메뉴 건너뛰기




Volumn 38, Issue 2, 1991, Pages 693-702

Three-Dimensional Iterative Reconstruction Algorithms With Attenuation And Geometric Point Response Correction

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTERIZED TOMOGRAPHY; IMAGE PROCESSING - RECONSTRUCTION; MATHEMATICAL TECHNIQUES - ITERATIVE METHODS; PHOTONS - EMISSION;

EID: 0026139673     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/23.289376     Document Type: Article
Times cited : (202)

References (17)
  • 1
    • 0014353839 scopus 로고
    • Reorganizing data from transverse section scans of the brain using digital processing
    • D. E. Kuhl, R. Q. Edwards, “Reorganizing data from transverse section scans of the brain using digital processing,” Radiology, 1968, Vol. 91, p. 975-983.
    • (1968) Radiology , vol.91 , pp. 975-983
    • Kuhl, D.E.1    Edwards, R.Q.2
  • 2
    • 0017883692 scopus 로고
    • Radionuclide axial tomography by half back-projection
    • J. F. Isenberg, W. Simon, “Radionuclide axial tomography by half back-projection,” Phys. Med. Biol., 1978, Vol. 23, p. 154–158.
    • (1978) Phys. Med. Biol. , vol.23 , pp. 154-158
    • Isenberg, J.F.1    Simon, W.2
  • 3
    • 0022613168 scopus 로고
    • Distance-weighted backprojection: a SPECT reconstruction technique
    • D. J. Nowak, R. L. Eisner, W. A. Fajman, “Distance-weighted backprojection: a SPECT reconstruction technique,” Radiology, 1986, Vol. 159, p. 531-536.
    • (1986) Radiology , vol.159 , pp. 531-536
    • Nowak, D.J.1    Eisner, R.L.2    Fajman, W.A.3
  • 4
    • 0020624230 scopus 로고
    • Quantitative image reconstruction with weighted backprojection for single photon emission computed tomography
    • E. Tanaka, “Quantitative image reconstruction with weighted backprojection for single photon emission computed tomography,” J. Comput. Assist. Tomogr., 1983, Vol. 7, p. 692–700.
    • (1983) J. Comput. Assist. Tomogr. , vol.7 , pp. 692-700
    • Tanaka, E.1
  • 5
    • 0022577331 scopus 로고
    • Variation of the count-dependent Metz filter with imaging system modulation transfer function
    • M. A. King, R. B. Schwinger, B. C. Penney, “Variation of the count-dependent Metz filter with imaging system modulation transfer function,” Med. Phys., 1986, Vol. 13, p. 139–149.
    • (1986) Med. Phys. , vol.13 , pp. 139-149
    • King, M.A.1    Schwinger, R.B.2    Penney, B.C.3
  • 6
    • 0000946595 scopus 로고
    • Incorporation of detector response in projector and backprojector for SPECT image reconstruction
    • B. M. W. Tsui and R. J. Jaszczak, “Incorporation of detector response in projector and backprojector for SPECT image reconstruction,” J. Nucl. Med., 1987, Vol. 28, p. 566.
    • (1987) J. Nucl. Med. , vol.28 , pp. 566
    • Tsui, B.M.W.1    Jaszczak, R.J.2
  • 7
    • 84914803871 scopus 로고
    • A theoretic ally-correct algorithm to compensate for a three-dimensional spatially-variant point spread function in SPECT imaging
    • B. R. Zeeberg, S. Loncario, H. N. Wagner and R. C. Reba, “A theoretic ally-correct algorithm to compensate for a three-dimensional spatially-variant point spread function in SPECT imaging,”, J. Nucl. Med. 1987, Vol. 28, p. 662P
    • (1987) J. Nucl. Med. , vol.28 , pp. 662P
    • Zeeberg, B.R.1    Loncario, S.2    Wagner, H.N.3    Reba, R.C.4
  • 9
    • 0001579739 scopus 로고
    • Implementation of simultaneous attenuation and detector response correction in SPECT
    • B. M. W. Tsui, H. B. Hu, D. R. Gilland, and G. T. Gullberg, “Implementation of simultaneous attenuation and detector response correction in SPECT,” IEEE Trans, on Nucl. Sci., 1988, Vol. 35, pp. 778–783.
