메뉴 건너뛰기




Volumn 37, Issue 2, 1990, Pages 664-670

Detector, shielding and geometric design factors for a high-resolution PET system

Author keywords

[No Author keywords available]

Indexed keywords

BISMUTH COMPOUNDS; MATHEMATICAL STATISTICS--MONTE CARLO METHODS; SCINTILLATION COUNTERS;

EID: 0025418432     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/23.106695     Document Type: Article
Times cited : (27)

References (8)
  • 1
    • 0020091155 scopus 로고
    • A quad BGO detector and its timing and positioning discrimination for positron computed tomography
    • H. Murayama, N. Nohara and E. Tanaka, “A quad BGO detector and its timing and positioning discrimination for positron computed tomography,” Nucl. Instr. Meth., vol. 192, pp 501–511, 1982.
    • (1982) Nucl. Instr. Meth. , vol.192 , pp. 501-511
    • Murayama, H.1    Nohara, N.2    Tanaka, E.3
  • 2
    • 84939045331 scopus 로고
    • A multislice two dimensional BGO detector system for PET
    • M.E. Casey and R. Nutt, “A multislice two dimensional BGO detector system for PET,” IEEE Trans. Nucl. Sci., vol. NS-33, pp 460–463, 1986.
    • (1986) IEEE Trans. Nucl. Sci. , vol.NS-33 , pp. 460-463
    • Casey, M.E.1    Nutt, R.2
  • 4
    • 0024143307 scopus 로고
    • An evaluation of a two-dimensional dimensional array detector for high resolution PET
    • M. Dahlbom and E.J. Hoffman, “An evaluation of a two-dimensional dimensional array detector for high resolution PET,” IEEE Trans. Med Imaging, vol. 7, no. 4, pp 264–272, 1988.
    • (1988) IEEE Trans. Med Imaging , vol.7 , Issue.4 , pp. 264-272
    • Dahlbom, M.1    Hoffman, E.J.2
  • 5
    • 8944247925 scopus 로고
    • A new PET system for high-resolution 3-dimensional dimensional brain imaging
    • E. Hoffman, M. Phelps, S. Huang, J. Mazziotta, W. Digby and M. Dahlbom, “A new PET system for high-resolution 3-dimensional dimensional brain imaging,” J. Nucl. Med., vol. 28, no. 4, pp 758–759, 1987.
    • (1987) J. Nucl. Med. , vol.28 , Issue.4 , pp. 758-759
    • Hoffman, E.1    Phelps, M.2    Huang, S.3    Mazziotta, J.4    Digby, W.5    Dahlbom, M.6
  • 8
    • 0024612466 scopus 로고
    • A study of the possibility of using multi-slice PET systems for 3D imaging
    • M. Dahlbom, L. Eriksson, G. Rosenqvist and C. Bohm, “A study of the possibility of using multi-slice PET systems for 3D imaging,” IEEE Trans. Nucl. Sci., vol NS-36, pp 1066–1071, 1989.
    • (1989) IEEE Trans. Nucl. Sci. , vol.NS-36 , pp. 1066-1071
    • Dahlbom, M.1    Eriksson, L.2    Rosenqvist, G.3    Bohm, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.