메뉴 건너뛰기




Volumn 8, Issue 6, 1988, Pages 279-290

New Jersey Low Contact Stress Total Ankle Replacement: Biomechanical Rationale and Review of 23 Cementless Cases

Author keywords

[No Author keywords available]

Indexed keywords

ANKLE; BIOMECHANICS; CLINICAL ARTICLE; DISLOCATION; DYSTROPHY; HUMAN; INFECTION; JOINT PROSTHESIS; SYMPATHETIC REFLEX; WOUND HEALING;

EID: 0023916789     PISSN: 10711007     EISSN: 19447876     Source Type: Journal    
DOI: 10.1177/107110078800800603     Document Type: Article
Times cited : (148)

References (53)
  • 2
    • 76949120347 scopus 로고
    • The axis of rotation at the ankle joint in man: its influence upon the form of the talus and the mobility of the fibula
    • Barnett C.H. Napier J.R.: The axis of rotation at the ankle joint in man: its influence upon the form of the talus and the mobility of the fibula. J. Anat., 86: 1–8, 1952.
    • (1952) J. Anat. , vol.86 , pp. 1-8
    • Barnett, C.H.1    Napier, J.R.2
  • 3
    • 0018970317 scopus 로고
    • The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone
    • Bobyn J.D. Pilliar R.M. Cameron H.U. Weatherly G.C.: The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone. Clin. Orthop., 150: 263–270, 1980.
    • (1980) Clin. Orthop. , vol.150 , pp. 263-270
    • Bobyn, J.D.1    Pilliar, R.M.2    Cameron, H.U.3    Weatherly, G.C.4
  • 4
    • 0022196413 scopus 로고
    • Total ankle arthroplasty: a long-term review of the London Hospital experience
    • Bolton-Maggs B.G. Sudlow R.A. Freeman M.A.R.: Total ankle arthroplasty: a long-term review of the London Hospital experience. J. Bone Joint Surg., 67B: 785–790, 1985.
    • (1985) J. Bone Joint Surg. , vol.67B , pp. 785-790
    • Bolton-Maggs, B.G.1    Sudlow, R.A.2    Freeman, M.A.R.3
  • 8
    • 0022892456 scopus 로고
    • The New Jersey low-contact-stress knee replacement system: biomechanical rationale and review of the first 123 cemented cases
    • Buechel F.F. Pappas M.J.: The New Jersey low-contact-stress knee replacement system: biomechanical rationale and review of the first 123 cemented cases. Arch. Orthop. Trauma Surg., 105: 197–204, 1986.
    • (1986) Arch. Orthop. Trauma Surg. , vol.105 , pp. 197-204
    • Buechel, F.F.1    Pappas, M.J.2
  • 9
    • 0018199977 scopus 로고
    • Floating-socket” total shoulder replacement: anatomical, biomechanical, and surgical rationale
    • Buechel F.F. Pappas M.J. De-Palma A.F.: “Floating-socket” total shoulder replacement: anatomical, biomechanical, and surgical rationale. J. Biomed. Mater. Res., 12: 89–114, 1978.
    • (1978) J. Biomed. Mater. Res. , vol.12 , pp. 89-114
    • Buechel, F.F.1    Pappas, M.J.2    De-Palma, A.F.3
  • 10
    • 0022534681 scopus 로고
    • Effect of surface replacement arthroplasty on stability of the ankle
    • Burge P. Evans M.: Effect of surface replacement arthroplasty on stability of the ankle. Foot Ankle, 7: 10–17, 1986.
    • (1986) Foot Ankle , vol.7 , pp. 10-17
    • Burge, P.1    Evans, M.2
  • 13
  • 14
    • 0018898170 scopus 로고
    • Evaluation of the early result of Smith total ankle replacement
    • Dini A.A. Bassett F.H. 3d: Evaluation of the early result of Smith total ankle replacement. Clin. Orthop., 146: 228–230, 1980.
    • (1980) Clin. Orthop. , vol.146 , pp. 228-230
    • Dini, A.A.1    Bassett, F.H.2
  • 15
    • 0020524990 scopus 로고
    • Hip arthroplasty with a Moore prosthesis with porous coating: a five-year study
    • Engh C.A.: Hip arthroplasty with a Moore prosthesis with porous coating: a five-year study. Clin. Orthop., 176: 52–66, 1983.
