1
-
-
84939389481
-
Safely standard for diagnostic ultrasound equipment
-
Washington, DC, Publication UL 1-
-
AIUM/NEMA, “Safely standard for diagnostic ultrasound equipment,” Nat. Elec. Manuf. Assoc., Washington, DC, Publication UL 1–1981.
-
(1981)
Nat. Elec. Manuf. Assoc.
-
-
-
2
-
-
0019957405
-
A comparison of two calibration methods for ultrasonic hydrophones
-
W.B. Gloersen, G.R. Harris, H.F. Stewart, and P.A. Lewin, “A comparison of two calibration methods for ultrasonic hydrophones,” Ultrasound Med. Biol., vol. 8, pp. 545–548, 1982.
-
(1982)
Ultrasound Med. Biol.
, vol.8
, pp. 545-548
-
-
Gloersen, W.B.1
Harris, G.R.2
Stewart, H.F.3
Lewin, P.A.4
-
3
-
-
0023983340
-
Primary calibration of ultrasonic hydrophones using optical interferometry
-
this issue
-
D.R. Bacon, “Primary calibration of ultrasonic hydrophones using optical interferometry,” IEEE Trans. Ultrason. Ferroelec. Freq. Contr., this issue, pp. 152–161.
-
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, pp. 152-161
-
-
Bacon, D.R.1
-
4
-
-
0019925765
-
Characteristics of a pvdf membrane hydrophone for use in the range 1-100 MHz
-
D.R. Bacon, “Characteristics of a pvdf membrane hydrophone for use in the range 1-100 MHz,” IEEE Trans. Sonics Ultrason., vol. SU-29, pp. 18–25, 1982.
-
(1982)
IEEE Trans. Sonics Ultrason.
, vol.29 SU
, pp. 18-25
-
-
Bacon, D.R.1
-
5
-
-
0020799628
-
PVDF membrane hydrophone performance properties and their relevance to the measurement of the acoustic output of medical ultrasonic equipment
-
R.C. Preston, D.R. Bacon, A.J. Livett, and K. Rajendran, “PVDF membrane hydrophone performance properties and their relevance to the measurement of the acoustic output of medical ultrasonic equipment,” J. Phys. E: Sci. Instrum., vol. 16, pp. 786–796, 1983.
-
(1983)
J. Phys. E: Sci. Instrum.
, vol.16
, pp. 786-796
-
-
Preston, R.C.1
Bacon, D.R.2
Livett, A.J.3
Rajendran, K.4
-
6
-
-
0019610662
-
Miniature piezoelectric polymer ultrasonic hydrophone probes
-
P.A. Lewin, “Miniature piezoelectric polymer ultrasonic hydrophone probes,” Ultrasonics, vol. 19, pp. 213–216, 1981.
-
(1981)
Ultrasonics
, vol.19
, pp. 213-216
-
-
Lewin, P.A.1
-
7
-
-
0017025438
-
Ultrasonic standard probe transducers
-
K. Brendel and G. Ludwig, “Ultrasonic standard probe transducers,” Acustica, vol. 36, pp. 203–208, 1976.
-
(1976)
Acustica
, vol.36
, pp. 203-208
-
-
Brendel, K.1
Ludwig, G.2
-
8
-
-
0016937136
-
Concepts in the frequency and time domain response of loudspeakers
-
R. Heyser, “Concepts in the frequency and time domain response of loudspeakers,” Monitor, Proc. IEEE, pp. 66–76, 1976.
-
(1976)
Monitor, Proc. IEEE
, pp. 66-76
-
-
Heyser, R.1
-
9
-
-
0038076602
-
Calibration and performance evaluation of miniature ultrasonic hydrophones using time delay spectrometry
-
P.A. Lewin, “Calibration and performance evaluation of miniature ultrasonic hydrophones using time delay spectrometry,” in Proc. 1981 IEEE Ultrason. Symp., 1981, pp. 660–664.
-
(1981)
Proc. 1981 IEEE Ultrason. Symp.
, pp. 660-664
-
-
Lewin, P.A.1
-
11
-
-
0021262046
-
Finite amplitude distortion of the pulsed fields used in diagnostic ultrasound
-
D.R. Bacon, “Finite amplitude distortion of the pulsed fields used in diagnostic ultrasound,” Ultrasound Med. Biol., vol. 10, pp. 189195, 1984.
-
(1984)
Ultrasound Med. Biol.
