. J. Wang and T. O. Binford, “Local steo edge estimation: A new algorithm, statistical model and performance evaluation,” Proc. Image Understanding Workshop, DARPA, 1993.
    • (1993) Proc. Image Understanding Workshop, DARPA
    • Wang, S.J.1    Binford, T.O.2
  • 29
    • 0022808786 scopus 로고
    • A computational approach to edge detection
    • J. Canny, “A computational approach to edge detection,” IEEE Trans. Pattern Anal. Machine Intell., vol. PAMI-8, pp. 676–697, Nov. 1986.
    • (1986) IEEE Trans. Pattern Anal. Machine Intell , vol.PAMI-8 , pp. 676-697
    • Canny, J.1
  • 30
    • 1542734561 scopus 로고
    • Stereo matching of skull landmarks
    • Dep. Elec. Eng
    • B. U. Lee, “Stereo matching of skull landmarks,” Ph.D. Dissertation, Dep. Elec. Eng., Stanford Univ., Stanford, CA 1991.
    • (1991) Ph.D. Dissertation
    • Lee, B.U.1
  • 32
    • 0003965863 scopus 로고
    • A ready-reference book of chemical and physical data Boca Raton, FL:CRC Press
    • D. R. Lide, Ed., CRC Handbook of Chemistry and Physics. Boca Raton, FL: CRC Press, 1990. A ready-reference book of chemical and physical data.
    • (1990) CRC Handbook of Chemistry and Physics
    • Lide, D.R.1
  • 33
    • 84945725089 scopus 로고
    • private communication
    • Sullivan Park Corning, NY
    • J. Schreurs, private communication, Coming Res. Cen., Sullivan Park, Corning, NY, 1991.
    • (1991) Coming Res. Cen
    • Schreurs, J.1
  • 34
    • 84945725090 scopus 로고
    • MRI registration correction for stereotaxis surgery
    • American Association of Neurological Surgeons, New Orleans, LA
    • T. S. Sumanaweera and J. R. Adler, “MRI registration correction for stereotaxis surgery,” Proc. Annual Meeting of the American Association of Neurological Surgeons, New Orleans, LA, Apr. 1991.
    • (1991) Proc. Annual Meeting of the
    • Sumanaweera, T.S.1    Adler, J.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.