    • (1983) Clin. Orthop. , vol.176 , pp. 52-66
    • Engh, C.A.1
  • 16
    • 0017430726 scopus 로고
    • Management of arthritis of the ankle: an alternative of arthrodesis
    • Evanski P.H. Waugh T.R.: Management of arthritis of the ankle: an alternative of arthrodesis. Clin. Orthop., 122: 110–115, 1977.
    • (1977) Clin. Orthop. , vol.122 , pp. 110-115
    • Evanski, P.H.1    Waugh, T.R.2
  • 18
    • 0017201962 scopus 로고
    • Current state of total joint replacement
    • Freeman M.A.: Current state of total joint replacement. Br. Med. J., 2: 1301–1304, 1976.
    • (1976) Br. Med. J. , vol.2 , pp. 1301-1304
    • Freeman, M.A.1
  • 19
    • 0018087555 scopus 로고
    • The mechanics of the knee and prosthesis design
    • Goodfellow J. O'Connor J.: The mechanics of the knee and prosthesis design. J. Bone Joint Surg., 60B: 358–369, 1978.
    • (1978) J. Bone Joint Surg. , vol.60B , pp. 358-369
    • Goodfellow, J.1    O'Connor, J.2
  • 20
    • 0016951966 scopus 로고
    • A bioengineering analysis of force actions at the knee in normal and pathological gait
    • Harrington I.J.: A bioengineering analysis of force actions at the knee in normal and pathological gait. Biomed. Eng., 11: 167–172, 1976.
    • (1976) Biomed. Eng. , vol.11 , pp. 167-172
    • Harrington, I.J.1
  • 27
    • 0016968013 scopus 로고
    • The pathology of the joint tissues and its clinical relevance in prosthesis failure
    • Mirra J.M. Amstutz H.C. Matos M. Gold R.: The pathology of the joint tissues and its clinical relevance in prosthesis failure. Clin. Orthop., 117: 221–240, 1976.
    • (1976) Clin. Orthop. , vol.117 , pp. 221-240
    • Mirra, J.M.1    Amstutz, H.C.2    Matos, M.3    Gold, R.4
  • 29
    • 0018500553 scopus 로고
    • An artificial ankle joint
    • Newton S.E. 3d: An artificial ankle joint. Clin. Orthop., 142: 141–145, 1979.
    • (1979) Clin. Orthop. , vol.142 , pp. 141-145
    • Newton, S.E.1
  • 30
    • 0020070910 scopus 로고
    • Total ankle arthroplasty: clinical study of fifty cases
    • Newton S.E. 3d: Total ankle arthroplasty: clinical study of fifty cases. J. Bone Joint Surg., 64A: 104–111, 1982.
    • (1982) J. Bone Joint Surg. , vol.64A , pp. 104-111
    • Newton, S.E.1
  • 33
    • 0017185121 scopus 로고
    • Cylindrical total ankle joint replacement: surgical and biomechanical rationale
    • Pappas M. Buechel F.F. De-Palma A.F.: Cylindrical total ankle joint replacement: surgical and biomechanical rationale. Clin. Orthop., 118: 82–92, 1976.
    • (1976) Clin. Orthop. , vol.118 , pp. 82-92
    • Pappas, M.1    Buechel, F.F.2    De-Palma, A.F.3
  • 34
    • 0343945919 scopus 로고
    • Evaluation of contact stresses in metal-plastic total knee replacements
    • Pizzoferrato A., Marchetti P.G., Ravaglioli A., Lee A.J.C.,(eds. Amsterdam Elsevier Science Publishers
    • Pappas M.J. Makris G. Buechel F.F.: Evaluation of contact stresses in metal-plastic total knee replacements. In Biomaterials and Clinical Applications. Pizzoferrato A., Marchetti P.G., Ravaglioli A., Lee A.J.C.,(eds. ), Amsterdam, Elsevier Science Publishers, 1987, pp. 259–262.
    • (1987) Biomaterials and Clinical Applications , pp. 259-262
    • Pappas, M.J.1    Makris, G.2    Buechel, F.F.3
  • 36
    • 77949504506 scopus 로고
    • Loading on normal hip and knee joints and on joint replacements
    • Schaldach M. et al. (eds) Berlin Springer
