메뉴 건너뛰기




Volumn 36, Issue 7, 1989, Pages 746-753

Functional Neuromuscular Stimulation System Using an Implantable Hydroxyapatite Connector and a Microprocessor-Based Portable Stimulator

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL ENGINEERING; COMPUTERS, MICROCOMPUTER--APPLICATIONS; ELECTRIC CONNECTORS; ELECTRODES;

EID: 0024696720     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/10.32107     Document Type: Article
Times cited : (8)

References (20)
  • 1
    • 0023588115 scopus 로고
    • Sintered hydroxyapatite for a percutaneous device and its clinical application
    • H. Aoki, M. Akao, Y. Shin, T. Tsuji, and T. Togawa, “Sintered hydroxyapatite for a percutaneous device and its clinical application.” Med. Prog. Tech., vol. 12, pp. 213–220, 1987.
    • (1987) Med. Prog. Tech. , vol.12 , pp. 213-220
    • Aoki, H.1    Akao, M.2    Shin, Y.3    Tsuji, T.4    Togawa, T.5
  • 2
    • 26844514786 scopus 로고
    • EMG-based stimulation patterns of FES for the paralyzed upper extremities
    • Dubrovnik, Yugoslavia
    • Y. Handa, A. Naito, M. Ichie, T. Handa, N. Matsushita, and N. Hoshimiya, “EMG-based stimulation patterns of FES for the paralyzed upper extremities,” in Proc. 9th Int. Symp. ECHE. Dubrovnik, Yugoslavia, 1987, pp. 329–337.
    • (1987) Proc. 9th Int. Symp. ECHE. , pp. 329-337
    • Handa, Y.1    Naito, A.2    Ichie, M.3    Handa, T.4    Matsushita, N.5    Hoshimiya, N.6
  • 3
    • 84948603241 scopus 로고
    • Clinical experiences of functional electrical stimulation in Japan
    • Dubrovnik, Yugoslavia
    • J. Kawamura, M. Matsuya, and N. Fukui, “Clinical experiences of functional electrical stimulation in Japan,” in Proc. 8th Int. Symp. ECHE. Dubrovnik, Yugoslavia, 1984, pp. 89–100.
    • (1984) Proc. 8th Int. Symp. ECHE. , pp. 89-100
    • Kawamura, J.1    Matsuya, M.2    Fukui, N.3
  • 4
    • 0020715238 scopus 로고
    • Packaging materials and techniques for implantable instruments
    • W. H. Ko and T. M. Spear, “Packaging materials and techniques for implantable instruments,” IEEE Eng. Med. Bio. Mag., vol. 6, pp. 24–38, 1987.
    • (1987) IEEE Eng. Med. Bio. Mag. , vol.6 , pp. 24-38
    • Ko, W.H.1    Spear, T.M.2
  • 5
    • 0020786844 scopus 로고
    • Gait restoration in paraplegic patients: A feasibility demonstration using multichannel surface electrode FES
    • A. Kralj, T. Bajd, R. Turk, J. Krajnik, and H. Benko, “Gait restoration in paraplegic patients: A feasibility demonstration using multichannel surface electrode FES,” J. Rehab. R&D, vol. 20, pp. 3–20, 1983.
    • (1983) J. Rehab. R&D , vol.20 , pp. 3-20
    • Kralj, A.1    Bajd, T.2    Turk, R.3    Krajnik, J.4    Benko, H.5
  • 6
    • 84948611675 scopus 로고
    • Development of a portable computerized FES controller
    • Dubrovnik, Yugoslavia
    • M. Makikawa, H. Horio, T. Hasegawa. and O. Sueda, “Development of a portable computerized FES controller,” in Proc. 9th Int. Symp. ECHE, Dubrovnik, Yugoslavia. 1987. pp. 233–247.
    • (1987) Proc. 9th Int. Symp. ECHE , pp. 233-247
    • Makikawa, M.1    Horio, H.2    Hasegawa, T.3    Sueda, O.4
  • 7