, vol.10
, pp. 189-195
-
-
Bacon, D.R.1
-
12
-
-
0023978509
-
The influence of nonlinear fields on miniature hydrophone calibration using the planar scanning technique
-
this issue
-
S.S. Corbett, III, “The influence of nonlinear fields on miniature hydrophone calibration using the planar scanning technique,” IEEE Trans. Ultrason. Ferroelec. Freq. Contr., this issue, pp. 162–167.
-
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, pp. 162-167
-
-
Corbett, S.S.1
-
13
-
-
0021390175
-
An ultrasonic absolute power transfer standard
-
S.E. Fick, F.R. Breckenridge, C.E. Tschiegg, and D.G. Eitzen, “An ultrasonic absolute power transfer standard,” J. Res. NBS, vol. 89, pp. 209–212, 1984.
-
(1984)
J. Res. NBS
, vol.89
, pp. 209-212
-
-
Fick, S.E.1
Breckenridge, F.R.2
Tschiegg, C.E.3
Eitzen, D.G.4
-
14
-
-
0020203548
-
Calibration of miniature ultrasonic receivers using a planar scanning technique
-
B.A. Herman and G.R. Harris, “Calibration of miniature ultrasonic receivers using a planar scanning technique,” J. Acoust. Soc. Amer., vol. 72, pp. 1357–1363, 1982.
-
(1982)
J. Acoust. Soc. Amer.
, vol.72
, pp. 1357-1363
-
-
Herman, B.A.1
Harris, G.R.2
-
15
-
-
0018305397
-
Ultrasonic transducer characterisation at the NBS
-
E.B. Miller and D.G. Eitzen, “Ultrasonic transducer characterisation at the NBS,” IEEE Trans. Sonics Ultrason., vol. SU-26, pp. 2837, 1979.
-
(1979)
IEEE Trans. Sonics Ultrason.
, vol.26 SU
, pp. 28-37
-
-
Miller, E.B.1
Eitzen, D.G.2
-
16
-
-
0017512712
-
A primary method for the determination of ultrasonic intensity with the elastic sphere radiometer
-
F. Dunn, A.J. Averbuck, and W.D. O'Brien, “A primary method for the determination of ultrasonic intensity with the elastic sphere radiometer,” Acustica, vol. 38, pp. 58–61, 1977.
-
(1977)
Acustica
, vol.38
, pp. 58-61
-
-
Dunn, F.1
Averbuck, A.J.2
O'Brien, W.D.3
-
17
-
-
84911558244
-
Measurement and characterisation of ultrasonic fields using hydrophones in the frequency range 0.5 MHz to 15 MHz
-
TC87 document 87(Secretariat)2 (formerly SC29D document 29D(Secrectariat)26)
-
IEC, “Measurement and characterisation of ultrasonic fields using hydrophones in the frequency range 0.5 MHz to 15 MHz,” Int. Elec-trotech. Commission, TC87 document 87(Secretariat)2 (formerly SC29D document 29D(Secrectariat)26), 1987.
-
(1987)
Int. Elec-trotech. Commission
-
-
-
18
-
-
84939320805
-
Calibration of medical ultrasonic equipment-Procedures and accuracy assessment
-
this issue
-
R.C. Preston, D.R. Bacon, and R.A. Smith, “Calibration of medical ultrasonic equipment-Procedures and accuracy assessment,” IEEE Trans. Ultrason. Ferroelec. Freq. Contr., this issue, pp. 110121.
-
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, pp. 110121
-
-
Preston, R.C.1
Bacon, D.R.2
Smith, R.A.3
-
19
-
-
84910695489
-
Finite amplitude propagation in acoustic beams
-
Ph.D. dissertation
-
D.R. Bacon, “Finite amplitude propagation in acoustic beams,” Ph.D. dissertation, Univ. of Bath, UK, 1986.
-
(1986)
Univ. of Bath, UK
-
-
Bacon, D.R.1
-
20
-
-
2942666733
-
The importance of the frequency response of a hydrophone when characterising medical ultrasonic fields
-
R.A. Smith, “The importance of the frequency response of a hydrophone when characterising medical ultrasonic fields,” Proc. Inst. Acoust., vol. 8, pp. 119–128, 1986.
-
(1986)
Proc. Inst. Acoust.
, vol.8
, pp. 119-128
-
-
Smith, R.A.1
-
21
-
-
84939372189
-
Acoustic output measurement and labeling standard for diagnostic ultrasonic equipment
-
Washington, DC
-
AIUM/NEMA, “Acoustic output measurement and labeling standard for diagnostic ultrasonic equipment,” Nat. Elec. Manuf. Assoc., Washington, DC, 1988.
-
(1988)
Nat. Elec. Manuf. Assoc.
-
-
|