1
-
-
85005209726
-
AIUM/NEMA Standards Publ. UL1-1981 ‘in J. Ultrasound Med. ‘Suppl.’
-
’.
-
Safety Standard for Diagnostic Ultrasound Equipment, AIUM/NEMA Standards Publ. UL1-1981 ‘in J. Ultrasound Med. ‘Suppl.’, vol. 2, pp. S1-S50, 1983’.
-
(1983)
Safety Standard for Diagnostic Ultrasound Equipment
, vol.2
, pp. S1-S50
-
-
-
2
-
-
84939350567
-
Measurement and characterization of ultrasound fields using hydrophones in the frequency range 0.5 MHz to 15 MHz”
-
Int. Elec-trotech. Commission, Technical Committee 29: Electroacoustics, Subcommittee 29D: Ultrasonics, Aug.
-
“Measurement and characterization of ultrasound fields using hydrophones in the frequency range 0.5 MHz to 15 MHz”, Draft, Int. Elec-trotech. Commission, Technical Committee 29: Electroacoustics, Subcommittee 29D: Ultrasonics, Aug. 1985.
-
(1985)
Draft
-
-
-
3
-
-
0022411589
-
A discussion of procedures for ultrasonic intensity and power calculations from miniature hydrophone measurements”
-
G. R. Harris, “A discussion of procedures for ultrasonic intensity and power calculations from miniature hydrophone measurements”, Ultrasound Med. Biol., vol. 11, pp. 803–817, 1985.
-
(1985)
Ultrasound Med. Biol.
, vol.11
, pp. 803-817
-
-
Harris, G.R.1
-
4
-
-
0019610662
-
Miniature piezoelectric polymer ultrasonic hydrophone probes”
-
P. A. Lewin, “Miniature piezoelectric polymer ultrasonic hydrophone probes”, Ultrason., vol. 19, pp. 213–216, 1981.
-
(1981)
Ultrason.
, vol.19
, pp. 213-216
-
-
Lewin, P.A.1
-
5
-
-
0019543354
-
Piezoelectric polymer probe for ultrasonic applications”
-
A. S. DeReggi, S. C. Roth, J. M. Kenney, S. Edelman, and G. R. Harris, “Piezoelectric polymer probe for ultrasonic applications”, J. Acoust. Soc. Amer., vol. 69, pp. 853–859, 1981.
-
(1981)
J. Acoust. Soc. Amer.
, vol.69
, pp. 853-859
-
-
DeReggi, A.S.1
Roth, S.C.2
Kenney, J.M.3
Edelman, S.4
Harris, G.R.5
-
6
-
-
0019925765
-
Characteristics of a pvdf membrane hydrophone for use in the range 1-100 MHz”
-
Jan.
-
D. R. Bacon, “Characteristics of a pvdf membrane hydrophone for use in the range 1-100 MHz”, IEEE Trans. Sonics Ultrason., vol. SU-29, pp. 18–25, Jan. 1982.
-
(1982)
IEEE Trans. Sonics Ultrason.
, vol.SU-29
, pp. 18-25
-
-
Bacon, D.R.1
-
7
-
-
0020330145
-
Sensitivity considerations for PVDF hydrophones using the spot-poled membrane design”
-
Nov.
-
G. R. Harris, “Sensitivity considerations for PVDF hydrophones using the spot-poled membrane design”, IEEE Trans. Sonics Ultrason., vol. SU-29, pp. 370–377, Nov. 1982.
-
(1982)
IEEE Trans. Sonics Ultrason.
, vol.SU-29
, pp. 370-377
-
-
Harris, G.R.1
-
8
-
-
0020799628
-
PVDF membrane hydrophone performance properties and their relevance to the measurement of the acoustic output of medical ultrasonic equipment”
-
R. C. Preston, D. R. Bacon, A. J. Livett, and K. Rajendran, “PVDF membrane hydrophone performance properties and their relevance to the measurement of the acoustic output of medical ultrasonic equipment”, J. Phys. E: Sci. Instrum., vol. 16, pp. 786–796, 1983.
-
(1983)
J. Phys. E: Sci. Instrum.
, vol.16
, pp. 786-796
-
-
Preston, R.C.1
Bacon, D.R.2
Livett, A.J.3
Rajendran, K.4
-
9
-
-
0022060042
-
A polyvinylidene fluoride needle hydrophone for ultrasonic applications”
-
M. Platte, “A polyvinylidene fluoride needle hydrophone for ultrasonic applications”, Ultrason., vol. 23, pp. 113–118, 1985.