    • Paul J.P.: Loading on normal hip and knee joints and on joint replacements. In Advances in Artificial Hip and Knee Joint Technology. Schaldach M. et al. (eds), Berlin, Springer, 1976, pp. 53–70.
    • (1976) Advances in Artificial Hip and Knee Joint Technology , pp. 53-70
    • Paul, J.P.1
  • 39
    • 0009626883 scopus 로고
    • Göteborg, Sweden Department of Orthopaedic Surgery, University of Göteborg A. B. Litotyp,
    • Rydell N.W.: Forces on the Femoral Head-Prosthesis. Göteborg, Sweden, Department of Orthopaedic Surgery, University of Göteborg, A. B. Litotyp, 1966.
    • (1966) Forces on the Femoral Head-Prosthesis
    • Rydell, N.W.1
  • 41
    • 0020447351 scopus 로고
    • Development and evolution of the ICLH ankle replacement
    • Samuelson K.M. Freeman M.A. Tuke M.A.: Development and evolution of the ICLH ankle replacement. Foot Ankle, 3: 32–36, 1982.
    • (1982) Foot Ankle , vol.3 , pp. 32-36
    • Samuelson, K.M.1    Freeman, M.A.2    Tuke, M.A.3
  • 43
    • 0016927763 scopus 로고
    • Total ankle joint replacement as an alternative to arthrodesis
    • Stauffer R.N.: Total ankle joint replacement as an alternative to arthrodesis. Geriatrics, 31: 79–82, 85, 1976.
    • (1976) Geriatrics , vol.31 , pp. 79-82
    • Stauffer, R.N.1
  • 44
    • 0017716717 scopus 로고
    • Total ankle joint replacement
    • Stauffer R.N.: Total ankle joint replacement. Arch. Surg., 112: 1105–1109, 1977.
    • (1977) Arch. Surg. , vol.112 , pp. 1105-1109
    • Stauffer, R.N.1
  • 47
    • 0019415891 scopus 로고
    • Total ankle arthroplasty: four years' experience
    • Stauffer R.N. Segal N.M.: Total ankle arthroplasty: four years' experience. Clin. Orthop., 160: 217–221, 1981.
    • (1981) Clin. Orthop. , vol.160 , pp. 217-221
    • Stauffer, R.N.1    Segal, N.M.2
  • 48
    • 0005175046 scopus 로고
    • Springfield, IL Charles C Thomas
    • Steindler A.: Kinesiology. Springfield, IL, Charles C Thomas, 1961.
    • (1961) Kinesiology
    • Steindler, A.1
  • 49
    • 0019364909 scopus 로고
    • The deformation and wear of plastic components in artificial knee joints: an experimental study
    • Walker P.S. Ben-Dov M. Askew M.J. Pugh J.: The deformation and wear of plastic components in artificial knee joints: an experimental study. Eng. Med., 10: 33–38, 1981.
    • (1981) Eng. Med. , vol.10 , pp. 33-38
    • Walker, P.S.1    Ben-Dov, M.2    Askew, M.J.3    Pugh, J.4
  • 51
    • 0017462028 scopus 로고
    • Reactions of the articular capsule to wear products of artificial joint prostheses
    • Willert H.G.: Reactions of the articular capsule to wear products of artificial joint prostheses. J. Biomed. Mater. Res., 11: 157–164, 1977.
    • (1977) J. Biomed. Mater. Res. , vol.11 , pp. 157-164
    • Willert, H.G.1
  • 52
    • 0000331906 scopus 로고
    • Action of the subtalar and ankle joint complex during the stance phase of walking
    • Wright D.G. Desai S.M. Henderson W.H.: Action of the subtalar and ankle joint complex during the stance phase of walking. J. Bone Joint Surg., 46A: 361–382, 1964.
    • (1964) J. Bone Joint Surg. , vol.46A , pp. 361-382
    • Wright, D.G.1    Desai, S.M.2    Henderson, W.H.3
  • 53
    • 0022504260 scopus 로고
    • The problem of surface damage in polyethylene total knee components
    • Wright T.M. Bartel D.L.: The problem of surface damage in polyethylene total knee components. Clin. Orthop., 205: 67–74, 1986.
    • (1986) Clin. Orthop. , vol.205 , pp. 67-74
    • Wright, T.M.1    Bartel, D.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.