메뉴 건너뛰기




Volumn 38, Issue 5, 1991, Pages 510-520

Experimental Evaluation of a Prototype Cylindrical Section Ultrasound Hyperthermia Phased-Array Applicator

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL ENGINEERING--HYPERTHERMIA THERAPY; BIOMEDICAL EQUIPMENT; CYLINDERS--MEDICAL APPLICATIONS;

EID: 0026220889     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/58.84298     Document Type: Article
Times cited : (39)

References (13)
  • 1
    • 0003254607 scopus 로고
    • Physical aspects and clinical studies with ultrasonic hyperthermia
    • F. Storm. Ed. Boston: G. K. Hall Medical Publishers
    • P. Lele, “Physical aspects and clinical studies with ultrasonic hyperthermia,” in Hyperthermia in Cancer Therapy, F. Storm. Ed. Boston: G. K. Hall Medical Publishers, 1983.
    • (1983) Hyperthermia in Cancer Therapy
    • Lele, P.1
  • 2
    • 0023102506 scopus 로고
    • A scanned, focused, multiple transducer ultrasonic system for localized hyperthermia treatments
    • K. Hynenen et al., “A scanned, focused, multiple transducer ultrasonic system for localized hyperthermia treatments,” Int. J. Hyperthermia. vol. 3, no. 1, pp. 21–35, 1987.
    • (1987) Int. J. Hyperthermia. , vol.3 , Issue.1 , pp. 21-35
    • Hynenen, K.1
  • 3
    • 84939720990 scopus 로고
    • Localized deep heating in soft tissue environments with a multiple overlapping beam ultrasonic hyperthermia system
    • New Orleans, LA
    • G. Nussbaum et al., “Localized deep heating in soft tissue environments with a multiple overlapping beam ultrasonic hyperthermia system.” (Abstract only) 10th Ann. Meeting North Arner. Hyperthermia Group, New Orleans, LA, 1990.
    • (1990) (Abstract only) 10th Ann. Meeting North Arner. Hyperthermia Group
    • Nussbaum, G.1
  • 4
    • 84939769219 scopus 로고    scopus 로고
    • The threshold for thermally significant cavitation in dog's thigh muscle in vivo
    • K. Hynynen, “The threshold for thermally significant cavitation in dog's thigh muscle in vivo,” submitted to Ultrasound in Medicine and Biology.
    • submitted to Ultrasound in Medicine and Biology
    • Hynynen, K.1
  • 5
    • 0024068735 scopus 로고
    • A cylindrical-section ultrasound phased-array applicator for hyperthermia cancer therapy
    • E. Ebbini, S. Umemura, M. Ibbini, and C. Cain, “A cylindrical-section ultrasound phased-array applicator for hyperthermia cancer therapy,” IEEE Trans., Ultra son. Ferroelec. Freq. Contr. 35, no. 5, pp. 561-572. 1988.
    • (1988) IEEE Trans. Ultra son. Ferroelec. Freq. Contr , vol.35 , Issue.5 , pp. 561-572
    • Ebbini, E.1    Umemura, S.2    Ibbini, M.3    Cain, C.4
  • 6
    • 0003787517 scopus 로고
    • Deep localized hyperthermia with ultrasound phased arrays using the pseudoinverse pattern synthesis method
    • E. S. Ebbini, “Deep localized hyperthermia with ultrasound phased arrays using the pseudoinverse pattern synthesis method,” Ph. D. Dissertation, Univ. L Urbana, 1990.
    • (1990) Ph. D. Dissertation, Univ. L Urbana
    • Ebbini, E.S.1
  • 7
    • 0022721275 scopus 로고
    • Concentric-ring and scctor-vortcx phased-array applicators for ultrasound hyperthermia
    • C. Cain and S. Umemura, “Concentric-ring and scctor-vortcx phased-array applicators for ultrasound hyperthermia” IEEE Trans. Microwave Theory Tech., vol. MTT-34. no. 5. pp. 542–551, 1986.
    • (1986) IEEE Trans. Microwave Theory Tech. , vol.MTT-34 , Issue.5 , pp. 542-551
    • Cain, C.1    Umemura, S.2
  • 8
    • 0026189256 scopus 로고
    • A spherical-section ultrasound phased array applicator for deep localized hyperthermia
    • E. Ebbini and C. Cain, “A spherical-section ultrasound phased array applicator for deep localized hyperthermia,” IEEE Trans. Bromed. Eng., vol. 38, pp. 634-643, July 1987.
    • (1987) IEEE Trans. Bromed. Eng. , vol.38 , pp. 634-643, July
    • Ebbini, E.1    Cain, C.2
  • 9
    • 0024739554 scopus 로고
    • Multiplc-focus ultrasound phased-array pattern synthesis: Optimal driving signal distributions for hyperthermia
    • E. Ebbini and C. Cain, “Multiplc-focus ultrasound phased-array pattern synthesis: Optimal driving signal distributions for hyperthermia” IEEE Trans. Ullrason. Ferroelec. Freq. Contr., vol. 36, no. 5, pp. 540-548. 1989.
    • (1989) IEEE Trans. Ullrason. Ferroelec. Freq. Contr. , vol.36 , Issue.5 , pp. 540-548
    • Ebbini, E.1    Cain, C.2
  • 11
    • 0017512712 scopus 로고
    • A primary method for the determination of the ultrasonic intensity with elastic sphere radiometer
    • F. Dunn and W. D. O'Brien, “A primary method for the determination of the ultrasonic intensity with elastic sphere radiometer,” Acustica, vol. 38, pp. 58–61, 1977.
    • (1977) Acustica , vol.38 , pp. 58-61
    • Dunn, F.1    O'Brien, W.D.2
  • 12
    • 0024872677 scopus 로고
    • The pseudoinvcrsc pattern synthesis method: Experimental verification using a prototype cylindrical-section ultrasound hyperthermia phased-array applicator
    • E. Ebbini. F. Ngo, and C. Cain, “The pseudoinvcrsc pattern synthesis method: Experimental verification using a prototype cylindrical-section ultrasound hyperthermia phased-array applicator,” Proc. IEEE 1989 Ullrason. Symp., vol. 2, pp. 995-998.
    • (1989) Proc. IEEE 1989 Ullrason. Symp. , vol.2 , pp. 995-998
    • Ebbini, E.1    Ngo, F.2    Cain, C.3
  • 13
    • 0026220811 scopus 로고
    • Effect of phase quantization errors on field patterns generated by an ultrasound phased array hyperthermia applicator
    • H. Wang, E. Ebbini, and C. Cain, “Effect of phase quantization errors on field patterns generated by an ultrasound phased array hyperthermia applicator” IEEE Trans. Ullrason. Ferroelec. Freq. Contr., vol. 38, pp. 522-532, Sept. 1991.
    • (1991) IEEE Trans. Ullrason. Ferroelec. Freq. Contr. , vol.38 , pp. 522-532, Sept
    • Wang, H.1    Ebbini, E.2    Cain, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.