메뉴 건너뛰기




Volumn 98, Issue 12, 1988, Pages 1292-1296

Intraoperative electrophysiologic monitoring of laryngeal muscle during thyroid surgery

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; CASE REPORT; ELECTROMYOGRAPHY; FEMALE; LARYNX MUSCLE; MALE; METHODOLOGY; PATIENT MONITORING; PRIORITY JOURNAL; THYROID SURGERY;

EID: 0024244910     PISSN: 0023852X     EISSN: 15314995     Source Type: Journal    
DOI: 10.1288/00005537-198812000-00003     Document Type: Article
Times cited : (76)

References (19)
  • 1
    • 0017764155 scopus 로고
    • Preservation of the Laryngeal Nerves During Total Thyroid Lobectomy
    • Lore, J. M., Kim, D. J. and Elias, S.: Preservation of the Laryngeal Nerves During Total Thyroid Lobectomy. Ann, Otol Rhinol. Laryngol., 86(1):777-788, 1977.
    • (1977) Ann, Otol Rhinol. Laryngol , vol.86 , Issue.1 , pp. 777-788
    • Lore, J.M.1    Kim, D.J.2    Elias, S.3
  • 2
    • 0023117986 scopus 로고
    • Early Postoperative Morbidity After Surgical Treatment of Thyroid Carcinoma
    • Van Heerden, J. V., Groh, M. A. and Grant, C. S.: Early Postoperative Morbidity After Surgical Treatment of Thyroid Carcinoma. Surgery, 101(2):224-227, 1987.
    • (1987) Surgery , vol.101 , Issue.2 , pp. 224-227
    • Van Heerden, J.V.1    Groh, M.A.2    Grant, C.S.3
  • 3
    • 0021711527 scopus 로고
    • Voice Changes After Thyroidectomy: Role of the External Laryngeal Nerve
    • Kark, A. E., Kissin, M. W., Auerbach, R., et al: Voice Changes After Thyroidectomy: Role of the External Laryngeal Nerve. Br. Med. J., 289:1412-1415, 1984.
    • (1984) Br. Med. J , vol.289 , pp. 1412-1415
    • Kark, A.E.1    Kissin, M.W.2    Auerbach, R.3
  • 4
    • 0022467822 scopus 로고
    • Anatomy of the Recurrent Laryngeal Nerve: A Redescription
    • Steinberg, J. L., Khane, G. J., Fernandes, C. M. C., et al: Anatomy of the Recurrent Laryngeal Nerve: A Redescription. J. Laryngol OtoL, 100:919-927, 1986.
    • (1986) J. Laryngol Otol , vol.100 , pp. 919-927
    • Steinberg, J.L.1    Khane, G.J.2    Fernandes, C.3
  • 5
    • 0023621167 scopus 로고
    • Surgical Anatomy of Structures Adjacent to the Thyroid Apex and Postoperative Voice Change (A Review Including Dissection)
    • Yerzingatsian, K. L.: Surgical Anatomy of Structures Adjacent to the Thyroid Apex and Postoperative Voice Change (A Review Including Dissection). J. Laryngol. OtoL, 14(Suppl.):1-13, 1987.
    • (1987) J. Laryngol. Otol , vol.14 , pp. 1-13
    • Yerzingatsian, K.L.1
  • 6
    • 0022409802 scopus 로고
    • A Simple Method for Identifying and Testing the Recurrent Laryngeal Nerve
    • James, A. G., Crocker, S., Woltering, E., et al: A Simple Method for Identifying and Testing the Recurrent Laryngeal Nerve. Surg. Gynecol. Obstet., 161:186-187, 1985.
    • (1985) Surg. Gynecol. Obstet , vol.161 , pp. 186-187
    • James, A.G.1    Crocker, S.2    Woltering, E.3
  • 7
    • 0023029879 scopus 로고
    • Recurrent Laryngeal Nerve Identification During Thyroid and Parathyroid Surgery
    • Gavilan, J. and Gavilan, C.: Recurrent Laryngeal Nerve Identification During Thyroid and Parathyroid Surgery. Arch. Otolaryngol., 112:1286-1288, 1986.
    • (1986) Arch. Otolaryngol , vol.112 , pp. 1286-1288
    • Gavilan, J.1    Gavilan, C.2
  • 8
    • 0022997239 scopus 로고
    • Functional Identification of the External Laryngeal Nerve During Thyroidectomy
    • Friedman, M. and Toriumi, D. M.: Functional Identification of the External Laryngeal Nerve During Thyroidectomy. Laryngoscope, 96:1291-1292,1986.
    • (1986) Laryngoscope , vol.96 , pp. 1291-1292
    • Friedman, M.1    Toriumi, D.M.2
  • 9
    • 0019468827 scopus 로고
    • Identification of the Motor Laryngeal Nerves—A New Electrical Stimulation Technique
    • Spahn, J. G., Bizal, J., Ferguson, S., et al: Identification of the Motor Laryngeal Nerves—A New Electrical Stimulation Technique. Laryngoscope, 91:1865-1868,1981.
    • (1981) Laryngoscope , vol.91 , pp. 1865-1868
    • Spahn, J.G.1    Bizal, J.2    Ferguson, S.3
  • 10
