메뉴 건너뛰기




Volumn 37, Issue 2, 1990, Pages 754-758

Fast Methods for Including Attenuation in the EM Algorithm

Author keywords

[No Author keywords available]

Indexed keywords

MATHEMATICAL TECHNIQUES--ALGORITHMS; PHOTONS--EMISSION; PROBABILITY;

EID: 0025414329     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/23.106710     Document Type: Article
Times cited : (46)

References (14)
  • 2
    • 0018480166 scopus 로고
    • Compensation of Tissue Absorption in Emission Tomography
    • June
    • S. Bellini, M. Piacentini, C. Cafforio, F. Rocca; “Compensation of Tissue Absorption in Emission Tomography;” IEEE Trans ASSP, Vol 27, No. 3, pp 213–218, June 1979.
    • (1979) IEEE Trans ASSP , vol.27 , Issue.3 , pp. 213-218
    • Bellini, S.1    Piacentini, M.2    Cafforio, C.3    Rocca, F.4
  • 3
    • 0018457482 scopus 로고
    • Attenuation Correction and Incomplete Projection in SPECT
    • April
    • L. Chang; “Attenuation Correction and Incomplete Projection in SPECT;” IEEE Trans Nuc Sci; Vol 26, April 1979.
    • (1979) IEEE Trans Nuc Sci , vol.26
    • Chang, L.1
  • 4
    • 0002629270 scopus 로고
    • Maximum Likelihood from Incomplete Data via the EM Algorithm
    • series B
    • A.P. Dempster, N. Laird, D. Rubin; “Maximum Likelihood from Incomplete Data via the EM Algorithm;” J. Royal Statistical Soc; series B, Vol 39, 1977.
    • (1977) J. Royal Statistical Soc , vol.39
    • Dempster, A.P.1    Laird, N.2    Rubin, D.3
  • 5
    • 0024611797 scopus 로고
    • An Investigation of the Stationarity of the 3-D Modulation Transfer Function of SPECT
    • Feb.
    • S. J. Glick, M. King, K. Knesaurek, K. Burbank; “An Investigation of the Stationarity of the 3-D Modulation Transfer Function of SPECT;” IEEE Trans Nuc Sci, Vol NS-36, pp 973–977, Feb. 1989.
    • (1989) IEEE Trans Nuc Sci , vol.NS-36 , pp. 973-977
    • Glick, S.J.1    King, M.2    Knesaurek, K.3    Burbank, K.4
  • 6
    • 0022415977 scopus 로고
    • An Attenuated Projector-Backprojector for iterative SPECT
    • G. Gullberg, R. Huesman, J. Malko, N. Pele, T. Budinger; “An Attenuated Projector-Backprojector for iterative SPECT;” Phys Med Biol, Vol 30, pp 799–816, 1985.
    • (1985) Phys Med Biol , vol.30 , pp. 799-816
    • Gullberg, G.1    Huesman, R.2    Malko, J.3    Pele, N.4    Budinger, T.5
  • 7
    • 45049085300 scopus 로고
    • Fast MLE for SPECT using an Intermediate Polar Representation and a Stopping Criterion
    • Feb.
    • T. Hebert, R. Leahy, M. Singh; “Fast MLE for SPECT using an Intermediate Polar Representation and a Stopping Criterion,” IEEE Trans Nuc Sci, Vol NS-35, pp 615–619, Feb. 1988.
    • (1988) IEEE Trans Nuc Sci , vol.NS-35 , pp. 615-619
    • Hebert, T.1    Leahy, R.2    Singh, M.3
  • 8
    • 0024681039 scopus 로고
    • A Generalized EM Algorithm for 3-D D Bayesian Reconstruction from Poisson Data using Gibbs Priors
    • June
    • T. Hebert, R. Leahy; “A Generalized EM Algorithm for 3-D D Bayesian Reconstruction from Poisson Data using Gibbs Priors;” IEEE Trans Med Imag, Vol 8, No. 2, pp 194–202, June 1989.
    • (1989) IEEE Trans Med Imag , vol.8 , Issue.2 , pp. 194-202
    • Hebert, T.1    Leahy, R.2
  • 9
    • 0343729971 scopus 로고
    • First Order Correction for Absorption and Resolution Compensation in Radionuclide Fourier Tomography
    • IEEE Trans. Med. Imaging; June 1989
    • D. B. Kay, J. W. Keyes; “First Order Correction for Absorption and Resolution Compensation in Radionuclide Fourier Tomography;” J Nucl Med Vol 16, pp 540, 1975. IEEE Trans. Med. Imaging; June 1989.
    • (1975) J Nucl Med , vol.16 , pp. 540
    • Kay, D.B.1    Keyes, J.W.2
  • 10
    • 0023314408 scopus 로고
    • Implementing and Accelerating the EM Algorithm for PET
    • L. Kaufman; “Implementing and Accelerating the EM Algorithm for PET;” IEEE Trans Med Imag, MI-6,1,37–51, 1987.
    • (1987) IEEE Trans Med Imag , vol.MI-6 , Issue.1 , pp. 37-51
    • Kaufman, L.1
  • 11
    • 0020194763 scopus 로고
    • Maximum Likelihood Reconstruction for Emission Tomography
    • L. Shepp, Y. Vardi; “Maximum Likelihood Reconstruction for Emission Tomography;” IEEE Trans Med Imag, Vol 1, pp 113–122, 1982.
    • (1982) IEEE Trans Med Imag , vol.1 , pp. 113-122
    • Shepp, L.1    Vardi, Y.2
  • 12
    • 0021952059 scopus 로고
    • Fast Calculation of the Exact Radiological Path for 3-D CT
    • R. Siddon; “Fast Calculation of the Exact Radiological Path for 3-D CT;” Med Phys, Vol 12, pp 252–255, 1985.
    • (1985) Med Phys , vol.12 , pp. 252-255
    • Siddon, R.1
  • 13
    • 0020702884 scopus 로고
    • Utilizing Side Information in Emission Tomography
    • D. Snyder, “Utilizing Side Information in Emission Tomography;” IEEE Trans Nucl Sci; Vol 31, 533–537, 1987.
    • (1987) IEEE Trans Nucl Sci , vol.31 , pp. 533-537
    • Snyder, D.1
  • 14
    • 0001579739 scopus 로고
    • Implementation of Simultaneous Attenuation and Detector Response Correction in SPECT
    • Feb.
    • B. Tsui, H. Hu, D. Gilland, G. T. Gullberg; “Implementation of Simultaneous Attenuation and Detector Response Correction in SPECT;” IEEE Trans Nuc Sci, Vol NS-35, pp 778–783, Feb. 1988.
    • (1988) IEEE Trans Nuc Sci , vol.NS-35 , pp. 778-783
    • Tsui, B.1    Hu, H.2    Gilland, D.3    Gullberg, G.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.