메뉴 건너뛰기




Volumn 25, Issue 6, 1989, Pages 1049-1059

Performance of Electronic Ballast and Controls with 34- and 40-Watt F40 Fluorescent Lamps

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC LAMPS--FLICKERING; ELECTRIC POWER FACTOR;

EID: 0024768983     PISSN: 00939994     EISSN: 19399367     Source Type: Journal    
DOI: 10.1109/28.44241     Document Type: Article
Times cited : (31)

References (10)
  • 2
    • 0020203983 scopus 로고
    • Electromagnetic interference measurements of fluorescent lamps operated with solid-state ballasts
    • Nov./Dec.
    • A. A. Arthur et al., Electromagnetic interference measurements of fluorescent lamps operated with solid-state ballasts,” IEEE Trans. Ind. Appl, vol. IA-18, no. 6, pp. 647–52, Nov./Dec. 1982.
    • (1982) IEEE Trans. Ind. Appl , vol.IA-18 , Issue.6 , pp. 647-652
    • Arthur, A.A.1
  • 3
    • 84941475584 scopus 로고
    • Fluorescent lighting, headaches and eye strain
    • private communication of report presented at National Lighting Conf.
    • A. J. Wilkens, et al., “Fluorescent lighting, headaches and eye strain,” private communication of report presented at National Lighting Conf., 1988.
    • (1988)
    • Wilkens, A.J.1
  • 4
    • 84941431183 scopus 로고
    • Experimental studies relating environmental lighting and flicker to Visual fatique in VDT operators
    • LBL report 16299, Berkeley, CA, June.
    • S. M. Berman et al., Experimental studies relating environmental lighting and flicker to Visual fatique in VDT operators,” LBL report 16299, Berkeley, CA, June 1983.
    • (1983)
    • Berman, S.M.1
  • 5
    • 0022223533 scopus 로고
    • Effect of filament power removal on fluorescent lamp systems
    • Toronto, ON, Canada, Oct.
    • R. R. Verderber, O. Morse, and F. Rubinstein, Effect of filament power removal on fluorescent lamp systems,” in Proc. IEEE IAS Conf., Toronto, ON, Canada, Oct. 1985.
    • (1985) Proc. IEEE IAS Conf.
    • Verderber, R.R.1    Morse, O.2    Rubinstein, F.3
  • 6
    • 0022185236 scopus 로고
    • Life of fluorescent lamps operated at high frequencies with solid-state ballasts
    • Toronto, ON, Canada, Oct.
    • R. R. Verderber, O. Morse, and F. Rubinstein, Life of fluorescent lamps operated at high frequencies with solid-state ballasts,” in Proc. IEEE IAS Conf., Toronto, ON, Canada, Oct. 1985.
    • (1985) Proc. IEEE IAS Conf.
    • Verderber, R.R.1    Morse, O.2    Rubinstein, F.3
  • 7
    • 0022679261 scopus 로고
    • Performance of electronic ballasts and other new lighting equipment
    • Palo Alto, CA, Mar.
    • R. R. Verderber and O. Morse, Performance of electronic ballasts and other new lighting equipment,” Electric Power Research Institute, vol. EM-4510, Palo Alto, CA, Mar. 1986.
    • (1986) Electric Power Research Institute , vol.EM-4510
    • Verderber, R.R.1    Morse, O.2
  • 8
    • 84941440702 scopus 로고
    • High frequency starting of fluorescent lamps
    • LBL Report 13290, Berkeley, CA, Sept.
    • O. Morse, High frequency starting of fluorescent lamps,” LBL Report 13290, Berkeley, CA, Sept. 1981.
    • (1981)
    • Morse, O.1
  • 9
    • 0020831790 scopus 로고
    • Fluorescent lamp starting voltage relationships at 60 Hz and high frequency
    • Oct.
    • E. E. Hammer, Fluorescent lamp starting voltage relationships at 60 Hz and high frequency,” J. Ilium. Eng. Soc, vol. 13, no. 1, p. 36, Oct. 1983.
    • (1983) J. Ilium. Eng. Soc , vol.13 , Issue.1 , pp. 36
    • Hammer, E.E.1
  • 10
    • 0022781772 scopus 로고
    • Varying voltage: its impact on fluorescent ballast systems
    • Sept./Oct.
    • S. Kalinowsky and J. J. Martello, Varying voltage: its impact on fluorescent ballast systems,” Electrical Systems Design, vol. 66, no. 5, p. 28, Sept./Oct. 1986.
    • (1986) Electrical Systems Design , vol.66 , Issue.5 , pp. 28
    • Kalinowsky, S.1    Martello, J.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.