메뉴 건너뛰기




Volumn 39, Issue 6, 1992, Pages 558-562

Maximum-Likelihood Estimation of Current-Dipole Parameters for Data Obtained Using Multichannel Magnetometer

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL MATERIALS; COMPUTER SIMULATION; MAGNETIC FIELD MEASUREMENT; MAGNETOMETERS;

EID: 0026880583     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/10.141193     Document Type: Article
Times cited : (32)

References (13)
  • 2
    • 25544477988 scopus 로고
    • A 24-channel planar gradiometer: System design and analysis of neuromagnetic data
    • New York, Aug.
    • M. S. Hämäläinen, “A 24-channel planar gradiometer: System design and analysis of neuromagnetic data,” in Proc. Seventh Internat. Conf. Biomagnet., New York, Aug. 1989, pp. 639–644.
    • (1989) Proc. Seventh Internat. Conf. Biomagnet. , pp. 639-644
    • Hämäläinen, M.S.1
  • 3
    • 84941437533 scopus 로고
    • Localization of cortical function by analysis of multi-channel magnetic field recordings
    • K. C. Squires, S. Buchanan, and B. Schwartz, “Localization of cortical function by analysis of multi-channel magnetic field recordings,” J. Japan Biomagnetism Bioeleclromagnet. Soc, vol. 3, p. 159, 1990.
    • (1990) J. Japan Biomagnetism Bioeleclromagnet. Soc. , vol.3 , pp. 159
    • Squires, K.C.1    Buchanan, S.2    Schwartz, B.3
  • 4
    • 0022270336 scopus 로고
    • A comparison of moving dipole inverse solutions using EEG's and MEG's
    • B. N. Cuffin, “A comparison of moving dipole inverse solutions using EEG's and MEG's,” IEEE Trans. Biomed. Eng., vol. BME-32, pp. 905–910, 1985.
    • (1985) IEEE Trans. Biomed. Eng. , vol.BME-32 , pp. 905-910
    • Cuffin, B.N.1
  • 7
    • 0003650819 scopus 로고
    • Englewood Cliffs, NJ: Prentice-Hall
    • R. Deutsch, Estimation Theory. Englewood Cliffs, NJ: Prentice-Hall, 1965.
    • (1965) Estimation Theory
    • Deutsch, R.1
  • 9
    • 0025555714 scopus 로고
    • Parameter estimation of multiple biomagnetic current dipoles using simulated annealing
    • July San Diego, CA
    • K. Sekihara, H. Haneishi, and N. Ohyama, “Parameter estimation of multiple biomagnetic current dipoles using simulated annealing,” in Proc. SPIE Conf. Digital Image Synthesis Inverse Opt., vol. 1351, July 1990, San Diego, CA, pp. 410–416.
    • (1990) Proc. SPIE Conf. Digital Image Synthesis Inverse Opt. , vol.1351 , pp. 410-416
    • Sekihara, K.1    Haneishi, H.2    Ohyama, N.3
  • 10
    • 84927995724 scopus 로고
    • Rule-based location of multiple current-dipole sources from biomagnetic data
    • New York, Aug.
    • N. M. Palfreyman, K. D. Singh, and S. J. Swithenby. “Rule-based location of multiple current-dipole sources from biomagnetic data.” in Proc. Seventh Internal. Conf. Biomagnetism. New York, Aug. 1989. pp. 567–570.
    • (1989) Proc. Seventh Internal. Conf. Biomagnetism , pp. 567-570
    • Palfreyman, N.M.1    Singh, K.D.2    Swithenby, S.J.3
  • 11
    • 84933798052 scopus 로고
    • Discussion of biomagnetic imaging system and reconstruction algorithm
    • New York, Aug.
    • H. Haneishi, N. Ohyama, and K. Sekihara. “Discussion of biomagnetic imaging system and reconstruction algorithm,” in Proc. Seventh Internat. Conf. Biomagnet., New York, Aug. 1989, pp. 575– 578.
    • (1989) Proc. Seventh Internat. Conf. Biomagnet. , pp. 575-578
    • Haneishi, H.1    Ohyama, N.2    Sekihara, K.3
  • 12
    • 0001496394 scopus 로고
    • Environmental noise cancellation for biomagnetic measurements
    • New York, Aug.
    • S. E. Robinson, “Environmental noise cancellation for biomagnetic measurements,” in Proc. Seventh Internat. Conf. Biomagnet., New York, Aug. 1989, pp. 721–724.
    • (1989) Proc. Seventh Internat. Conf. Biomagnet. , pp. 721-724
    • Robinson, S.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.