    • (1988) IEEE Trans, on Nucl. Sci. , vol.35 , pp. 778-783
    • Tsui, B.M.W.1    Hu, H.B.2    Gilland, D.R.3    Gullberg, G.T.4
  • 10
    • 0024569815 scopus 로고
    • Compensation of spatial system response in SPECT with conjugate gradient reconstruction technique
    • A. R. Formiconi, A. Pupi, and A. Passeri, “Compensation of spatial system response in SPECT with conjugate gradient reconstruction technique,” Phys. Med. Biol., 1989, Vol. 34, No. 1, pp. 69–84.
    • (1981) Phys. Med. Biol. , vol.34 , Issue.1 , pp. 69-84
    • Formiconi, A.R.1    Pupi, A.2    Passeri, A.3
  • 11
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • K. Lang and R. Carson, “EM reconstruction algorithms for emission and transmission tomography,” J. Comput. Assist. Tomogr., 1984, Vol. 8, pp. 306–316.
    • (1984) J. Comput. Assist. Tomogr. , vol.8 , pp. 306-316
    • Lang, K.1    Carson, R.2
  • 12
    • 0025442157 scopus 로고
    • Parameterization of scatter response function in SPECT imaging using Monte Carlo simulation
    • E. C. Frey and B. M. W. Tsui, “Parameterization of scatter response function in SPECT imaging using Monte Carlo simulation,” IEEE Trans. on Nucl. Sci., 1990, Vol. NS-37, pp. 1308–1315.
    • (1990) IEEE Trans. on Nucl. Sci. , vol.NS-37 , pp. 1308-1315
    • Frey, E.C.1    Tsui, B.M.W.2
  • 13
    • 0018414892 scopus 로고
    • A study of the point spread function in scintillation camera collimators based on Fourier analysis
    • S. Miracle, M. J. Yzuel, and S. Millan, “A study of the point spread function in scintillation camera collimators based on Fourier analysis,” Phys. Med. Biol., 1979, Vol. 24, pp. 372–384.
    • (1979) Phys. Med. Biol. , vol.24 , pp. 372-384
    • Miracle, S.1    Yzuel, M.J.2    Millan, S.3
  • 14
    • 0019136137 scopus 로고
    • The geometric transfer function component for scintillation camera collimators with straight parallel holes
    • C. E. Metz, F. B. Atkins and R. N. Beck, “The geometric transfer function component for scintillation camera collimators with straight parallel holes”, Phys. Med. Biol., 1980, Vol. 25, No. 6, pp. 1059–1070.
    • (1980) Phys. Med. Biol. , vol.25 , Issue.6 , pp. 1059-1070
    • Metz, C.E.1    Atkins, F.B.2    Beck, R.N.3
  • 15
    • 0025070160 scopus 로고
    • The geometric transfer function for cone and fan beam collimators
    • B. M. W. Tsui and G. T. Gullberg, “The geometric transfer function for cone and fan beam collimators,” Phys. Med. Biol., 1990, Vol. 35, No. 1, pp. 81–93.
    • (1990) Phys. Med. Biol. , vol.35 , Issue.1 , pp. 81-93
    • Tsui, B.M.W.1    Gullberg, G.T.2
  • 16
    • 0022415977 scopus 로고
    • An attenuated projector-backprojector for iterative SPECT reconstruction
    • G. T Gullberg, R. H. Huesman, J. A. Malko, N. J. Pelc, T. F. Budinger, “An attenuated projector-backprojector for iterative SPECT reconstruction,” Phy. Med. Biol., 1985, Vol. 30, pp. 799–816.
    • (1985) Phy. Med. Biol. , vol.30 , pp. 799-816
    • Gullberg, G.T.1    Huesman, R.H.2    Malko, J.A.3    Pelc, N.J.4    Budinger, T.F.5
  • 17
    • 84980278909 scopus 로고
    • An iterative reconstruction algorithm for single photon emission computed tomography with cone beam geometry
    • G. T. Gullberg, G. L. Zeng, B. M. W. Tsui, and J. T. Hagius, “An iterative reconstruction algorithm for single photon emission computed tomography with cone beam geometry,” Int. J. Imag. Sys. & Techn., 1989, Vol. 1, pp. 169–186.
    • (1989) Int. J. Imag. Sys. & Techn. , vol.1 , pp. 169-186
    • Gullberg, G.T.1    Zeng, G.L.2    Tsui, B.M.W.3    Hagius, J.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.