-
1
-
-
84918692332
-
A positron tomograph with 600 BGO crystals and 2.6 mm resolution
-
Derenzo S, Huesman R, Cahoon J, Geyer A, Moses W, Uber D, Vuletich T and Budinger T. A positron tomograph with 600 BGO crystals and 2.6 mm resolution: IEEE Trans. Nucl. Sci. NS-35(1), pp 659–664, 1988.
-
(1988)
IEEE Trans. Nucl. Sci.
, vol.NS-35
, Issue.1
, pp. 659-664
-
-
Derenzo, S.1
Huesman, R.2
Cahoon, J.3
Geyer, A.4
Moses, W.5
Uber, D.6
Vuletich, T.7
Budinger, T.8
-
2
-
-
0020088560
-
PET detector ring aperture function calculations using Monte Carlo techniques
-
Keller N and Lupton L. PET detector ring aperture function calculations using Monte Carlo techniques: IEEE Trans. Nucl. Sci. NS-30(1), pp 556–563, 1983.
-
(1983)
IEEE Trans. Nucl. Sci.
, vol.NS-30
, Issue.1
, pp. 556-563
-
-
Keller, N.1
Lupton, L.2
-
3
-
-
0021517269
-
On the use of tapered bismuth germanate crystals in positron emission tomography
-
Lupton L, Keller N, Thompson C and Anderson L. On the use of tapered bismuth germanate crystals in positron emission tomography: Nucl. Instr. Meth. Phys. Res. 227, pp 361–368, 1984.
-
(1984)
Nucl. Instr. Meth. Phys. Res.
, vol.227
, pp. 361-368
-
-
Lupton, L.1
Keller, N.2
Thompson, C.3
Anderson, L.4
-
4
-
-
0142063683
-
Designing a stratified detection system for PET
-
Wong H. Designing a stratified detection system for PET cameras: IEEE Trans. Nucl. Sci. NS-33(1), pp 591–596, 1986.
-
(1986)
cameras: IEEE Trans. Nucl. Sci.
, vol.NS-33
, Issue.1
, pp. 591-596
-
-
Wong, H.1
-
5
-
-
0001465864
-
Design of a high resolution positron emission tomograph using solid state scintillation detectors
-
Carrier C, Martel C, Schmitt D and Lecomte R. Design of a high resolution positron emission tomograph using solid state scintillation detectors: IEEE Trans. Nucl. Sci. NS-35(1), pp 685–690, 1998.
-
(1998)
IEEE Trans. Nucl. Sci.
, vol.NS-35
, Issue.1
, pp. 685-690
-
-
Carrier, C.1
Martel, C.2
Schmitt, D.3
Lecomte, R.4
-
6
-
-
0022028977
-
Effects of detector wobble motion on image noise in positron emission tomography
-
Palmer M, Bergstrom M, Beddoes M and Pate B. Effects of detector wobble motion on image noise in positron emission tomography: IEEE Trans. Med. Imaging MI-4(1), pp 58–62, 1985.
-
(1985)
IEEE Trans. Med. Imaging
, vol.MI-4
, Issue.1
, pp. 58-62
-
-
Palmer, M.1
Bergstrom, M.2
Beddoes, M.3
Pate, B.4
-
7
-
-
0023426484
-
Depth-of-interaction determination in NaI(Tl) and BGO scintillation crystals using a temperature gradient
-
Karp J and Daube-Witherspoon M. Depth-of-interaction determination in NaI(Tl) and BGO scintillation crystals using a temperature gradient: Nucl. Instrum. Meth. Phys. Res. A260, pp 509–517, 1987.
-
(1987)
Nucl. Instrum. Meth. Phys. Res.
, vol.A260
, pp. 509-517
-
-
Karp, J.1
Daube-Witherspoon, M.2
-
8
-
-
0024610741
-
Initial characterization of a position-sensitive photodiode/BGO detector for PET
-
Derenzo S, Moses W, Jackson H, Turko B, Cahoon J, Geyer A and Vuletich T. Initial characterization of a position-sensitive photodiode/BGO detector for PET: IEEE Trans. Nucl. Sci. NS-36(1), pp 1084–1089, 1989.
