메뉴 건너뛰기




Volumn 13, Issue 6, 1992, Pages 789-793

Oxygen consumption during corridor walk testing in chronic cardiac failure

Author keywords

Corridor walk test; Exercise testing; Heart failure

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; DISEASE CLASSIFICATION; EXERCISE TEST; FEMALE; HEART FAILURE; HUMAN; MALE; OXYGEN CONSUMPTION; PRIORITY JOURNAL; REPRODUCIBILITY; WALKING;

EID: 0026753696     PISSN: 0195668X     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.eurheartj.a060258     Document Type: Article
Times cited : (101)

References (16)
  • 2
    • 0022355747 scopus 로고
    • Lactate production during maximal and submaximal exercise in patients with chronic heart failure
    • Weber KT, Janicki JS, Simonton CA, Higginbotham MB, Cobb FR. Lactate production during maximal and submaximal exercise in patients with chronic heart failure. J Am Coll Cardiol 1985; 6: 717-24.
    • (1985) J Am Coll Cardiol , vol.6 , pp. 717-724
    • Weber, K.T.1    Janicki, J.S.2    Simonton, C.A.3    Higginbotham, M.B.4    Cobb, F.R.5
  • 3
    • 0022004473 scopus 로고
    • Respiratory gas exchange in the assessment of patients with left ventricular dysfunction
    • Lipkin DP, Perrins J, Poole-Wilson PA. Respiratory gas exchange in the assessment of patients with left ventricular dysfunction. Br Heart J 1985; 54: 321-8.
    • (1985) Br Heart J , vol.54 , pp. 321-328
    • Lipkin, D.P.1    Perrins, J.2    Poole-Wilson, P.A.3
  • 4
    • 0017261263 scopus 로고
    • Twelve-minute walking test for assessing disability in chronic bronchitis
    • McGavin CR, Gupta SP, McHardy GJR. Twelve-minute walking test for assessing disability in chronic bronchitis. Br Med J 1976; 1: 822-3.
    • (1976) Br Med J , vol.1 , pp. 822-823
    • McGavin, C.R.1    Gupta, S.P.2    McHardy, G.J.R.3
  • 6
    • 0022632948 scopus 로고
    • Six minute walking test for assessing exercise capacity in chronic heart failure
    • Lipkin DP, Scriven AJ, Crake T, Poole-Wilson PA. Six minute walking test for assessing exercise capacity in chronic heart failure. Br Med J 1986; 292: 653-5.
    • (1986) Br Med J , vol.292 , pp. 653-655
    • Lipkin, D.P.1    Scriven, A.J.2    Crake, T.3    Poole-Wilson, P.A.4
  • 7
    • 0021166027 scopus 로고
    • The reproducibility of hemodynamic, electro-cardiographic, and gas exchange data during treadmill exercise in patients with stable angina pectoris
    • Sullivan M, Center F, Savvides M, Roberts M, Myers J, Froelicher VF. The reproducibility of hemodynamic, electro-cardiographic, and gas exchange data during treadmill exercise in patients with stable angina pectoris. Chest 1984; 86: 375-82.
    • (1984) Chest , vol.86 , pp. 375-382
    • Sullivan, M.1    Center, F.2    Savvides, M.3    Roberts, M.4    Myers, J.5    Froelicher, V.F.6
  • 8
    • 0025129209 scopus 로고
    • Reproducibility of cardiopulmonary parameters during exercise in patients with chronic cardiac failure. the need for a preliminary test
    • Elborn JS, Stanford CF, Nicholls DP. Reproducibility of cardiopulmonary parameters during exercise in patients with chronic cardiac failure. The need for a preliminary test. Eur Heart J 1990; 11: 75-81.
    • (1990) Eur Heart J , vol.11 , pp. 75-81
    • Elborn, J.S.1    Stanford, C.F.2    Nicholls, D.P.3
  • 9
    • 0020626789 scopus 로고
    • Determination of anaerobic threshold for assessment of functional state in patients with chronic heart failure
    • Matsumara N, Nishijima H, Kojima S, Hashimoto F, Minami M, Yasuda H. Determination of anaerobic threshold for assessment of functional state in patients with chronic heart failure. Circulation 1983; 68: 360-7.
    • (1983) Circulation , vol.68 , pp. 360-367
    • Matsumara, N.1    Nishijima, H.2    Kojima, S.3    Hashimoto, F.4    Minami, M.5    Yasuda, H.6
  • 10
    • 0023250464 scopus 로고
    • The Oxylog oxygen consumption meter: A portable device for measurement of energy expenditure
    • McNeill G, Cox MD, Rivers JPW. The Oxylog oxygen consumption meter: a portable device for measurement of energy expenditure. Am J Clin Nutr 1987; 45: 1415-9.
    • (1987) Am J Clin Nutr , vol.45 , pp. 1415-1419
    • McNeill, G.1    Cox, M.D.2    Rivers, J.P.W.3
  • 11
    • 0024438848 scopus 로고
    • The influence of different methods on basal metabolic rate measurements in human subjects
    • Soares MJ, Sheela ML, Kurpad AV, Kulkarni RL, Shelly PS. The influence of different methods on basal metabolic rate measurements in human subjects. Am J Clin Nutr 1989; 50: 731-6.
    • (1989) Am J Clin Nutr , vol.50 , pp. 731-736
    • Soares, M.J.1    Sheela, M.L.2    Kurpad, A.V.3    Kulkarni, R.L.4    Shelly, P.S.5
  • 12
    • 0025346317 scopus 로고
    • Comparison of a face-mask and a mouthpiece for measuring resting energy expenditure with the 'Oxylog'
    • Bukkens SG, McNeill G. Comparison of a face-mask and a mouthpiece for measuring resting energy expenditure with the 'Oxylog'. Ann Nutr Metab 1990; 34: 112-8.
    • (1990) Ann Nutr Metab , vol.34 , pp. 112-118
    • Bukkens, S.G.1    McNeill, G.2
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i: 307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 16
    • 0022540052 scopus 로고
    • Use of maximal bicycle exercise testing with respiratory gas analysis to assess exercise performance in patients with congestive heart failure secondary to coronary artery disease or to idiopathic dilated cardiomyopathy
    • Wilson JR, Fink LI, Ferraro N, Dunkman WB, Jones RA. Use of maximal bicycle exercise testing with respiratory gas analysis to assess exercise performance in patients with congestive heart failure secondary to coronary artery disease or to idiopathic dilated cardiomyopathy. Am J Cardiol 1986; 58: 601-6.
    • (1986) Am J Cardiol , vol.58 , pp. 601-606
    • Wilson, J.R.1    Fink, L.I.2    Ferraro, N.3    Dunkman, W.B.4    Jones, R.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.