메뉴 건너뛰기




Volumn 35, Issue 9, 1988, Pages 740-751

Theory of Ultrasound Doppler-Spectra Velocimetry for Arbitrary Beam and Flow Configurations

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL ENGINEERING -- DIAGNOSIS; IMAGING TECHNIQUES -- MEDICAL APPLICATIONS; MECHANICAL VARIABLES MEASUREMENT -- VELOCITY; ULTRASONIC TRANSDUCERS; ULTRASONICS;

EID: 0024075775     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/10.7275     Document Type: Article
Times cited : (101)

References (12)
  • 1
    • 0011302660 scopus 로고
    • Doppler methods
    • C. R. Hill, Ed. New York: Wiley, ch. 11
    • P. J. Fish, “Doppler methods,” in Physical Principles of Medical Ultrasonics, C. R. Hill, Ed. New York: Wiley, 1986, ch. 11, pp. 338-376.
    • (1986) Physical Principles of Medical Ultrasonics , pp. 338-376
    • Fish, P.J.1
  • 3
    • 0022596414 scopus 로고
    • Influence of spectral broadening on continuous wave Doppler ultrasound spectra: A geometric approach
    • P. A. J. Bascom, R. S. C. Cobbold, and B. H. M. Roelofs, “Influence of spectral broadening on continuous wave Doppler ultrasound spectra: A geometric approach,” Ultrasound Med. Biol., vol. 12, pp. 387-395, 1986.
    • (1986) Ultrasound Med. Biol. , vol.12 , pp. 387-395
    • Bascom, P.A.J.1    Cobbold, R.S.C.2    Roelofs, B.H.M.3
  • 4
    • 84939393810 scopus 로고
    • Medical applications of Doppler spectral analysis using a normal orientation of the beam with respect to the direction of flow
    • Drexel University, Philadelphia, PA
    • J. A. Cisneros, “Medical applications of Doppler spectral analysis using a normal orientation of the beam with respect to the direction of flow,” Ph.D. dissertation, Drexel University, Philadelphia, PA 1985.
    • (1985) Ph.D. dissertation
    • Cisneros, J.A.1
  • 5
    • 0021827337 scopus 로고
    • Doppler spectral characterization of flow disturbances in the carotid with the Doppler probe at right angles to the vessel axis
    • J. A. Cisneros, V. L. Newhouse, and B. Goldberg, “Doppler spectral characterization of flow disturbances in the carotid with the Doppler probe at right angles to the vessel axis,” Ultrasound Med. Biol., vol. 11, 319-328, 1985.
    • (1985) Ultrasound Med. Biol. , vol.11 , pp. 319-328
    • Cisneros, J.A.1    Newhouse, V.L.2    Goldberg, B.3
  • 8
    • 0020752621 scopus 로고
    • Time dilation and inversion properties and the output spectrum of pulsed Doppler flowmeters
    • V. L. Newhouse and I. Amir, “Time dilation and inversion properties and the output spectrum of pulsed Doppler flowmeters,” IEEE Trans. Sonics Ultrason., vol. SU-30, pp. 174-179, 1983.
    • (1983) IEEE Trans. Sonics Ultrason. , vol.SU-30 , pp. 174-179
    • Newhouse, V.L.1    Amir, I.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.