    • 0020632145 scopus 로고
    • Functional walking in paralyzed patients by means of electrical stimulation
    • E. B. Marsolais and R. Kobetic, “Functional walking in paralyzed patients by means of electrical stimulation,” Clin. Orthopaed., vol. 175, pp. 30–36, 1983.
    • (1983) Clin. Orthopaed. , vol.175 , pp. 30-36
    • Marsolais, E.B.1    Kobetic, R.2
  • 8
    • 0016031423 scopus 로고
    • The use of pure carbon for permanent percutaneous electrical connector systems
    • V. Mooney, D. B. Hartman, and D. McNeal, “The use of pure carbon for permanent percutaneous electrical connector systems,” Arch. Surg., vol. 108, pp. 148–153, 1974.
    • (1974) Arch. Surg. , vol.108 , pp. 148-153
    • Mooney, V.1    Hartman, D.B.2    McNeal, D.3
  • 9
    • 0023704807 scopus 로고
    • Current Concepts Review: Restoration of functional control by electrical stimulation in the upper extremity of the quadriplegic patient
    • P. H. Peckham, M. W. Keith, and A. A. Freehafer. “Current Concepts Review: Restoration of functional control by electrical stimulation in the upper extremity of the quadriplegic patient.” J. Bone Joint Surg., vol. 70-A, pp. 144–148, 1988.
    • (1988) J. Bone Joint Surg. , vol.70-A , pp. 144-148
    • Peckham, P.H.1    Keith, M.W.2    Freehafer, A.A.3
  • 10
    • 0019252903 scopus 로고
    • Controlled prehension and release in the C5 quadriplegic elicited by functional electrical stimulation of the paralyzed forearm musculature
    • P. H. Peckham, E. B. Marsolais, and J. T. Mortimer, “Controlled prehension and release in the C5 quadriplegic elicited by functional electrical stimulation of the paralyzed forearm musculature,” Ann. Biomed. Eng., vol. 8, pp. 369–388, 1980.
    • (1980) Ann. Biomed. Eng. , vol.8 , pp. 369-388
    • Peckham, P.H.1    Marsolais, E.B.2    Mortimer, J.T.3
  • 11
    • 13044275676 scopus 로고
    • FES assisted manipulation in quadriplegic patients
    • Dubrovnik, Yugoslavia
    • D. Rudel, T. Bajd, S. Rebersek, and L. Vodovnik. “FES assisted manipulation in quadriplegic patients,” in Proc. 7th Int. Symp. ECHE, Dubrovnik, Yugoslavia, 1984, pp. 273–282.
    • (1984) Proc. 7th Int. Symp. ECHE , pp. 273-282
    • Rudel, D.1    Bajd, T.2    Rebersek, S.3    Vodovnik, L.4
  • 12
    • 84955554928 scopus 로고
    • 18 month experience in clinic application of implantable multichannel stimulation devices for paraplegic patients
    • Dubrovnik. Yugoslavia
    • G. Schwanda, M. Frey, J. Holle. W. Mayr. and H. Thoma, “18 month experience in clinic application of implantable multichannel stimulation devices for paraplegic patients.” in Proc. 7th Int. Symp. ECHE. Dubrovnik. Yugoslavia, 1984, pp. 79–87.
    • (1984) Proc. 7th Int. Symp. ECHE. , pp. 79-87
    • Schwanda, G.1    Frey, M.2    Holle, J.3    Mayr, W.4    Thoma, H.5
  • 13
    • 0023378409 scopus 로고
    • An externally powered, multichannel, implantable stimulator for versatile control of paralyzed muscle
    • B. Smith. P. H. Peckham. M. W. Keith, and D. D. Roscoc. “An externally powered, multichannel, implantable stimulator for versatile control of paralyzed muscle.” IEEE Trans. Biomed. Eng., vol. BME-34. pp. 499–508. 1987.
