메뉴 건너뛰기




Volumn 39, Issue 4, 1992, Pages 389-393

Supervisory Adaptive Control of Arterial Pressure During Cardiac Surgery

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL ENGINEERING--CARDIOLOGY; CONTROL SYSTEMS, ADAPTIVE; DRUG PRODUCTS--CONTROLLED DELIVERY; SODIUM COMPOUNDS;

EID: 0026848810     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/10.126611     Document Type: Article
Times cited : (27)

References (19)
  • 1
    • 0023396110 scopus 로고
    • An adaptive controller for closed-loop management of blood pressure in seriously ill patients
    • J. S. Packer, D. G. Mason, J. F. Cade, and S. M. McKinley, “An adaptive controller for closed-loop management of blood pressure in seriously ill patients,” IEEE Trans. Biomed. Eng., vol. BME-34, pp. 612–616, 1987.
    • (1987) IEEE Trans. Biomed. Eng. , vol.BME-34 , pp. 612-616
    • Packer, J.S.1    Mason, D.G.2    Cade, J.F.3    McKinley, S.M.4
  • 3
    • 0021947018 scopus 로고
    • Computer controlled regulation of sodium nitroprusside infusion
    • L. J. Meline, D. R. Westenskow, N. L. Pace, and M. N. Bodily, “Computer controlled regulation of sodium nitroprusside infusion,” Anesth. Analg., vol. 64, pp. 38–42, 1985.
    • (1985) Anesth. Analg. , vol.64 , pp. 38-42
    • Meline, L.J.1    Westenskow, D.R.2    Pace, N.L.3    Bodily, M.N.4
  • 4
    • 0019623438 scopus 로고
    • Microprocessor-based controller for pharmacodynamical applications
    • A. J. Koivo, “Microprocessor-based controller for pharmacodynamical applications,” IEEE Trans. Automat. Contr., vol. AC-26, pp. 1208–1213, 1981.
    • (1981) IEEE Trans. Automat. Contr. , vol.AC-26 , pp. 1208-1213
    • Koivo, A.J.1
  • 6
    • 0022361683 scopus 로고
    • The self-tuning controller: Comparison with human performance in the control of arterial pressure
    • K. S. Stern, H. J. Chizek, B. K. Walker, P. S. Krishnaprasad, P. J. Dauchot, and P. G. Katona, “The self-tuning controller: Comparison with human performance in the control of arterial pressure,” Ann. Biomed. Eng., vol. 13, pp. 341–357, 1985.
    • (1985) Ann. Biomed. Eng. , vol.13 , pp. 341-357
    • Stern, K.S.1    Chizek, H.J.2    Walker, B.K.3    Krishnaprasad, P.S.4    Dauchot, P.J.5    Katona, P.G.6
  • 7
    • 0021389448 scopus 로고
    • Model reference adaptive control of drug infusion rate
    • H. Kaufman, R. Roy, and X. Xu, “Model reference adaptive control of drug infusion rate,” Automatica, vol. 20, pp. 205–209, 1984.
    • (1984) Automatica , vol.20 , pp. 205-209
    • Kaufman, H.1    Roy, R.2    Xu, X.3
  • 8
    • 0025457072 scopus 로고
    • Model reference adaptive control with constraints for postoperative blood pressure management
    • G. A. Pajunen, M. Steinmetz, and R. Shankar, “Model reference adaptive control with constraints for postoperative blood pressure management,” IEEE Trans. Biomed. Eng., vol. BME-37, pp. 679–687, 1990.
    • (1990) IEEE Trans. Biomed. Eng. , vol.BME-37 , pp. 679-687
    • Pajunen, G.A.1    Steinmetz, M.2    Shankar, R.3
  • 9
    • 0022558012 scopus 로고
    • Multiple model adaptive control procedure for blood pressure control
    • W. G. He, H. Kaufman, and R. Roy, “Multiple model adaptive control procedure for blood pressure control,” IEEE Trans. Biomed. Eng., vol. BME-33, pp. 10–19, 1986.
    • (1986) IEEE Trans. Biomed. Eng. , vol.BME-33 , pp. 10-19
    • He, W.G.1    Kaufman, H.2    Roy, R.3
  • 10