-
(1985)
Ultrason.
, vol.23
, pp. 113-118
-
-
Platte, M.1
-
10
-
-
2942666733
-
The importance of the frequency response of a hydrophone when characterising medical ultrasonic fields”
-
part 2
-
R. A. Smith, “The importance of the frequency response of a hydrophone when characterising medical ultrasonic fields”, Proc. Inst, of Acoustics, vol. 8, part 2, pp. 119–128, 1986.
-
(1986)
Proc. Inst, of Acoustics
, vol.8
, pp. 119-128
-
-
Smith, R.A.1
-
11
-
-
0013687816
-
Use of miniature hydrophones to determine peak intensities typical of medical ultrasound devices”
-
May
-
D. G. Shombert and G. R. Harris, “Use of miniature hydrophones to determine peak intensities typical of medical ultrasound devices”, IEEE Trans. Ultrason. Ferroelec. Freq. Contr., vol. UFFC-33, pp. 287–294, May 1986.
-
(1986)
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, vol.UFFC-33
, pp. 287-294
-
-
Shombert, D.G.1
Harris, G.R.2
-
12
-
-
0019968294
-
Angular response of miniature ultrasonic hydrophones”
-
D. G. Shombert, S. W. Smith, and G. R. Harris, “Angular response of miniature ultrasonic hydrophones”, Med. Phys., vol. 9, pp. 484492, 1982.
-
(1982)
Med. Phys.
, vol.9
, pp. 484492
-
-
Shombert, D.G.1
Smith, S.W.2
Harris, G.R.3
-
13
-
-
0022152555
-
A pulsed nearfield technique for measuring the directional characteristics of acoustic receivers”
-
Nov.
-
G. R. Harris and D. G. Shombert, “A pulsed nearfield technique for measuring the directional characteristics of acoustic receivers”, IEEE Trans. Sonics Ultrason., vol. SU-32, pp. 802–808, Nov. 1985.
-
(1985)
IEEE Trans. Sonics Ultrason.
, vol.SU-32
, pp. 802-808
-
-
Harris, G.R.1
Shombert, D.G.2
-
14
-
-
0038076602
-
Calibration and performance evaluation of miniature ultrasonic hydrophones using time delay spectrometry”
-
P. A. Lewin, “Calibration and performance evaluation of miniature ultrasonic hydrophones using time delay spectrometry”, in Proc. IEEE Ultrason. Symp., 1981, pp. 660-663.
-
Proc. IEEE Ultrason. Symp.
, vol.1981
, pp. 660-663
-
-
Lewin, P.A.1
-
16
-
-
0023156686
-
Factors affecting the choice of preamplification for ultrasonic hydrophone probes”
-
P. A. Lewin, M. E. Schafer, and R. C. Chivers, “Factors affecting the choice of preamplification for ultrasonic hydrophone probes”, Ultrasound Med. Biol., vol. 13, pp. 141–148, 1987.
-
(1987)
Ultrasound Med. Biol.
, vol.13
, pp. 141-148
-
-
Lewin, P.A.1
Schafer, M.E.2
Chivers, R.C.3
-
17
-
-
84939377340
-
Applications for a new Ultrahigh speed buffer”
-
Appl. Note 48, National Semiconductor, Aug.
-
B. Siegel and L. Van der Gaag, “Applications for a new Ultrahigh speed buffer”, Appl. Note 48, National Semiconductor, Aug. 1971.
-
(1971)
-
-
Siegel, B.1
Van der Gaag, L.2
-
19
-
-
0003711146
-
-
New York: McGraw-Hill
-
J. Millman and H. Taub, Pulse, Digital, and Switching Waveforms. New York: McGraw-Hill, 1965, pp. 42-44.
-
(1965)
Pulse, Digital, and Switching Waveforms
, pp. 42-44
-
-
Millman, J.1
Taub, H.2
-
20
-
-
0003748537
-
Biological effects of ultrasound: Mechanisms and clinical applications”
-
Bethesda, MD, NCRP Rep. 74
-
“Biological effects of ultrasound: Mechanisms and clinical applications”, Nat. Council on Radiation Protection and Measurements, Bethesda, MD, NCRP Rep. 74, 1983.
