1
-
-
0022254452
-
Design and evaluation of a positron emission tomograph: HEADTOME-III
-
I.Kanno, S.Miura, S.Yamamoto, et al., “Design and evaluation of a positron emission tomograph: HEADTOME-III,” J. Comput. Assist. Tomogr. 9:931-939, 939, 1985.
-
(1985)
J. Comput. Assist. Tomogr
, vol.9
, pp. 931-939
-
-
Kanno, I.1
Miura, S.2
Yamamoto, S.3
-
2
-
-
0019450411
-
HEADTOME: a hybrid emission tomograph for single photon and positron emission imaging of the brain
-
I.Kanno, K.Uemura, S.Miura, et al., “HEADTOME: a hybrid emission tomograph for single photon and positron emission imaging of the brain,” J. Comput. Assist. Tomogr. 5:216-226, 1981.
-
(1981)
J. Comput. Assist. Tomogr
, vol.5
, pp. 216-226
-
-
Kanno, I.1
Uemura, K.2
Miura, S.3
-
3
-
-
0019525871
-
A hybrid emission computed tomograph HEADTOME II
-
Y.Hirose, Y.Ikeda, K.Higashi, et al., “A hybrid emission computed tomograph HEADTOME II,” IEEE Trans. Nucl. Sci. NS-29:520-523, 1982.
-
(1982)
IEEE Trans. Nucl. Sci. NS-
, vol.29
, pp. 520-523
-
-
Hirose, Y.1
Ikeda, Y.2
Higashi, K.3
-
4
-
-
84910844414
-
Design concepts and performances of HEADTOME, a multiring hybrid emission tomograph for the brain
-
I.Kanno, K.Uemura, S.Miura, et al., “Design concepts and performances of HEADTOME, a multiring hybrid emission tomograph for the brain,” In: Heiss WD, Phelps ME, eds. Positron emission tomography of the brain. Berlin: Springer Verlag, 46–50, 1983.
-
(1983)
In: Heiss WD, Phelps ME, eds. Positron emission tomography of the brain. Berlin: Springer Verlag
, pp. 46-50
-
-
Kanno, I.1
Uemura, K.2
Miura, S.3
-
5
-
-
0022899533
-
A BGO detector unit for a stationary high resolution positron emission tomograph,” J. Comput. Assist
-
S.Yamamoto, S.Miura, H.Ilda et al., “A BGO detector unit for a stationary high resolution positron emission tomograph,” J. Comput. Assist. Tomogr. 10:851-855, 1986.
-
(1986)
Tomogr
, vol.10
, pp. 851-855
-
-
Yamamoto, S.1
Miura, S.2
Ilda, H.3
-
6
-
-
0018455344
-
The Donner 280 crystal high resolution positron tomograph
-
S.E.Derenzo, T.F.Budinger, J.L.Cahoon, et.at., “The Donner 280 crystal high resolution positron tomograph”. IEEE Trans.Nucl. Sci. 26:2790-2793, 1979
-
(1979)
IEEE Trans. Nucl. Sci
, vol.26
, pp. 2790-2793
-
-
Derenzo, S.E.1
Budinger, T.F.2
Cahoon, J.L.3
-
7
-
-
0022978151
-
Deadtime correction method using random coincidence for PET
-
S.Yamamoto, S.Miura, I.Kanno, et al., “Deadtime correction method using random coincidence for PET,” J. Nucl. Med. 27:1925-1928, 1986.
-
(1986)
J. Nucl. Med
, vol.27
, pp. 1925-1928
-
-
Yamamoto, S.1
Miura, S.2
Kanno, I.3
-
8
-
-
0023156611
-
Quantitation in positron emission tomography: 8. Effects of nonlinear parameter estimation on functional Images
-
S.C.Huang, D.K.Mahoney and M.E.Phelps, “Quantitation in positron emission tomography: 8. Effects of nonlinear parameter estimation on functional Images.” J. Comput. Assist. Tomogr. 11:314-325, 1987.
-
(1987)
J. Comput. Assist. Tomogr
, vol.11
, pp. 314-325
-
-
Huang, S.C.1
Mahoney, D.K.2
Phelps, M.E.3
-
9
-
-
0019992105
-
Quantitation in positron emission tomography: 6. Effect of nonuniform resolution
-
E.J.Hoffman, S.C.Huang, D.Plummer et al., “Quantitation in positron emission tomography: 6. Effect of nonuniform resolution.” J. Comput. Assist. Tomogr. 6:987-999, 1982.
-
(1982)
J. Comput. Assist. Tomogr
, vol.6
, pp. 987-999
-
-
Hoffman, E.J.1
Huang, S.C.2
Plummer, D.3
-
10
-
-
0022669524
-
The effect of live time in components of a positron tomograph on image quantification
-
CJ.Thompson and E.Meyer, “The effect of live time in components of a positron tomograph on image quantification,” IEEE Trans. Nucl. Sc!. NS-34:337-343, 343, 1987.
-
(1987)
IEEE Trans. Nucl. Sci. NS-
, vol.34
, pp. 337-343
-
-
Thompson, C.J.1
Meyer, E.2
-
11
-
-
84939752000
-
Comparison of rapid parameter estimation techniques for quantlitating local metabolic rate and individal rate parameters from dynamic PET using 2-FDG
-
R.A.Koeppe, G.D.Hutchins, and J.E.Holden “Comparison of rapid parameter estimation techniques for quantlitating local metabolic rate and individal rate parameters from dynamic PET using 2-FDG. J. Nucl. Med. 27:940-941, 1986
-
(1986)
J. Nucl. Med
, vol.27
, pp. 940-941
-
-
Koeppe, R.A.1
Hutchins, G.D.2
Holden, J.E.3
|