메뉴 건너뛰기




Volumn 38, Issue 2, 1991, Pages 780-783

Improved Lesion Detection in SPECT using MLEM Reconstruction

Author keywords

[No Author keywords available]

Indexed keywords

PHOTONS - EMISSION; PROBABILITY;

EID: 0026141024     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/23.289390     Document Type: Article
Times cited : (14)

References (14)
  • 1
    • 0002629270 scopus 로고
    • Maximum likelihood from incomplete data via the EM algorithm
    • Series B
    • A.P. Dempster, N.M. Laird and D.B. Rubin, “Maximum likelihood from incomplete data via the EM algorithm,” J. Royal Statist. Soc., Series B, vol.39, pp.1-38, 1977.
    • (1977) J. Royal Statist. Soc. , vol.39 , pp. 1-38
    • Dempster, A.P.1    Laird, N.M.2    Rubin, D.B.3
  • 2
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • K. Lange and R. Carson, “EM reconstruction algorithms for emission and transmission tomography”, J. Comput. Assist. Tomogr., vol. 8, pp. 306–316, 1984.
    • (1984) J. Comput. Assist. Tomogr. , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 3
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • L.A. Shepp and Y. Vardi, “Maximum likelihood reconstruction for emission tomography,” in IEEE Trans. Med. Imaging, vol. MI-1, pp.113-122 1982.
    • (1982) IEEE Trans. Med. Imaging , vol.MI-1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 4
    • 0023422273 scopus 로고
    • Noise and edge artifacts in maximum-likelihood reconstructions for emission tomography
    • D.L Snyder, M.I. Miller, L.J. Thomas and D.G. Politte, “Noise and edge artifacts in maximum-likelihood reconstructions for emission tomography,” in IEEE Trans. Med. Imaging, vol. 6, No.3, pp.228-238, 1987.
    • (1987) IEEE Trans. Med. Imaging , vol.6 , Issue.3 , pp. 228-238
    • Snyder, D.L.1    Miller, M.I.2    Thomas, L.J.3    Politte, D.G.4
  • 5
    • 0021373178 scopus 로고
    • Inverse Monte Carlo: a unified reconstruction algorithm for SPECT
    • C.E. Floyd, R.J. Jaszczak and R.E. Coleman, “Inverse Monte Carlo: a unified reconstruction algorithm for SPECT,” in IEEE Trans. Nuclear Science, vol. NS-32, No. 1, pp. 779–785, 1985.
    • (1985) IEEE Trans. Nuclear Science , vol.NS-32 , Issue.1 , pp. 779-785
    • Floyd, C.E.1    Jaszczak, R.J.2    Coleman, R.E.3
  • 6
    • 0344424815 scopus 로고
    • Analysis of a camera based single photon emission computed tomography (SPECT) system
    • Durham, NC, Ph.D. dissertation
    • J.W. Beck, “Analysis of a camera based single photon emission computed tomography (SPECT) system,” Duke University, Durham, NC, Ph.D. dissertation, 1982.
    • (1982) Duke University
    • Beck, J.W.1
  • 7
    • 0023100560 scopus 로고
    • Experimentally measured scatter fractions and energy spectra as a test of Monte Carlo simulations
    • S.H. Manglos, C.E. Floyd, R.J. Jaszczak, K.L. Greer, C.C. Harris and R.E. Coleman, “Experimentally measured scatter fractions and energy spectra as a test of Monte Carlo simulations,” Phys. Med. Biol., vol. 32, No. 3, pp. 335–343, 1987.
    • (1987) Phys. Med. Biol. , vol.32 , Issue.3 , pp. 335-343
    • Manglos, S.H.1    Floyd, C.E.2    Jaszczak, R.J.3    Greer, K.L.4    Harris, C.C.5    Coleman, R.E.6
  • 9
    • 0018390029 scopus 로고
    • ROC analysis applied to the evaluation of medical imaging techniques
    • J.A. Swets, “ROC analysis applied to the evaluation of medical imaging techniques,”, Investigative Radiology, vol. 14, No. 2, pp. 109–120, 1979.
    • (1979) Investigative Radiology , vol.14 , Issue.2 , pp. 109-120
    • Swets, J.A.1
  • 10
    • 0022470978 scopus 로고
    • ROC methodology in radiologic imaging
    • C.E. Metz, “ROC methodology in radiologic imaging,”, Investigative Radiology, vol. 21, pp. 720–733, 1986.
    • (1986) Investigative Radiology , vol.21 , pp. 720-733
    • Metz, C.E.1
  • 11
    • 0018983328 scopus 로고
    • Physical factors affecting quantitative measurements using camera-based Single Photon Emission Computed Tomography (SPECT)
    • R.J. Jaszczak, R.E. Coleman and F.R. Whitehead, “Physical factors affecting quantitative measurements using camera-based Single Photon Emission Computed Tomography (SPECT),” in IEEE Trans. Nuclear Science, vol. NS-28, No. 1, pp. 69–81, 1981.
    • (1981) IEEE Trans. Nuclear Science , vol.NS-28 , Issue.1 , pp. 69-81
    • Jaszczak, R.J.1    Coleman, R.E.2    Whitehead, F.R.3
  • 12
    • 0024511244 scopus 로고
    • Some practical issues of experimental design and data analysis in radiological ROC studies
    • C.E. Metz, “Some practical issues of experimental design and data analysis in radiological ROC studies,”, Investigative Radiology, vol. 24, pp. 234–245, 1989.
    • (1989) Investigative Radiology , vol.24 , pp. 234-245
    • Metz, C.E.1
  • 13
    • 0001745280 scopus 로고
    • Statistical significance tests for binormal ROC curves
    • C.E. Metz and H.B. Kronman, “Statistical significance tests for binormal ROC curves,”, J. Math. Psych., vol. 22, pp. 218–243, 1980.
    • (1980) J. Math. Psych. , vol.22 , pp. 218-243
    • Metz, C.E.1    Kronman, H.B.2
  • 14
    • 0002167042 scopus 로고
    • A new approach for testing the significance of differences between ROC curves measured from correlated data
    • The Hague: Nijhoff
    • C.E. Metz, Wang P-L and H.B. Kronman, “A new approach for testing the significance of differences between ROC curves measured from correlated data,”, in: Deconinck F., ed. Information processing in medical imaging, The Hague: Nijhoff, 1984, pp. 432–445.
    • (1984) Information processing in medical imaging , pp. 432-445
    • Metz, C.E.1    Wang, P.L.2    Kronman, H.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.