메뉴 건너뛰기




Volumn 38, Issue 1, 1991, Pages 68-74

Multisite Microprobes for Neural Recordings

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL EQUIPMENT--MICROELECTRODES; BIOSENSORS; INTEGRATED CIRCUITS--APPLICATIONS; PROBES;

EID: 0026024523     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/10.68211     Document Type: Article
Times cited : (75)

References (12)
  • 1
    • 11144238951 scopus 로고
    • Activation of single neurons in the tactile thalamic region of the cat in response to a transient peripheral stimulus
    • J. E. Rose and V. B. Mountcastle, “Activation of single neurons in the tactile thalamic region of the cat in response to a transient peripheral stimulus,” Bull. The Johns Hopkins Hospital, vol. 94, pp. 238–282, 1954.
    • (1954) Bull. The Johns Hopkins Hospital , vol.94 , pp. 238-282
    • Rose, J.E.1    Mountcastle, V.B.2
  • 2
    • 0019505585 scopus 로고
    • Simultaneous recording of 30 microelectrodes in monkey visual cortex
    • J. Kruger and M. Bach, “Simultaneous recording of 30 microelectrodes in monkey visual cortex,” Exp. Brain Res., vol. 41, pp. 191–194, 1981.
    • (1981) Exp. Brain Res. , vol.41 , pp. 191-194
    • Kruger, J.1    Bach, M.2
  • 3
    • 0020656569 scopus 로고
    • Multielectrode recording system for the study of spatio-temporal activity patterns of neurons in the central nervous system
    • H. J. Reitbock and G. Werner, “Multielectrode recording system for the study of spatio-temporal activity patterns of neurons in the central nervous system,” Experientia, vol. 39, p. 339, 1983.
    • (1983) Experientia , vol.39 , pp. 339
    • Reitbock, H.J.1    Werner, G.2
  • 4
    • 0022559398 scopus 로고
    • Thin-film multiple electrode probes; Possibilities and limitations
    • O. J. Prohaska et al., “Thin-film multiple electrode probes; Possibilities and limitations,” IEEE Trans. Blamed. Eng., vol. BME-33, pp. 223–229, 1986.
    • (1986) IEEE Trans. Blamed. Eng. , vol.BME-33 , pp. 223-229
    • Prohaska, O.J.1
  • 5
    • 0024076268 scopus 로고
    • Performance of planar multisite microprobes in recording extracellular single-unit intracortical activity
    • Sept.
    • K. L. Drake, K. D. Wise, J. Farraye, D. J. Anderson and S. L. BeMent, “Performance of planar multisite microprobes in recording extracellular single-unit intracortical activity,” IEEE Trans. Biomed. Eng., vol. 35, pp. 719–732, Sept. 1988.
    • (1988) IEEE Trans. Biomed. Eng. , vol.35 , pp. 719-732
    • Drake, K.L.1    Wise, K.D.2    Farraye, J.3    Anderson, D.J.4    BeMent, S.L.5
  • 6
    • 0022448771 scopus 로고
    • Extracellular neural recording with multichannel microelectrodes
    • H. Eichenbaum and M. Kuperstein, “Extracellular neural recording with multichannel microelectrodes,” J. Electrophysiol. Tech., vol. 13, pp. 189–209, 1986.
    • (1986) J. Electrophysiol. Tech. , vol.13 , pp. 189-209
    • Eichenbaum, H.1    Kuperstein, M.2
  • 7
    • 0021657426 scopus 로고
    • Polyimides as insulating layers for implantable electrodes
    • K. L. Mittal, Ed. New York: Plenum
    • H. K. Charles, Jr., J. T. Massey, and V. B. Mountcastle, “Polyimides as insulating layers for implantable electrodes,” in Polyimides, Vol. 2, K. L. Mittal, Ed. New York: Plenum, 1984, pp. 1139–1159.
    • (1984) Polyimides , vol.2 , pp. 1139-1159
    • Charles, H.K.1    Massey, J.T.2    Mountcastle, V.B.3
  • 8
    • 0016125157 scopus 로고
    • An evaluation of the resistance to electrolysis of metals for use in biostimulation microprobes
    • R. L. White and T. J. Gross, “An evaluation of the resistance to electrolysis of metals for use in biostimulation microprobes,” IEEE Trans. Biomed. Eng., vol. BME-21, pp. 487–490, 1974.
    • (1974) IEEE Trans. Biomed. Eng. , vol.BME-21 , pp. 487-490
    • White, R.L.1    Gross, T.J.2
  • 9
    • 0018163887 scopus 로고
    • Histopathological evaluation of materials implanted in the cerebral cortex
    • S. S. Stensaas and L. J. Stensaas, “Histopathological evaluation of materials implanted in the cerebral cortex,” Acta Neuropathologica, vol. 41, pp. 145–155, 1978.
    • (1978) Acta Neuropathologica , vol.41 , pp. 145-155
    • Stensaas, S.S.1    Stensaas, L.J.2
  • 10
    • 5844400776 scopus 로고
    • A planar multisite microprobe for recording simultaneous single-unit cortical activity
    • Tech. Rep. 179, Solid State Electron. Lab., Dep. Elect. Eng. Comput. Sci., Univ. Michigan, Ann Arbor, MI, Oct.
    • K. L. Drake, “A planar multisite microprobe for recording simultaneous single-unit cortical activity,” Tech. Rep. 179, Solid State Electron. Lab., Dep. Elect. Eng. Comput. Sci., Univ. Michigan, Ann Arbor, MI, Oct. 1987, p. 27.
    • (1987) , pp. 27
    • Drake, K.L.1
  • 11
    • 84914549190 scopus 로고
    • Involvement of nucleus raphe magnus in the supraspinal control of splanchnic input to the thoracic spinal cord of rat
    • E. W. Akeyson, M. M. Kneupfer, and L. P. Schramm, “Involvement of nucleus raphe magnus in the supraspinal control of splanchnic input to the thoracic spinal cord of rat,” Soc. Neurosci. Abst., vol. 12, p. 1057, 1986.
    • (1986) Soc. Neurosci. Abst. , vol.12 , pp. 1057
    • Akeyson, E.W.1    Kneupfer, M.M.2    Schramm, L.P.3
  • 12
    • 0024125097 scopus 로고
    • Multi-microelectrode probe for neurophysiological experiments
    • Proc. 14th Northeast Bioeng. Conf., J. R. LaCourse, Ed., IEEE Pub. No. 88-CHZ666-6
    • N. A. Blum and H. K. Charles, Jr., “Multi-microelectrode probe for neurophysiological experiments,” in Proc. 14th Northeast Bioeng. Conf., J. R. LaCourse, Ed., IEEE Pub. No. 88-CHZ666-6, 1988.
    • (1988)
    • Blum, N.A.1    Charles, H.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.