    • (1987) IEEE Trans. Biomed. Eng. , vol.BME-34 , pp. 499-508
    • Smith, B.1    Peckham, P.H.2    Keith, M.W.3    Roscoc, D.D.4
  • 14
    • 0023135406 scopus 로고
    • Treatment of drop foot using an implantable peroneal under knee stimulator
    • P. Strojnik, R. Acimovic, E. Vavken, V. Simic. and U. Stanic. “Treatment of drop foot using an implantable peroneal under knee stimulator,” Scand. J. Rehab. Med., vol. 19. pp. 37–43. 1987.
    • (1987) Scand. J. Rehab. Med. , vol.19 , pp. 37-43
    • Strojnik, P.1    Acimovic, R.2    Vavken, E.3    Simic, V.4    Stanic, U.5
  • 15
    • 84948591894 scopus 로고
    • Development of a fine wire electrode to stimulate peripheral nerve branch. Intraneural electrode and hydroxyapatite skin button
    • Dubrovnik. Yugoslavia
    • T. Tamaki, K. Akazawa, K. Yoshinaga. and H. Aoki. “Development of a fine wire electrode to stimulate peripheral nerve branch. Intraneural electrode and hydroxyapatite skin button,” in Proc. 9th Int. Symp. ECHE, Dubrovnik. Yugoslavia, 1987, pp. 27–40.
    • (1987) Proc. 9th Int. Symp. ECHE , pp. 27-40
    • Tamaki, T.1    Akazawa, K.2    Yoshinaga, K.3    Aoki, H.4
  • 16
    • 0021845206 scopus 로고
    • A computer-controlled multichannel stimulation system for laboratory use in functional neuromuscular stimulation
    • G. B. Thrope, P. H. Peckham, and P. E. Crago, “A computer-controlled multichannel stimulation system for laboratory use in functional neuromuscular stimulation.” IEEE Trans. Biomed. Eng., vol. BME-32, pp. 363–370. 1985.
    • (1985) IEEE Trans. Biomed. Eng. , vol.BME-32 , pp. 363-370
    • Thrope, G.B.1    Peckham, P.H.2    Crago, P.E.3
  • 17
    • 84948600969 scopus 로고
    • Thirty months implantation of percutaneous devices made of sintered hydroxyapatite in the forearms of three volunteers
    • A. Tsuji, T. Togawa, H. Aoki. Y. Ukegawa, and Y. Shin. “Thirty months implantation of percutaneous devices made of sintered hydroxyapatite in the forearms of three volunteers.” Japan J. Artif. Organs. vol. 17, pp. 747–750. 1988.
    • (1988) Japan J. Artif. Organs. , vol.17 , pp. 747-750
    • Tsuji, A.1    Togawa, T.2    Aoki, H.3    Ukegawa, Y.4    Shin, Y.5
  • 19
    • 0021800935 scopus 로고
    • Functional electrical stimulation of the peripheral nerve for hemiplegia
    • R. L. Waters. D. R. McNeal. W. Faloon and B. Clifford, “Functional electrical stimulation of the peripheral nerve for hemiplegia.” J. Bone Joint Surg., vol. 67-A, pp. 792–793. 1985.
    • (1985) J. Bone Joint Surg. , vol.67-A , pp. 792-793
    • Waters, R.L.1    McNeal, D.R.2    Faloon, W.3    Clifford, B.4
  • 20
    • 0016829641 scopus 로고
    • Experimental correction of footdrop by electrical stimulation of peroneal nerve
    • R. L. Waters, D. R. McNeal, and J. Perry. “Experimental correction of footdrop by electrical stimulation of peroneal nerve.” J. Bone Joint Surg., vol. 57-A, pp. 1047–1054, 1975.
    • (1975) J. Bone Joint Surg. , vol.57-A , pp. 1047-1054
    • Waters, R.L.1    McNeal, D.R.2    Perry, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.