2
-
-
0021442827
-
Acoustic emission: Its techniques and applications
-
pt. A
-
R. Dukes and E.A. Culpan, ’’Acoustic emission: Its techniques and applications”, IEEE Proc., vol. 131, pt. A, pp. 241-251, 1984.
-
(1984)
IEEE Proc.
, vol.131
, pp. 241-251
-
-
Dukes, R.1
Culpan, E.A.2
-
3
-
-
23544439171
-
Acoustical techniques for detecting and locating electrical discharges
-
Corona Measurement and Interpretation, Philadelphia: ASTM, In R. Bartnikas and E.J. McMahon, (eds.)
-
R.T. Harrold, ’’Acoustical techniques for detecting and locating electrical discharges” in R. Bartnikas and E.J. McMahon, (eds.), Engineering Dielectrics vol. 1: Corona Measurement and Interpretation, Philadelphia: ASTM, 1979.
-
(1979)
Engineering Dielectrics
, vol.1
-
-
Harrold, R.T.1
-
4
-
-
0015996179
-
Testing of gas insulated substations and transmission systems
-
H.Q. Graybill, J.C. Cronon and E.J. Field, “Testing of gas insulated substations and transmission systems”, IEEE Trans. Power App. Syst., vol. PAS-93, pp. 404-413, 1974.
-
(1974)
IEEE Trans. Power App. Syst.
, vol.PAS-93
, pp. 404-413
-
-
Graybill, H.Q.1
Cronon, J.C.2
Field, E.J.3
-
5
-
-
0019044046
-
Diagnostic technique of gas insulated substation by partial discharge detection
-
S. Kosumoto, S. Itoh, Y. Tsuchiya, H. Mukae, S. Matsuda and K. Takahashi, “Diagnostic technique of gas insulated substation by partial discharge detection”, IEEE Trans. Power App. Syst., vol. PAS-99, pp. 1456-1465, 1980.
-
(1980)
IEEE Trans. Power App. Syst.
, vol.PAS-99
, pp. 1456-1465
-
-
Kosumoto, S.1
Itoh, S.2
Tsuchiya, Y.3
Mukae, H.4
Matsuda, S.5
Takahashi, K.6
-
6
-
-
0019575124
-
Pattern recognition of vibrations in metal enclosures of gas insulated equipment and its application
-
N. Okutsu, S. Matsuda, H. Mukae, T. Takahashia and S. Tominaga, “Pattern recognition of vibrations in metal enclosures of gas insulated equipment and its application”, IEEE Trans. Power App. Syst., vol. PAS-100, pp. 2733-2739, 1981.
-
(1981)
IEEE Trans. Power App. Syst.
, vol.PAS-100
, pp. 2733-2739
-
-
Okutsu, N.1
Matsuda, S.2
Mukae, H.3
Takahashia, T.4
Tominaga, S.5
-
7
-
-
84941540877
-
Experiences and considerations regarding erection testing and operation availability of GIS in Sweden
-
paper no. 23-07
-
B. Wahlstr ö m, W. Lord, K. Petterson, R. Alvinson and M.A.S. Leijon, “Experiences and considerations regarding erection testing and operation availability of GIS in Sweden”, CIGRE, Paris, 1988, paper no. 23-07.
-
(1988)
CIGRE, Paris
-
-
Wahlström, B.1
Lord, W.2
Petterson, K.3
Alvinson, R.4
Leijon, M.A.S.5
-
8
-
-
0023015732
-
Onsite acoustic detection of abnormalities in metal-clad substations
-
J. Lalot, “Onsite acoustic detection of abnormalities in metal-clad substations”, in Proc. Int. Symp. Gas Insulated Substations, Toronto, 1985, PP. 322-330.
-
(1985)
Proc. Int. Symp. Gas Insulated Substations, Toronto
, pp. 322-330
-
-
Lalot, J.1
-
9
-
-
0023027258
-
On-site particle detection in GIS by acoustic measurement
-
P.H. Spaeren, B. Skyberg, R. Hegerberg and L.E. Lundgaard, “On-site particle detection in GIS by acoustic measurement”, in Proc. Int. Symp. Gas Insulated Substations, Toronto, 1985, PP. 331- 340.
-
(1985)
Proc. Int. Symp. Gas Insulated Substations, Toronto
, pp. 331-340
-
-
Spaeren, P.H.1
Skyberg, B.2
Hegerberg, R.3
Lundgaard, L.E.4
-
10
-
-
0023670143
-
Development of compact 500 kV 8000 A gas insulated transmissionline - dirt control during field jointing and method for detecting conductive particles
-
K. Kaminaga, M. Koshiishi, T. Hayashi, M. Matsuki, T. Hara and N. Sugiyama, “Development of compact 500 kV 8000 A gas insulated transmission line - dirt control during field jointing and method for detecting conductive particles”, IEEE Trans. Power Del., vol. PWRD-2, pp. 961-968, 1987.