-
(1983)
Nat. Council on Radiation Protection and Measurements
-
-
-
21
-
-
0002017403
-
Patient exposure data for Doppler ultrasound”
-
Basic Doppler Cardiology
-
H. F. Stewart, P. X. Silvis, and S. W. Smith, “Patient exposure data for Doppler ultrasound”, in Clinics in Diagnostic Ultrasound, vol. 34, Basic Doppler Cardiology 1986, pp. 187–195.
-
(1986)
Clinics in Diagnostic Ultrasound
, vol.34
, pp. 187-195
-
-
Stewart, H.F.1
Silvis, P.X.2
Smith, S.W.3
-
22
-
-
0022395774
-
The output of pulse-echo ultrasound equipment: A survey of powers, pressures, and intensities”
-
F. A. Duck, H. C. Starritt, J. D. Aindow, M. A. Perkins, and A. J. Hawkins, “The output of pulse-echo ultrasound equipment: A survey of powers, pressures, and intensities”, Brit. J. Rad., vol. 58, pp. 989–1001, 1985.
-
(1985)
Brit. J. Rad.
, vol.58
, pp. 989-1001
-
-
Duck, F.A.1
Starritt, H.C.2
Aindow, J.D.3
Perkins, M.A.4
Hawkins, A.J.5
-
23
-
-
0023288114
-
A survey of the acoustic output of ultrasonic Doppler equipment”
-
F. A. Duck, H. C. Starritt, and S. P. Anderson, “A survey of the acoustic output of ultrasonic Doppler equipment”, Clinical Phys. Physiol. Meas., vol. 8, pp. 39–49, 1987.
-
(1987)
Clinical Phys. Physiol. Meas.
, vol.8
, pp. 39-49
-
-
Duck, F.A.1
Starritt, H.C.2
Anderson, S.P.3
-
24
-
-
84939388562
-
510‘k’ guide for measuring and reporting acoustic output of diagnostic ultrasound medical devices”
-
Center for Devices and Radiological Health, Dec.
-
“510‘k’ guide for measuring and reporting acoustic output of diagnostic ultrasound medical devices”, Food and Drug Administration, Center for Devices and Radiological Health, Dec. 1985.
-
(1985)
Food and Drug Administration
-
-
-
25
-
-
0022612657
-
The locations of peak pressures and peak intensities in finite amplitude beams from a pulsed focused transducer”
-
F. A. Duck and H. C. Starritt, “The locations of peak pressures and peak intensities in finite amplitude beams from a pulsed focused transducer”, Ultrasound Med. Biol., vol. 12, pp. 403–409, 1986.
-
(1986)
Ultrasound Med. Biol.
, vol.12
, pp. 403-409
-
-
Duck, F.A.1
Starritt, H.C.2
-
26
-
-
84939323017
-
Measurement of I spta and I spta from RealTime scanning machines”
-
part 2
-
K. Martin, “Measurement of Ispta and Ispta from RealTime scanning machines”, Proc. Inst. Acoustics, vol. 8, part 2, pp. 129–135, 1986.
-
(1986)
Proc. Inst. Acoustics
, vol.8
, pp. 129-135
-
-
Martin, K.1
-
27
-
-
0021262046
-
Finite amplitude distortion of the pulsed fields used in diagnostic ultrasound”
-
D. R. Bacon, “Finite amplitude distortion of the pulsed fields used in diagnostic ultrasound”, Ultrasound Med. Biol., vol. 10, pp. 189195, 1984.
-
(1984)
Ultrasound Med. Biol.
, vol.10
, pp. 189195
-
-
Bacon, D.R.1
-
29
-
-
84939320805
-
Calibration of medical ultrasonic equipment-Procedures and accuracy assessment”
-
R. C. Preston, D. R. Bacon, and R. A. Smith, “Calibration of medical ultrasonic equipment-Procedures and accuracy assessment”, IEEE Trans. Ultrason. Ferroelec. Freq. Contr., this issue, pp. 110121.
-
IEEE Trans. Ultrason. Ferroelec. Freq. Contr., this issue
, pp. 110121
-
-
Preston, R.C.1
Bacon, D.R.2
Smith, R.A.3
|