    • 0021140657 scopus 로고
    • En- dolaryngeal Devices for Perioperative Identification and Functional Testing of the Recurrent Nerve
    • Hvidegaard, T., Vase, P., Dalsgaard, S. C., et al: En- dolaryngeal Devices for Perioperative Identification and Functional Testing of the Recurrent Nerve. Otolaryngol Head Neck Surg., 92(3):292-294, 1984.
    • (1984) Otolaryngol Head Neck Surg , vol.92 , Issue.3 , pp. 292-294
    • Hvidegaard, T.1    Vase, P.2    Dalsgaard, S.C.3
  • 11
    • 0021222273 scopus 로고
    • A Method for Intraoperative Identification of the Recurrent Laryngeal Nerve
    • Woltering, E. A., Dumond, D., Ferrara, J., et al: A Method for Intraoperative Identification of the Recurrent Laryngeal Nerve. Am. J. Surg., 148:438-440, 1984.
    • (1984) Am. J. Surg , vol.148 , pp. 438-440
    • Woltering, E.A.1    Dumond, D.2    Ferrara, J.3
  • 12
    • 0019407837 scopus 로고
    • A Device for the Location and Protection of the Recurrent Laryngeal Nerve During Operations upon the Neck
    • Engel, P. M., Buter, H. A., Page, P. S., et al: A Device for the Location and Protection of the Recurrent Laryngeal Nerve During Operations upon the Neck. Surg. Gynecol Obstet., 152:824-826, 1981.
    • (1981) Surg. Gynecol Obstet , vol.152 , pp. 824-826
    • Engel, P.M.1    Buter, H.A.2    Page, P.S.3
  • 13
    • 0023601893 scopus 로고
    • Facial-Nerve and Vocal-Cord Monitoring During Otoneurosurgical Operations
    • Zini, C. and Gandolfi, A.: Facial-Nerve and Vocal-Cord Monitoring During Otoneurosurgical Operations. Arch. Otolaryngol., 113:1291-1293, 1987.
    • (1987) Arch. Otolaryngol , vol.113 , pp. 1291-1293
    • Zini, C.1    Gandolfi, A.2
  • 14
    • 0023099839 scopus 로고
    • Improved Preservation of Facial Nerve Function With Use of Electrical Monitoring During Removal of Acoustic Neuromas
    • Hamer, S. G., Daube, J. R., Ebersold, M. J., et al: Improved Preservation of Facial Nerve Function With Use of Electrical Monitoring During Removal of Acoustic Neuromas. Mayo Clin. Proc., 62:92-102, 1987.
    • (1987) Mayo Clin. Proc , vol.62 , pp. 92-102
    • Hamer, S.G.1    Daube, J.R.2    Ebersold, M.J.3
  • 15
    • 0022551707 scopus 로고
    • Acoustic (Loudspeaker) Facial Electromyographic Monitoring. Part I
    • Prass, R. and Luders, A.: Acoustic (Loudspeaker) Facial Electromyographic Monitoring. Part I. Neurosurgery, 19: 392-400, 1986.
    • (1986) Neurosurgery , vol.19 , pp. 392-400
    • Prass, R.1    Luders, A.2
  • 16
    • 0022373517 scopus 로고
    • Monitoring of Facial Nerve Function During Removal of Acoustic Tumors
    • Miller, A. R. and Jannetta, P. J.: Monitoring of Facial Nerve Function During Removal of Acoustic Tumors. Am. J. OtoL, 11(Suppl.):27-29, 1985.
    • (1985) Am. J. Otol , vol.11 , pp. 27-29
    • Miller, A.R.1    Jannetta, P.J.2
  • 17
    • 0022970311 scopus 로고
    • Facial Nerve Dissection by Use of Acoustic (Loudspeaker) Facial EMG Monitoring. Otolaryngol
    • Kinney, S. E. and Prass, R.: Facial Nerve Dissection by Use of Acoustic (Loudspeaker) Facial EMG Monitoring. Otolaryngol. Head Neck Surg., 95:458-463, 1986.
    • (1986) Head Neck Surg , vol.95 , pp. 458-463
    • Kinney, S.E.1    Prass, R.2
  • 18
    • 0022630583 scopus 로고
    • Electro- physiologic Monitoring of Facial Nerve During Temporal Bone Surgery
    • Hamer, S. G., Daube, J. R. and Ebersold, M. J.: Electro- physiologic Monitoring of Facial Nerve During Temporal Bone Surgery. LARYNGOSCOPE, 96:65-69, 1986.
    • (1986) LARYNGOSCOPE , vol.96 , pp. 65-69
    • Hamer, S.G.1    Daube, J.R.2    Ebersold, M.J.3
  • 19
    • 0018647970 scopus 로고
    • Recurrent Laryngeal Nerve Localization Using a Microlaryngeal Electrode
    • Davis, W. E., Rea, J. L. and Templer, J.: Recurrent Laryngeal Nerve Localization Using a Microlaryngeal Electrode. Otolaryngol. Head Neck Surg., 87:330-333,1979.
    • (1979) Otolaryngol. Head Neck Surg , vol.87 , pp. 330-333
    • Davis, W.E.1    Rea, J.L.2    Templer, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.