-
(1989)
IEEE Trans. Nucl. Sci.
, vol.NS-36
, Issue.1
, pp. 1084-1089
-
-
Derenzo, S.1
Moses, W.2
Jackson, H.3
Turko, B.4
Cahoon, J.5
Geyer, A.6
Vuletich, T.7
-
9
-
-
0020703469
-
Initial characterization of a BGO-photodiode detector for high resolution positron emission tomography
-
Derem S. Initial characterization of a BGO-photodiode detector for high resolution positron emission tomography: IEEE Trans. Nucl. Sci. NS-31(1), pp 620-626, 1984
-
(1984)
IEEE Trans. Nucl. Sci.
, vol.NS-31
, Issue.1
, pp. 620-626
-
-
Derem, S.1
-
10
-
-
0025414702
-
High resolution block detectors for PET
-
Yamashita Y, Watanabe M, Shimizu K and Uchida H. High resolution block detectors for PET: IEEE Trans. Nucl. Sci. NS-37(2), pp 589-593, 1990.
-
(1990)
IEEE Trans. Nucl. Sci.
, vol.NS-37
, Issue.2
, pp. 589-593
-
-
Yamashita, Y.1
Watanabe, M.2
Shimizu, K.3
Uchida, H.4
-
11
-
-
0024612466
-
A study of the possibility of using multislice PET systems for 3D imaging
-
Dahlbom M, Eriksson L, Rosenqvist D and Bohm C. A study of the possibility of using multislice PET systems for 3D imaging: IEEE Trans. Nucl. Sci. NS-36(2), pp 1066-1071, 1989.
-
(1989)
IEEE Trans. Nucl. Sci.
, vol.NS-36
, Issue.2
, pp. 1066-1071
-
-
Dahlbom, M.1
Eriksson, L.2
Rosenqvist, D.3
Bohm, C.4
-
12
-
-
0025419324
-
The effects of detector material and structure on PET resolution and efficincy
-
Thompson C.J: The effects of detector material and structure on PET resolution and efficincy. IEEE Trans. Nucl. Sci. NS-37, pp 718-724, 1990
-
(1990)
IEEE Trans. Nucl. Sci.
, vol.NS-37
, pp. 718-724
-
-
Thompson, C.J.1
-
13
-
-
84939007238
-
Development of 3-D detector system for positron CT
-
Shimizu K, Ohmura T, Watanabe M, Uchida H and Yamashita T. Development of 3-D detector system for positron CT: IEEE Trans. Nucl. Sci. NS35(1), pp 717-720, 1988.
-
(1988)
IEEE Trans. Nucl. Sci.
, vol.NS-35
, Issue.1
, pp. 717-720
-
-
Shimizu, K.1
Ohmura, T.2
Watanabe, M.3
Uchida, H.4
Yamashita, T.5
-
14
-
-
84939701887
-
Performance evaluation of the PC2048, a new 15-slice encoded-crystal PET scanner for neurological studies
-
Evans A, Thompson C, Marrett S and Meyer E. Performance evaluation of the PC2048, a new 15-slice encoded-crystal PET scanner for neurological studies: Submitted to IEEE Trans. Med. Imag.
-
IEEE Trans. Med. Imag.
-
-
Evans, A.1
Thompson, C.2
Marrett, S.3
Meyer, E.4
-
16
-
-
0020090090
-
A dual processing system for PET data handling
-
Thompson C.J., A dual processing system for PET data handling: IEEE Trans. Nucl. Sci. NS-30(1), pp 257-262, 1983.
-
(1983)
IEEE Trans. Nucl. Sci.
, vol.NS-30
, Issue.1
, pp. 257-262
-
-
Thompson, C.J.1
|