메뉴 건너뛰기




Volumn 39, Issue 4, 1992, Pages 1088-1092

High Sensitivity, Total Body PET Scanning Using 3D Data Acquisition and Reconstruction

Author keywords

[No Author keywords available]

Indexed keywords

DATA ACQUISITION; IMAGE RECONSTRUCTION; SIGNAL TO NOISE RATIO;

EID: 0026900597     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/23.159765     Document Type: Article
Times cited : (15)

References (11)
  • 1
    • 0025414251 scopus 로고
    • Characterization of a whole body imaging technique for PET
    • T.M. Guerrero, E.J. Hoffman, M. Dahlbom, et al. “Characterization of a whole body imaging technique for PET”. IEEE Trans. Nucl. Sci., vol. NS-37, pp. 676–680, 1990.
    • (1990) IEEE Trans. Nucl. Sci , vol.NS-37 , pp. 676-680
    • Guerrero, T.M.1    Hoffman, E.J.2    Dahlbom, M.3
  • 2
    • 2742599598 scopus 로고
    • Total body and cross sectional imaging of the skeletal system with F-18 and PET
    • C.K. Hoh, R.A. Hawkins, M. Dahlbom, et al. “Total body and cross sectional imaging of the skeletal system with F-18 and PET.” J. Nucl. Med., vol. 31, pp. 780, 1990.
    • (1990) J. Nucl. Med , vol.31 , pp. 780
    • Hoh, C.K.1    Hawkins, R.A.2    Dahlbom, M.3
  • 3
    • 2742531485 scopus 로고
    • Total body imaging with fluorodeoxyglucose (FDG) and PET in patients with malignancies
    • C. Schiepers, R.A. Hawkins, C.K. Hoh, et al. “Total body imaging with fluorodeoxyglucose (FDG) and PET in patients with malignancies.” J. Nucl. Med., vol. 31, pp. 803, 1990.
    • (1990) J. Nucl. Med , vol.31 , pp. 803
    • Schiepers, C.1    Hawkins, R.A.2    Hoh, C.K.3
  • 6
    • 0025780950 scopus 로고
    • 3D PET using a conventional multislice tomograph without septa
    • S.R. Cherry, M. Dahlbom and E.J. Hoffman. “3D PET using a conventional multislice tomograph without septa.” J. Comput. Assist. Tomogr., vol. 15, pp. 655–668, 1991.
    • (1991) J. Comput. Assist. Tomogr , vol.15 , pp. 655-668
    • Cherry, S.R.1    Dahlbom, M.2    Hoffman, E.J.3
  • 7
    • 0026385161 scopus 로고
    • Fully three-dimensional reconstruction for a PET scanner with retractable septa
    • (in press)
    • D.W. Townsend, A. Geissbuhler, M. Defrise, et al. “Fully three-dimensional reconstruction for a PET scanner with retractable septa.” IEEE Trans. Med. Imag., 1992 (in press).
    • (1992) IEEE Trans. Med. Imag
    • Townsend, D.W.1    Geissbuhler, A.2    Defrise, M.3
  • 8
    • 0025131725 scopus 로고
    • Implementation of three-dimensional image reconstruction for multi-ring tomographs
    • M. Defuse, D.W. Townsend and A. Geissbuhler. “Implementation of three-dimensional image reconstruction for multi-ring tomographs.” Phys. Med. Biol., vol. 35, pp. 1361–1372, 1990.
    • (1990) Phys. Med. Biol , vol.35 , pp. 1361-1372
    • Defuse, M.1    Townsend, D.W.2    Geissbuhler, A.3
  • 9
    • 0026582130 scopus 로고
    • Evaluation of a 3D reconstruction algorithm for multi-slice PET scanners
    • (in press)
    • S.R. Cherry, M. Dahlbom and E.J. Hoffman, “Evaluation of a 3D reconstruction algorithm for multi-slice PET scanners.” Phys. Med. Biol., 1992 (in press).
    • (1992) Phys. Med. Biol
    • Cherry, S.R.1    Dahlbom, M.2    Hoffman, E.J.3
  • 10
    • 84939090229 scopus 로고
    • Performance of a neuroPET system employing 2-D modular detectors
    • E.J.- Hoffman, W.M. Digby, G. Germano, et al. “Performance of a neuroPET system employing 2-D modular detectors. J. Nucl. Med., vol. 29, pp. 983–4, 1988.
    • (1988) J. Nucl. Med , vol.29 , pp. 983-984
    • Hoffman, E.J.1    Digby, W.M.2    Germano, G.3
  • 11
    • 0026901812 scopus 로고
    • Implementation and evaluation of a calculated attenuation correction for PET
    • (submitted)
    • S. Siegel and M. Dahlbom. “Implementation and evaluation of a calculated attenuation correction for PET. IEEE Trans. Nucl. Sci., 1992 (submitted)
    • (1992) IEEE Trans. Nucl. Sci
    • Siegel, S.1    Dahlbom, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.