    • 0023526533 scopus 로고
    • Multiple-model adaptive control of blood pressure using sodium nitroprusside
    • J. F. Martin, A. M. Schneider, and N. T. Smith, “Multiple-model adaptive control of blood pressure using sodium nitroprusside,” IEEE Trans. Biomed. Eng., vol. BME-34, pp. 603–611, 1987.
    • (1987) IEEE Trans. Biomed. Eng. , vol.BME-34 , pp. 603-611
    • Martin, J.F.1    Schneider, A.M.2    Smith, N.T.3
  • 11
    • 0023526536 scopus 로고
    • Adaptive multivariable drug delivery control of arterial pressure and cardiac output in anesthetized dogs
    • G. I. Voss, P. G. Katona, and H. J. Chizek, “Adaptive multivariable drug delivery control of arterial pressure and cardiac output in anesthetized dogs,” IEEE Trans. Biomed. Eng., vol. BME-34, pp. 617–623, 1987.
    • (1987) IEEE Trans. Biomed. Eng. , vol.BME-34 , pp. 617-623
    • Voss, G.I.1    Katona, P.G.2    Chizek, H.J.3
  • 12
    • 0026848966 scopus 로고
    • Improved safety and efficacy in adaptive control of arterial blood pressure through the use of a supervisor
    • J. F. Martin, A. M. Schneider, M. L. Quinn, and M. T. Smith, “Improved safety and efficacy in adaptive control of arterial blood pressure through the use of a supervisor,” IEEE Trans. Biomed. Eng., vol. 39, 1992.
    • (1992) IEEE Trans. Biomed. Eng. , vol.39
    • Martin, J.F.1    Schneider, A.M.2    Quinn, M.L.3    Smith, M.T.4
  • 13
    • 0019273287 scopus 로고
    • Computer control of the infusion of vasoactive drugs
    • L. C. Sheppard, “Computer control of the infusion of vasoactive drugs,” Ann. Biomed. Eng., vol. 8, pp. 431–444, 1980.
    • (1980) Ann. Biomed. Eng. , vol.8 , pp. 431-444
    • Sheppard, L.C.1
  • 14
    • 0024372368 scopus 로고
    • Automated control of postoperative hypertension: A prospective randomized multicenter study
    • D. M. Cosgrove, J. H. Petre, J. L. Waller, J. V. Roth, C. Shepherd, and L. H. Cohn, “Automated control of postoperative hypertension: A prospective randomized multicenter study,” Ann. Thorac. Surg., vol. 47, pp. 678–683, 1989.
    • (1989) Ann. Thorac. Surg. , vol.47 , pp. 678-683
    • Cosgrove, D.M.1    Petre, J.H.2    Waller, J.L.3    Roth, J.V.4    Shepherd, C.5    Cohn, L.H.6
  • 15
    • 8644232913 scopus 로고
    • Automatic control of arterial pressure in the operating room: safety during episodes of artifact and hypotension
    • M. L. Quinn, N. T. Smith, J. E. Mandel, J. F. Martin, and A. M. Schneider, “Automatic control of arterial pressure in the operating room: safety during episodes of artifact and hypotension,” Anesthesiol., vol. 69, p. A327, 1988.
    • (1988) Anesthesiol. , vol.69 , pp. A327
    • Quinn, M.L.1    Smith, N.T.2    Mandel, J.E.3    Martin, J.F.4    Schneider, A.M.5
  • 19
    • 0025562860 scopus 로고
    • Identification of patient sensitivity, baseline pressure, and infusion delay using fast spectral estimates during closed-loop control of mean arterial pressure
    • D. T. Johnson, A. M. Schneider, J. F. Martin, and M. L. Quinn, “Identification of patient sensitivity, baseline pressure, and infusion delay using fast spectral estimates during closed-loop control of mean arterial pressure,” in Proc. 12th Ann. Conf. IEEE Eng. Med. Biol. Soc., 1990.
    • (1990) Proc. 12th Ann. Conf. IEEE Eng. Med. Biol. Soc.
    • Johnson, D.T.1    Schneider, A.M.2    Martin, J.F.3    Quinn, M.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.