메뉴 건너뛰기




Volumn 13, Issue 9, 1992, Pages 1164-1172

The European ST-T database: Standard for evaluating systems for the analysis of ST-T changes in ambulatory electrocardiography

Author keywords

Annotated ECG database; Myocardial ischaemia; Performance evaluation of instrumentation; ST T change analysis

Indexed keywords

ALGORITHM; AMBULATORY MONITORING; ARTICLE; DATA BASE; ELECTROCARDIOGRAPHY MONITORING; EUROPEAN UNION; HEART MUSCLE ISCHEMIA; INTERNATIONAL STANDARD UNIT; PRIORITY JOURNAL; QRS COMPLEX; QUALITY CONTROL; ST SEGMENT; T WAVE;

EID: 0026705255     PISSN: 0195668X     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.eurheartj.a060332     Document Type: Article
Times cited : (326)

References (13)
  • 1
    • 0022039360 scopus 로고
    • Recommendations for standard of instrumentation and practice in the use of Ambulatory Electrocardiography
    • Sheffield LT, Berson A, Bragg-Remschel D et al. Recommendations for standard of instrumentation and practice in the use of Ambulatory Electrocardiography. Circulation 1985; 71: 626A-36A.
    • (1985) Circulation , vol.71
    • Sheffield, L.T.1    Berson, A.2    Bragg-Remschel, D.3
  • 2
    • 0024535353 scopus 로고
    • Guidelines for Ambulatory Electrocardiography
    • Knoebel SB, Crawford MH, Dunn MI et al. Guidelines for Ambulatory Electrocardiography. Circulation 1989; 79: 206-15.
    • (1989) Circulation , vol.79 , pp. 206-215
    • Knoebel, S.B.1    Crawford, M.H.2    Dunn, M.I.3
  • 3
    • 0025304081 scopus 로고
    • Ambulant myocardial ischemia and its prognostic implications
    • Pepine CJ. Ambulant myocardial ischemia and its prognostic implications. Circulation 1990; 81: 1136-8.
    • (1990) Circulation , vol.81 , pp. 1136-1138
    • Pepine, C.J.1
  • 4
    • 0025321562 scopus 로고
    • Silent ischemia during daily life is an independent predictor of mortality in stable angina
    • Deedwania PC, Carbajal EV. Silent ischemia during daily life is an independent predictor of mortality in stable angina. Circulation 1990; 81: 748-56.
    • (1990) Circulation , vol.81 , pp. 748-756
    • Deedwania, P.C.1    Carbajal, E.V.2
  • 5
    • 0022716454 scopus 로고
    • The European Community concerted action on Ambulatory Monitoring
    • Marchesi C. The European Community concerted action on Ambulatory Monitoring. J Med Eng Techn 1986; 10: 131-4.
    • (1986) J Med Eng Techn , vol.10 , pp. 131-134
    • Marchesi, C.1
  • 6
    • 0020997227 scopus 로고
    • An annotated database for the evaluation of algorithms for the analysis of arrhythmias and ischemic events
    • Taddei A, Varanini M, Macerata A et al. An annotated database for the evaluation of algorithms for the analysis of arrhythmias and ischemic events. Com Cardiol 1983; 10: 191-4.
    • (1983) Com Cardiol , vol.10 , pp. 191-194
    • Taddei, A.1    Varanini, M.2    Macerata, A.3
  • 7
    • 0023457777 scopus 로고
    • ST-T change analysis in ECG ambulatory monitoring: A European standard for performance evaluation
    • Taddei A, Benassi A, Biagini A et al. ST-T change analysis in ECG ambulatory monitoring: a European standard for performance evaluation. Com Cardiol 1988; 14: 63-8.
    • (1988) Com Cardiol , vol.14 , pp. 63-68
    • Taddei, A.1    Benassi, A.2    Biagini, A.3
  • 8
    • 0024720955 scopus 로고
    • An annotated database aimed at performance evaluation of algorithms for ST-T change analysis
    • Taddei A, Biagini A, Distante G et al. An annotated database aimed at performance evaluation of algorithms for ST-T change analysis. Com Cardiol 1990; 16: 117-20.
    • (1990) Com Cardiol , vol.16 , pp. 117-120
    • Taddei, A.1    Biagini, A.2    Distante, G.3
  • 9
    • 0004727476 scopus 로고
    • Evaluation of automated arrhythmia monitors using an annotated ECG database
    • Marchesi C, ed. The Hague: Martinus Nijoff Publ.
    • Mark RG, Moody GB. Evaluation of automated arrhythmia monitors using an annotated ECG database. In: Marchesi C, ed. Ambulatory Monitoring. The Hague: Martinus Nijoff Publ. 1984: 339-57.
    • (1984) Ambulatory Monitoring , pp. 339-357
    • Mark, R.G.1    Moody, G.B.2
  • 10
    • 0004254082 scopus 로고    scopus 로고
    • MIT-BIH Database Distribution, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Room 20A-113, Cambridge, MA 02139 U.S.A
    • MIT-BIH Arrhythmia Database. Available from: MIT-BIH Database Distribution, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Room 20A-113, Cambridge, MA 02139 U.S.A.
    • MIT-BIH Arrhythmia Database
  • 11
    • 0019280139 scopus 로고
    • Development, distribution and use of the AHA database for ventricular arrhythmia detector evaluation
    • Hermes RE, Geselowitz DB, Oliver GC et al. Development, distribution and use of the AHA database for ventricular arrhythmia detector evaluation. Com Cardiol 1981; 7: 263-6.
    • (1981) Com Cardiol , vol.7 , pp. 263-266
    • Hermes, R.E.1    Geselowitz, D.B.2    Oliver, G.C.3
  • 12
    • 85033629944 scopus 로고    scopus 로고
    • AHA database distributor: Emergency Care Research Institute, 5200 Butler Pike, Plymouth Meeting, Pennsylvania 19462, U.S.A.
    • AHA database distributor: Emergency Care Research Institute, 5200 Butler Pike, Plymouth Meeting, Pennsylvania 19462, U.S.A.
  • 13
    • 78751635334 scopus 로고    scopus 로고
    • Available from: ST-T Database Distribution, Institute of Clinical Physiology, Computer Laboratory (A. Taddei), via Trieste n.41, 56100 Pisa, Italy.
    • European ST-T Database. Available from: ST-T Database Distribution, Institute of Clinical Physiology, Computer Laboratory (A. Taddei), via Trieste n.41, 56100 Pisa, Italy.
    • European ST-T Database


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.