Volumn 16, Issue 5, 1992, Pages 804-813

Performance evaluation of the positron scanner ecat exact

Author keywords

Apparatus and equipment; Emission computed tomography; Performance evaluation; Techniques

Indexed keywords

FLUORODEOXYGLUCOSE;

EID: 0026802021     PISSN: 03638715     EISSN: 15323145     Source Type: Journal    
DOI: 10.1097/00004728-199209000-00024     Document Type: Article
Times cited : (213)

References (12)
  • 1
    • 84939045331 scopus 로고
    • A multicrystal two dimensional BGO detector system for positron emission tomography
    • Casey ME, Nutt R. A multicrystal two dimensional BGO detector system for positron emission tomography. IEEE Trans Nucl Sci 1986;33:460-3.
    • (1986) IEEE Trans Nucl Sci , vol.33 , pp. 460-463
    • Casey, M.E.1    Nutt, R.2
  • 2
    • 84910864831 scopus 로고
    • Figures of merit for different detector configurations utilized in high resolution positron cameras
    • Eriksson L, Bergström M, Bohm C, Holte S, Kesselberg M, Litton J. Figures of merit for different detector configurations utilized in high resolution positron cameras. IEEE Trans Nucl Sci 1986;33:446-51.
    • (1986) IEEE Trans Nucl Sci , vol.33 , pp. 446-451
    • Eriksson, L.1    Bergström, M.2    Bohm, C.3    Holte, S.4    Kesselberg, M.5    Litton, J.6
  • 4
    • 0024611408 scopus 로고
    • Coincidence detection and selection in positron emission tomography using VLSI
    • Newport DF, Dent HM, Casey ME, Bouldin DW. Coincidence detection and selection in positron emission tomography using VLSI. IEEE Trans Nucl Sci 1989;36:1052-5.
    • (1989) IEEE Trans Nucl Sci , vol.36 , pp. 1052-1055
    • Newport, D.F.1    Dent, H.M.2    Casey, M.E.3    Bouldin, D.W.4
  • 5
    • 2042453268 scopus 로고
    • A VMEBUS based, real time sorter design for positron emission tomography
    • Jones WF, Casey ME, Byars LG, Burgiss SG. A VMEBUS based, real time sorter design for positron emission tomography. IEEE Trans Nucl Sci 1986;33:601-4.
    • (1986) IEEE Trans Nucl Sci , vol.33 , pp. 601-604
    • Jones, W.F.1    Casey, M.E.2    Byars, L.G.3    Burgiss, S.G.4
  • 6
    • 0020660172 scopus 로고
    • Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections
    • Bergström M, Eriksson L, Bohm C, Blomqvist G, Litton J. Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections. J Corn-put Assist Tomogr 1983;7:42-50.
    • (1983) J Corn-Put Assist Tomogr , vol.7 , pp. 42-50
    • Bergström, M.1    Eriksson, L.2    Bohm, C.3    Blomqvist, G.4    Litton, J.5
  • 8
    • 0019525907 scopus 로고
    • A four ring positron camera system for emission tomography of the brain
    • Eriksson L, Bohm C, Kesselberg M, et al. A four ring positron camera system for emission tomography of the brain. IEEE Trans Nucl Sci 1982;29:539-43.
    • (1982) IEEE Trans Nucl Sci , vol.29 , pp. 539-543
    • Eriksson, L.1    Bohm, C.2    Kesselberg, M.3
  • 9
    • 33748251685 scopus 로고
    • Performance characteristics of the latest generation of commercial positron scanner
    • Spinks TJ, Jones T, Gilardi MC, Heather JD. Performance characteristics of the latest generation of commercial positron scanner. IEEE Trans Nucl Sci 1988;35:721-5.
    • (1988) IEEE Trans Nucl Sci , vol.35 , pp. 721-725
    • Spinks, T.J.1    Jones, T.2    Gilardi, M.C.3    Heather, J.D.4
  • 10
    • 0026384823 scopus 로고
    • Physical characteristics of the ECAT 953/B31: A new high resolution brain positron tomograph
    • Mazoyer B, Trebossen R, Deutch R, Casey M, Blohm K. Physical characteristics of the ECAT 953/B31: a new high resolution brain positron tomograph. IEEE Trans Med Sci 1991;10:499-504.
    • (1991) IEEE Trans Med Sci , vol.10 , pp. 499-504
    • Mazoyer, B.1    Trebossen, R.2    Deutch, R.3    Casey, M.4    Blohm, K.5
  • 11
    • 0343316309 scopus 로고
    • Physical performance of a new commercial positron tomograph with retractable septa
    • Spinks TJ, Jones T, Bailey DL, et al. Physical performance of a new commercial positron tomograph with retractable septa. IEEE Med Imaging Conf Rec, 1991, 1313-7.
    • (1991) IEEE Med Imaging Conf Rec , pp. 1313-1317
    • Spinks, T.J.1    Jones, T.2    Bailey, D.L.3
  • 12
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: Relating count rates to image signal-to-noise ratio using noise equivalent counts
    • Strother SC, Casey ME, Hoffman EJ. Measuring PET scanner sensitivity: relating count rates to image signal-to-noise ratio using noise equivalent counts. IEEE Trans Nucl Sci 1990;37:783-8.
    • (1990) IEEE Trans Nucl Sci , vol.37 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.