메뉴 건너뛰기




Volumn 39, Issue 4, 1992, Pages 1117-1121

Implementation and Evaluation of a Calculated Attenuation Correction for PET

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; DATA ACQUISITION; MEDICAL IMAGING;

EID: 0026901812     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/23.159770     Document Type: Article
Times cited : (57)

References (8)
  • 1
    • 0022665040 scopus 로고
    • Problems in Signal-to-Noise Ratio for Attenuation Correction in High Resolution PET
    • Dahlbom M, Hoffman EJ: Problems in Signal-to-Noise Ratio for Attenuation Correction in High Resolution PET. IEEE Trans Nucl Science NS-34:288-293, 1987.
    • (1987) IEEE Trans Nucl Science , vol.NS-34 , pp. 288-293
    • Dahlbom, M.1    Hoffman, E.J.2
  • 2
    • 0016631386 scopus 로고
    • Ter-Pogossian MM: Application of Annihilation Coincidence Detection to Transaxial Reconstruction Tomography
    • Phelps ME, Hoffman EJ, Mullani NA, Ter-Pogossian MM: Application of Annihilation Coincidence Detection to Transaxial Reconstruction Tomography. J Nucl Med 16(3):210-224, 1975.
    • (1975) J Nucl Med , vol.16 , Issue.3 , pp. 210-224
    • Phelps, M.E.1    Hoffman, E.J.2    Mullani, N.A.3
  • 3
    • 0018435637 scopus 로고
    • Corrections for Attenuation, Scattered Radiation and Random Coincidences in a Ring Detector Positron Emission Transaxial Tomograph
    • BergstrOm M, Bohm C, Ericson K. Eriksson L, Litton J: Corrections for Attenuation, Scattered Radiation and Random Coincidences in a Ring Detector Positron Emission Transaxial Tomograph. IEEE Trans Nucl Sci NS-27:549-554, 27:549-554, 1980.
    • (1980) IEEE Trans Nucl Sci , vol.NS-27 , pp. 549-554
    • BergstrOm, M.1    Bohm, C.2    Ericson, K.3    Eriksson, L.4    Litton, J.5
  • 4
    • 0020048935 scopus 로고
    • Blomqvist G: Determination of Object Contour from Projections for Attenuation Correction in Cranial Positron Emission Tomography
    • Bergstrom M, Litton J, Eriksson L, Bohm C, Blomqvist G: Determination of Object Contour from Projections for Attenuation Correction in Cranial Positron Emission Tomography. J Comput Assist Tomogr 6(2):365-372, 1982.
    • (1982) J Comput Assist Tomogr , vol.6 , Issue.2 , pp. 365-372
    • Bergstrom, M.1    Litton, J.2    Eriksson, L.3    Bohm, C.4
  • 5
    • 0024610834 scopus 로고
    • PET System Calibrations and Corrections for Quantitative and Spatially Accurate Images
    • Hoffman El, Guerrero TM, Germano G, Digby WM, Dahlbom M: PET System Calibrations and Corrections for Quantitative and Spatially Accurate Images. IEEE Trans Nucl Sci NS-36(1):1108-1112, 1989.
    • (1989) IEEE Trans Nucl Sci , vol.NS-36 , Issue.1 , pp. 1108-1112
    • Hoffman, E.L.1    Guerrero, T.M.2    Germano, G.3    Digby, W.M.4    Dahlbom, M.5
  • 6
    • 0022667556 scopus 로고
    • An Edge Detection Algorithm for Attenuation Correction in Emission CT
    • Tomitani T: An Edge Detection Algorithm for Attenuation Correction in Emission CT. IEEE Trans Nucl Sci NS-34(1):309-312, 1987. 34(1):309-312, 1987.
    • (1987) IEEE Trans Nucl Sci , vol.NS-34 , Issue.1 , pp. 309-312
    • Tomitani, T.1
  • 7
    • 0024341837 scopus 로고
    • Online brain attenuation correction in PET: towards a fully automated data handling in a clinical environment
    • Michel C, Bol A, De Volder AG, Goffinet AM: Online brain attenuation correction in PET: towards a fully automated data handling in a clinical environment. Eur J Nucl Med 15:712-718, 1989.
    • (1989) Eur J Nucl Med , vol.15 , pp. 712-718
    • Michel, C.1    Bol, A.2    De Volder, A.G.3    Goffinet, A.M.4
  • 8
    • 0025780950 scopus 로고
    • 3D PET using a Conventional Multislice Tomograph without Septa
    • Cherry SR, Dahlbom M, Hoffman EJ: 3D PET using a Conventional Multislice Tomograph without Septa, J Comput Assist Tomogr 15(4):655-668, 1991.
    • (1991) J Comput Assist Tomogr , vol.15 , Issue.4 , pp. 655-668
    • Cherry, S.R.1    Dahlbom, M.2    Hoffman, E.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.