Performance Evaluation of the PC-2048: A New 15-Slice Encoded-Crystal PET Scanner for Neurological Studies

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER WORKSTATIONS; COMPUTERIZED TOMOGRAPHY - EQUIPMENT; IMAGE PROCESSING - RECONSTRUCTION; NOISE, SPURIOUS SIGNAL; PHOTODETECTORS;

EID: 0026121711     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/42.75615     Document Type: Article
Times cited : (87)

References (19)
  • 1
    • 84941543251 scopus 로고
    • Performance characteristics of a high-resolution PET scanner for brain imaging in three dimensions
    • St. Louis, MO
    • A. C. Evans, C. J. Thompson, S. Marrett, R. Weltman, and S. Holte, “Performance characteristics of a high-resolution PET scanner for brain imaging in three dimensions,’’ presented at Soc. Nucl. Med. Symp., St. Louis, MO, 1989.
    • (1989) presented at Soc. Nucl. Med. Symp.
    • Evans, A.C.1    Thompson, C.J.2    Marrett, S.3    Weltman, R.4    Holte, S.5
  • 2
    • 0005878501 scopus 로고
    • A preliminary evaluation of a positron camera system using weighted decoding of individual crystals
    • S. Holte et al., “A preliminary evaluation of a positron camera system using weighted decoding of individual crystals,” IEEE Trans. Nucl. Sci., vol. 35, pp. 730-734, 1988.
    • (1988) IEEE Trans. Nucl. Sci. , vol.35 , pp. 730-734
    • Holte, S.1
  • 3
    • 0020703945 scopus 로고    scopus 로고
    • Performance figures and images from the Theras-can 3128 positron emission tomograph
    • B. E. Cooke, A. C. Evans, E. O. Fanthome, R. Alarie, and A. M. Sendyk, “Performance figures and images from the Theras-can 3128 positron emission tomograph,” IEEE Trans. Nucl. Sci., vol. 31, pp. 640-644.
    • IEEE Trans. Nucl. Sci. , vol.31 , pp. 640-644
    • Cooke, B.E.1    Evans, A.C.2    Fanthome, E.O.3    Alarie, R.4    Sendyk, A.M.5
  • 4
    • 0012922027 scopus 로고
    • The orbiting rod source: Improving performance in PET transmission correction scans
    • New York, Publishers: The Society of Nuclear Medicine
    • L. R. Carroll, P. Kertz, and G. Orcut, “The orbiting rod source: Improving performance in PET transmission correction scans,” in Emission Computed Tomography; Current Trends. New York, Publishers: The Society of Nuclear Medicine, 1983.
    • (1983) Emission Computed Tomography; Current Trends
    • Carroll, L.R.1    Kertz, P.2    Orcut, G.3
  • 5
    • 0001465866 scopus 로고
    • Orbiting transmission source for positron tomography
    • R. H. Huesman et al., “Orbiting transmission source for positron tomography,” IEEE Trans. Nucl. Sci., vol. 35, pp. 735-739, 1988.
    • (1988) IEEE Trans. Nucl. Sci. , vol.35 , pp. 735-739
    • Huesman, R.H.1
  • 6
    • 0024328334 scopus 로고
    • The application of a masked orbiting transmission source for attenuation correction in PET
    • N. T. Ranger, C. J. Thompson, and A. C. Evans, “The application of a masked orbiting transmission source for attenuation correction in PET,” J. Nucl. Med., vol. 30, pp. 1056-1068, 1989.
    • (1989) J. Nucl. Med. , vol.30 , pp. 1056-1068
    • Ranger, N.T.1    Thompson, C.J.2    Evans, A.C.3
  • 8
    • 0022862637 scopus 로고
    • Imaging performance of a dynamic positron emission tomograph: Positome IIIp
    • C. J. Thompson, A. Dagher, E. Meyer, and A. C. Evans, “Imaging performance of a dynamic positron emission tomograph: Positome IIIp,” IEEE Trans. Med. Imag., vol. 5, no. 4, pp. 183-198, 1986.
