메뉴 건너뛰기




Volumn 14, Issue 3, 1990, Pages 437-445

Performance characteristics of an eight-ring whole body pet scanner

Author keywords

Attenuation Values; Emission computed tomography; Performance Evaluation; Techniques

Indexed keywords

RADIOISOTOPE;

EID: 0025355553     PISSN: 03638715     EISSN: 15323145     Source Type: Journal    
DOI: 10.1097/00004728-199005000-00022     Document Type: Article
Times cited : (187)

References (13)
  • 1
    • 0020091155 scopus 로고
    • A quad BGO detector and its timing and positioning discrimination for positron computed tomography
    • Murayama H, Nohara N, Tanaka E, Hayashi T. A quad BGO detector and its timing and positioning discrimination for positron computed tomography. Nucl Instr Meth 1982;192:501-11.
    • (1982) Nucl Instr Meth , vol.192 , pp. 501-511
    • Murayama, H.1    Nohara, N.2    Tanaka, E.3    Hayashi, T.4
  • 3
    • 84910864831 scopus 로고
    • Figures of merit for different detector configurations utilized in high resolution positron cameras
    • Eriksson L, Bergström M, Bohm Chr, et al. Figures of merit for different detector configurations utilized in high resolution positron cameras. IEEE Trans Nucl Sci 1986;NS-33:446-51.
    • (1986) IEEE Trans Nucl Sci , vol.NS-33 , pp. 446-451
    • Eriksson, L.1    Bergström, M.2    Chr, B.3
  • 4
    • 0023161642 scopus 로고
    • A preliminary evaluation of a dual crystal positron camera
    • Holte S, Ostertag H, Kesselberg M. A preliminary evaluation of a dual crystal positron camera. J Comput Assist To-mogr 1987;11:691-7.
    • (1987) J Comput Assist To-Mogr , vol.11 , pp. 691-697
    • Holte, S.1    Ostertag, H.2    Kesselberg, M.3
  • 5
    • 0005878501 scopus 로고
    • A preliminary evaluation of a positron camera system using weighted decoding of individual crystals
    • Holte S, Eriksson L, Larsson JE, et al. A preliminary evaluation of a positron camera system using weighted decoding of individual crystals. IEEE Trans Nucl Sci 1988;NS-35: 730-4.
    • (1988) IEEE Trans Nucl Sci , vol.NS-35 , pp. 730-734
    • Holte, S.1    Eriksson, L.2    Larsson, J.E.3
  • 6
    • 0003681214 scopus 로고
    • Positron emission tomography and autoradiography: Principles and applications for the brain and heart
    • Phelps ME, Mazziotta JC, Schelbert HR, eds. Positron emission tomography and autoradiography: principles and applications for the brain and heart. New York: Raven Press, 1986:237-86;493-579.
    • (1986) New York: Raven Press , vol.237 , Issue.86 , pp. 493-579
    • Phelps, M.E.1    Mazziotta, J.C.2    Schelbert, H.R.3
  • 7
    • 0023746703 scopus 로고
    • A method for postinjection PET transmission measurements with a rotating source
    • Carson RE, Daube-Witherspoon ME, Green MV. A method for postinjection PET transmission measurements with a rotating source. J Nucl Med 1988;29:1558-67.
    • (1988) J Nucl Med , vol.29 , pp. 1558-1567
    • Carson, R.E.1    Daube-Witherspoon, M.E.2    Green, M.V.3
  • 8
    • 0020660172 scopus 로고
    • Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections
    • Bergström M, Eriksson L, Bohm C, Blomqvist G, Litton J. Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections. J Corn-put Assist Tomogr 1983;7:42-50.
    • (1983) J Corn-Put Assist Tomogr , vol.7 , pp. 42-50
    • Bergström, M.1    Eriksson, L.2    Bohm, C.3    Blomqvist, G.4    Litton, J.5
  • 9
    • 0018582265 scopus 로고
    • Tomographic measurements of local cerebral glucose metabolic rate in human with (F-18)-2-fluoro-2-deoxy-D-glucose: Validation of method
    • Phelps ME, Huang SC, Hoffman EJ, Selin C, Sokoloff L, Kuhl DE. Tomographic measurements of local cerebral glucose metabolic rate in human with (F-18)-2-fluoro-2-deoxy-D-glucose: validation of method. Ann Neurol 1979;6:371-88.
    • (1979) Ann Neurol , vol.6 , pp. 371-388
    • Phelps, M.E.1    Huang, S.C.2    Hoffman, E.J.3    Selin, C.4    Sokoloff, L.5    Kuhl, D.E.6
  • 10
    • 0022416217 scopus 로고
    • Comparative regional analysis of 2-fluorodeoxyglucose and methylglucose uptake in brain of four stroke patients. With special reference to the regional estimation of the lumped constant
    • Gjedde A, Wienhard K, Heiss WD, et al. Comparative regional analysis of 2-fluorodeoxyglucose and methylglucose uptake in brain of four stroke patients. With special reference to the regional estimation of the lumped constant. J Cereb Blood Flow Metab 1985;5:163-78.
    • (1985) J Cereb Blood Flow Metab , vol.5 , pp. 163-178
    • Gjedde, A.1    Wienhard, K.2    Heiss, W.D.3
  • 12
    • 0021140061 scopus 로고
    • Regional kinetic constants and cerebral metabolic rate for glucose in normal human volunteers determined by dynamic positron emission tomography of [18F]-2-fluoro-2-deoxy-D-glucose
    • Heiss WD, Pawlick G, Herholz K, et al. Regional kinetic constants and cerebral metabolic rate for glucose in normal human volunteers determined by dynamic positron emission tomography of [18F]-2-fluoro-2-deoxy-D-glucose. J Cereb Blood Flow Metab 1984;4:212-23.
    • (1984) J Cereb Blood Flow Metab , vol.4 , pp. 212-223
    • Heiss, W.D.1    Pawlick, G.2    Herholz, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.