-
(1987)
IEEE Trans. Power Del
, vol.PWRD-2
, pp. 961-968
-
-
Kaminaga, K.1
Koshiishi, M.2
Hayashi, T.3
Matsuki, M.4
Hara, T.5
Sugiyama, N.6
-
11
-
-
0342338400
-
Partial discharge and particle detection in GIS using acoustic emission technique
-
paper no. 12.08
-
L.E. Lundgaard, R. Hegerberg and B. Skyberg, “Partial discharge and particle detection in GIS using acoustic emission technique”, in Proc. 5th Int. Symp. High Voltage Eng., Braunschweig, 1987, paper no. 12.08.
-
(1987)
Proc. 5th Int. Symp. High Voltage Eng., Braunschweig
-
-
Lundgaard, L.E.1
Hegerberg, R.2
Skyberg, B.3
-
13
-
-
84941540881
-
On-site acoustic detection of defects in GIS: Improvement of the commissioning tests
-
paper no. 32.12
-
G. Riquel, “On-site acoustic detection of defects in GIS: Improvement of the commissioning tests”, in Proc. 6th Int. Symp. High Voltage Eng., New Orleans, 1989, paper no. 32.12.
-
(1989)
Proc. 6th Int. Symp. High Voltage Eng., New Orleans
-
-
Riquel, G.1
-
14
-
-
84941540882
-
Acoustic detection, localization and identification of anomalities in GIS
-
paper no. 23.07
-
B.H.E. Wahlstr ö m, W.S.G. Lord, P.E. Hoff, P. O. Karrvall and M.A.S. Leijon, “Acoustic detection, localization and identification of anomalities in GIS”, in Proc. 6th Int. Symp. High Voltage Eng., New Orleans, 1989, paper no. 23.07.
-
(1989)
Proc. 6th Int. Symp. High Voltage Eng., New Orleans
-
-
Wahlström, B.H.E.1
Lord, W.S.G.2
Hoff, P.E.3
Karrvall, P.O.4
Leijon, M.A.S.5
-
17
-
-
12544260238
-
Location of discharges in power transformers using external acoustic sensors
-
paper no. 15.05
-
L.E. Lundgaard, W. Hansen and K. Dursun, “Location of discharges in power transformers using external acoustic sensors”, in Proc. 6th Int. Symp. High Voltage Eng., New Orleans, 1989, paper no. 15.05.
-
(1989)
Proc. 6th Int. Symp. High Voltage Eng., New Orleans
-
-
Lundgaard, L.E.1
Hansen, W.2
Dursun, K.3
-
18
-
-
84941540884
-
Detection of partial discharges and free particles in gas insulated equipment by acoustic emission technique
-
paper no. 20
-
R. Hegerberg, L.E. Lundgaard and G. Øvstun, “Detection of partial discharges and free particles in gas insulated equipment by acoustic emission technique”, in Proc. Nordic Symp. Insulation, Odense, 1982, paper no. 20.
-
(1982)
Proc. Nordic Symp. Insulation, Odense
-
-
Hegerberg, R.1
Lundgaard, L.E.2
Øvstun, G.3
-
19
-
-
0007931614
-
Movement of filamentary conducting particles under AC voltages in high pressure gas
-
A. H. Cookson and R. E. Wootton, “Movement of filamentary conducting particles under AC voltages in high pressure gas”, in Proc. Int. Symp. High Voltage Eng., Zurich, 1975. PP. 416-420.
-
(1975)
Proc. Int. Symp. High Voltage Eng., Zurich
, pp. 416-420
-
-
Cookson, A.H.1
Wootton, R.E.2
-
20
-
-
84941529025
-
Influence of Conducting Particles on the SF6 Gas Gap Breakdown and Spacer Flashover in GIS, Doctoral Thesis
-
L. Ming, Influence of Conducting Particles on the SF6 Gas Gap Breakdown and Spacer Flashover in GIS, Doctoral Thesis, Chalmers Univ. of Technol., GSteborg, 1987.
-
(1987)
Chalmers Univ. of Technol., GSteborg
-
-
Ming, L.1
-
21
-
-
84915292336
-
A knowledge based diagnostic system for gas insulated substations
-
G. Tangen, “A knowledge based diagnostic system for gas insulated substations”, in Proc. 2nd Symp. Expert Syst. Power Syst., Seattle, 1989, pp. 200-205.
-
(1989)
Proc. 2nd Symp. Expert Syst. Power Syst., Seattle
, pp. 200-205
-
-
Tangen, G.1
-
23
-
-
84945724935
-
Study of diagnostic methods for the identification of defects inside GIS
-
O. Celi, W. Koltunowicz, A. Pigini, B.S. Manjunath, M.C. Ratra, G. Basile, S. Girolomoni “ Study of diagnostic methods for the identification of defects inside GIS” ISH New Orleans 1989.
-
(1989)
ISH New Orleans
-
-
Celi, O.1
Koltunowicz, W.2
Pigini, A.3
Manjunath, B.S.4
Ratra, M.C.5
Basile, G.6
Girolomoni, S.7
|