Volumn 10, Issue 4, 1991, Pages 523-529

A Computer-Assisted System for 3-D Frameless Localization in Stereotaxic MRI

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL ENGINEERING - NEUROSURGERY; COMPUTER SIMULATION; MATHEMATICAL TECHNIQUES - MATRIX ALGEBRA;

EID: 0026370529     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/42.108586     Document Type: Article
Times cited : (24)

References (19)
  • 2
    • 0018735228 scopus 로고
    • A stereotaxic head frame for use with CT body scanners
    • July-Aug.
    • R. A. Brown, “A stereotaxic head frame for use with CT body scanners,” Invest. Radiol., vol. 14, pp. 300–304, July-Aug. 1979.
    • (1979) Invest. Radiol , vol.14 , pp. 300-304
    • Brown, R.A.1
  • 3
    • 0023574352 scopus 로고
    • Coordinate transformations and calculation of the angular and depth parameters for a stereotactic system
    • Nov-Dec.
    • C. B. Saw, K. Ayyangar, and N. Suntharalingam, “Coordinate transformations and calculation of the angular and depth parameters for a stereotactic system,” Med. Phys., vol. 14, no. 6, pp. 1042–1044, Nov-Dec. 1987.
    • (1987) Med. Phys , vol.14 , Issue.6 , pp. 1042-1044
    • Saw, C.B.1    Ayyangar, K.2    Suntharalingam, N.3
  • 4
    • 46149140661 scopus 로고
    • System analysis of stereotactic neurosurgery based on CT scans
    • Y. Lirov and M. Vannier, “System analysis of stereotactic neurosurgery based on CT scans,” Comput. Math. Appl., vol. 12A, no. 7, pp. 839–858, 1986.
    • (1986) Comput. Math. Appl , vol.12A , Issue.7 , pp. 839-858
    • Lirov, Y.1    Vannier, M.2
  • 5
    • 0022645636 scopus 로고
    • Stereotaxic biopsy of the brain under MR imaging control
    • Jan-Feb.
    • D. G. T. Thomas, C. H. Davis, S. Ingram, J. S. Olney, C. M. Bydder, and I. R. Young, “Stereotaxic biopsy of the brain under MR imaging control,” AJNR, vol. 7, pp. 161–163, Jan-Feb. 1986.
    • (1986) AJNR , vol.7 , pp. 161-163
    • Thomas, D.G.T.1    Davis, C.H.2    Ingram, S.3    Olney, J.S.4    Bydder, C.M.5    Young, I.R.6
  • 8
    • 0021646662 scopus 로고
    • Stereotaxic device for polar approaches in orthogonal systems
    • Dec.
    • M. Scerrati, A. Fiorentino, M. Fiorentino, and P. Pola, “Stereotaxic device for polar approaches in orthogonal systems,” J. Neurosurg., vol. 61, pp. 1146–1147, Dec. 1984.
    • (1984) J. Neurosurg , vol.61 , pp. 1146-1147
    • Scerrati, M.1    Fiorentino, A.2    Fiorentino, M.3    Pola, P.4
  • 9
    • 0023186402 scopus 로고
    • Correction of spatial distorsion in MR imaging: A prerequisite for accurate stereotaxy
    • L. Schad, S. Lott, F. Schmitt, V. Sturm, and W. J. Lorenz, “Correction of spatial distorsion in MR imaging: A prerequisite for accurate stereotaxy,” J. Comput. Assist. Tomograph., vol. 11, no. 3, pp. 499–505, 1987.
    • (1987) J. Comput. Assist. Tomograph , vol.11 , Issue.3 , pp. 499-505
    • Schad, L.1    Lott, S.2    Schmitt, F.3    Sturm, V.4    Lorenz, W.J.5
  • 11
    • 0024517164 scopus 로고
    • Stereotactic radiosurgery with the linear accelerator: Treatment of arteriovenous malformations
    • O. Betti, C. Munari, and R. Rosler, “Stereotactic radiosurgery with the linear accelerator: Treatment of arteriovenous malformations,” Neurosurg., vol. 24, no. 3, pp. 311–321, 1989.
    • (1989) Neurosurg , vol.24 , Issue.3 , pp. 311-321
    • Betti, O.1    Munari, C.2    Rosler, R.3
  • 12
    • 0024357627 scopus 로고
    • A computerized adjustable brain atlas
    • C. Bohm, T. Greitz, and L. Eriksson, “A computerized adjustable brain atlas,” Europ. J. Nucl. Med., vol. 15, pp. 687–689, 1989.
    • (1989) Europ. J. Nucl. Med , vol.15 , pp. 687-689
    • Bohm, C.1    Greitz, T.2    Eriksson, L.3
  • 13
    • 0023587778 scopus 로고
    • Automated stereotactic positioning system
    • S. J. Goerss, P. J. Kelly, and B. A. Kali, “Automated stereotactic positioning system,” Appl. Neurophysiol., vol. 50, pp. 100–106, 1987.
    • (1987) Appl. Neurophysiol , vol.50 , pp. 100-106
    • Goerss, S.J.1    Kelly, P.J.2    Kali, B.A.3
  • 14
    • 84936897326 scopus 로고
    • Computer-driven robot for stereotactic surgery connected to CT scan and magnetic resonance imaging
    • A. L. Benabid, Ph. Cinquin, S. Lavallée, J. F. Le Bas, J. Demongeot, and J. de Rougemont, “Computer-driven robot for stereotactic surgery connected to CT scan and magnetic resonance imaging,” Appl. Neurophysiol., vol. 50, pp. 153–154, 1987.
    • (1987) Appl. Neurophysiol , vol.50 , pp. 153-154
    • Benabid, A.L.1    Cinquin, P.2    Lavallae, S.3    Le Bas, J.F.4    Demongeot, J.5    de Rougemont, J.6
  • 15
    • 84910713529 scopus 로고
    • Comprehensive computer-assisted data collection treatment planning and interactive surgery
    • B. A. Kall, P. J. Kelly, and S. J. Goerss, “Comprehensive computer-assisted data collection treatment planning and interactive surgery,” SPIE Med. Imaging, vol. 767, pp. 509–514, 1987.
    • (1987) SPIE Med. Imaging , vol.767 , pp. 509-514
    • Kall, B.A.1    Kelly, P.J.2    Goerss, S.J.3
  • 19
    • 84941506866 scopus 로고
    • New York/London: Wiley,
    • Ralston and Wilf, Mathematical Methods for Digital Computers. New York/London: Wiley, 1960.
    • (1960) Ralston and Wilf


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.