    • (1986) IEEE Trans. Med. Imag. , vol.5 , Issue.4 , pp. 183-198
    • Thompson, C.J.1    Dagher, A.2    Meyer, E.3    Evans, A.C.4
  • 9
    • 0024612465 scopus 로고
    • Simultaneous transmission and emission scans in positron emission tomography
    • C. J. Thompson, N. T. Ranger, and A. C. Evans, “Simultaneous transmission and emission scans in positron emission tomography,” IEEE Trans. Nucl. Sci., vol. 36, pp. 1011-1016, 1989.
    • (1989) IEEE Trans. Nucl. Sci. , vol.36 , pp. 1011-1016
    • Thompson, C.J.1    Ranger, N.T.2    Evans, A.C.3
  • 11
    • 0020660172 scopus 로고
    • Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections
    • M. Bergstrom, L. Eriksson, C. Bohm, G. Blomqvist, and J. Litton, “Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections,” J. Comput. Assist. Tomogr., vol. 7, pp. 42-50, 1983.
    • (1983) J. Comput. Assist. Tomogr. , vol.7 , pp. 42-50
    • Bergstrom, M.1    Eriksson, L.2    Bohm, C.3    Blomqvist, G.4    Litton, J.5
  • 14
    • 0020606181 scopus 로고
    • A phantom to assess quantitative recovery in positron tomograph
    • B. E. Cooke and A. C. Evans, “A phantom to assess quantitative recovery in positron tomograph,” J. Comput. Assist. Tomogr., pp. 876-880, 1983.
    • (1983) J. Comput. Assist. Tomogr. , pp. 876-880
    • Cooke, B.E.1    Evans, A.C.2
  • 15
    • 0021030757 scopus 로고
    • Brain blood flow measured with intravenous H2 15O I. Theory and error analysis
    • P. Herscovitch, J. Markham, and M. E. Raichle, “Brain blood flow measured with intravenous H2 15O I. Theory and error analysis,” J. Nucl. Med., vol. 24, pp. 782-789, 1983.
    • (1983) J. Nucl. Med. , vol.24 , pp. 782-789
    • Herscovitch, P.1    Markham, J.2    Raichle, M.E.3
  • 16
    • 0021084822 scopus 로고
    • Brain blood flow measured with intravenous H2 15O II. Implementation and validation
    • M. E. Raichle, W. R. W. Martin, P. Herscovitch, M. A. Mintun, and J. Markham, “Brain blood flow measured with intravenous H2 15O II. Implementation and validation,” J. Nucl. Med., vol. 24, pp. 790-798, 1983.
    • (1983) J. Nucl. Med. , vol.24 , pp. 790-798
    • Raichle, M.E.1    Martin, W.R.W.2    Herscovitch, P.3    Mintun, M.A.4    Markham, J.5
  • 18
    • 0018582265 scopus 로고
    • Tomographic measurement of local cerebral glucose metabolic rate in humans with (F-18) 2-fluoro-2-deoxy-D-glucose: Validation of method
    • M. E. Phelps, S.-C. Huang, E. J. Hoffman, C. Selin, L. Sokoloff, and D. E. Kuhl, “Tomographic measurement of local cerebral glucose metabolic rate in humans with (F-18) 2-fluoro-2-deoxy-D-glucose: Validation of method,” Ann. Neurol., vol. 6, pp. 371-388, 1979.
    • (1979) Ann. Neurol. , vol.6 , pp. 371-388
    • Phelps, M.E.1    Huang, S.-C.2    Hoffman, E.J.3    Selin, C.4    Sokoloff, L.5    Kuhl, D.E.6
  • 19
    • 0024143307 scopus 로고
    • An evaluation of a two-dimensional array detector for high resolution PET
    • M. Dahlbom and E. J. Hoffman, “An evaluation of a two-dimensional array detector for high resolution PET,” IEEE Trans. Med. Imag., vol. MI-7, pp. 264-272, 1988.
    • (1988) IEEE Trans. Med. Imag. , vol.MI-7 , pp. 264-272
    • Dahlbom, M.1    Hoffman, E.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.