메뉴 건너뛰기




Volumn 3, Issue 2, 1988, Pages 789-800

Prediction of overhead transmission line ampacity by stochastic and deterministic models

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC CONDUCTORS -- THERMAL EFFECTS; ELECTRIC LINES -- AERIAL CONDUCTORS; MATHEMATICAL MODELS;

EID: 0023985610     PISSN: 08858977     EISSN: 19374208     Source Type: Journal    
DOI: 10.1109/61.4319     Document Type: Article
Times cited : (71)

References (16)
  • 1
    • 0021302033 scopus 로고
    • Dynamic Thermal Line Rating, Summary and Status of the State-of-the-Art Technology
    • Seatle. Washington July 15-20
    • HOWINGTON B.S., RAMON G.J., “Dynamic Thermal Line Rating, Summary and Status of the State-of-the-Art Technology”(IEEE/PES 1984 Summer Meeting, Seatle. Washington July 15-20.1984).
    • (1984) IEEE/PES 1984 Summer Meeting
    • Howington, B.S.1    Ramon, G.J.2
  • 2
    • 0004311217 scopus 로고
    • Time Series Analysis Forecasting and Control
    • (Book, Holden-Day, 1976)
    • BOX G.E.P, JENKINS G.M.,“Time Series Analysis Forecasting and Control” (Book, Holden-Day, 1976).
    • (1976)
    • Box, G.E.P.1    Jenkins, G.M.2
  • 3
    • 84938158342 scopus 로고
    • A New Thermal Rating Approach: The Real Time Thermal Rating System for Strategic Overhead Conductor Transmission Lines, Part1, General Description and Justification of the Real Time Thermal Rating System
    • May/June, also see discussion by Conway B.J. and Murray L.C
    • DAVIS M.W. “A New Thermal Rating Approach: The Real Time Thermal Rating System for Strategic Overhead Conductor Transmission Lines, Part1, General Description and Justification of the Real Time Thermal Rating System”,(IEEE Transactions on Power Apparatus and Systems, Vol. 96, May/June 1977, also see discussion by Conway B.J. and Murray L.C.).
    • (1977) IEEE Transactions on Power Apparatus and Systems , vol.96
    • Davis, M.W.1
  • 5
    • 0020147786 scopus 로고
    • The Thermal Rating of Overhead Line Conductors, Part1. The Steady State Thermal Model
    • MORGAN V.T. “ The Thermal Rating of Overhead Line Conductors, Part1. The Steady State Thermal Model”, Power Research System, Vol. 5, 1982, pp. 119-139).
    • (1982) Power Research System , vol.5 , pp. 119-139
    • Morgan, V.T.1
  • 6
  • 7
    • 84941504377 scopus 로고
    • Calcul des chutes de tension de 1'echauffement et des efforts electrodynamiques en cas de court-circuit
    • paper no D 673
    • DALLE B., JOHANNET P. “Calcul des chutes de tension de 1'echauffement et des efforts electrodynamiques en cas de court-circuit”, (Technique de l'ingenieur, paper no D 673, 1979, pp. 1-20).
    • (1979) Technique de l'ingenieur , pp. 1-20
    • Dalle, B.1    Johannet, P.2
  • 8
    • 0020905525 scopus 로고
    • Real-Time Ampacity Model for Overhead Lines
    • New York
    • BLACK W.Z., BYRD W.R.,“Real-Time Ampacity Model for Overhead Lines”, IEEE/PES Winter Meeting, 1983 New York).
    • (1983) IEEE/PES Winter Meeting
    • Black, W.Z.1    Byrd, W.R.2
  • 9
    • 0020764636 scopus 로고
    • Dynamic Thermal Line Rating, Part 1, Dynamic Ampacity Rating Algorithm
    • June
    • STEPHEN D. FOSS, Sheng H.Lin, Roosevelt A. Fernandez, “Dynamic Thermal Line Rating, Part 1, Dynamic Ampacity Rating Algorithm”,(IEEE Transactions on Power Apparatus and Systems, Vol. PAS-102, No. 6, June 1983).
    • (1983) IEEE Transactions on Power Apparatus and Systems , vol.PAS-102 , Issue.6
    • Foss, S.D.1    Lin, S.H.2    Fernandez, R.A.3
  • 10
    • 84941498724 scopus 로고
    • Short-Term Forecasting of Electric Power System Load from a Weather-Dependent Model
    • Melbourne, 21-25 February
    • PANUSKA V., “Short-Term Forecasting of Electric Power System Load from a Weather-Dependent Model”,(IFAC Symposium 1977, Melbourne, 21-25 February 1977).
    • (1977) IFAC Symposium
    • Panuska, V.1
  • 11
  • 12
    • 49249153991 scopus 로고
    • An Approach to Modelling Seasonally Stationary Time-Series
    • PARZEN E., PAGANO M.,“An Approach to Modelling Seasonally Stationary Time-Series”, (Journal Econometrics, 9, 1979, pp. 137-153).
    • (1979) Journal Econometrics, 9 , pp. 137-153
    • Parzen, E.1    Pagano, M.2
  • 13
    • 0015398087 scopus 로고
    • Effect of levated Temperature peration on the Strength of Aluminum Conductors
    • New York, N.W., January 30-February 4
    • HARVEY J.R, “Effect of levated Temperature peration on the Strength of Aluminum Conductors”, (IEEE/PES Winter Meeting, New York, N.W., January 30-February 4, 1972).
    • (1972) IEEE/PES Winter Meeting
    • Harvey, J.R.1
  • 14
    • 0018468041 scopus 로고
    • The Loss of Tensile Strength of Hard Drawn Conductors by Annealing in Service
    • MORGAN V.T., “The Loss of Tensile Strength of Hard Drawn Conductors by Annealing in Service”, (IEEE Transactions on Power Apparatus and Systems, Vol. 98, 1979, pp. 700-709)
    • (1979) (IEEE Transactions on Power Apparatus and Systems , vol.98 , pp. 700-709
    • Morgan, V.T.1
  • 15
    • 84941518541 scopus 로고
    • Permanent Elongation of Conductors. Predictor Equations and Evaluation Methods
    • Cigre Report No. 22-17, WG-05-07
    • “Permanent Elongation of Conductors. Predictor Equations and Evaluation Methods”, (Cigre Report No. 22-17, WG-05-07, 1977).
    • (1977)