메뉴 건너뛰기




Volumn 35, Issue 9, 1988, Pages 758-763

Suppression of Simulation Artifacts from Myoelectric-Evoked Potential Recordings

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFACT; EVOKED RESPONSE; HEART MUSCLE POTENTIAL; METHODOLOGY; SIMULATION;

EID: 0023817890     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/10.7278     Document Type: Article
Times cited : (85)

References (12)
  • 2
  • 3
    • 0021890397 scopus 로고
    • A note on noninvasive estimation of muscle fiber conduction velocity
    • H. Broman, G. Bilotto and C. J. De Luca, “A note on noninvasive estimation of muscle fiber conduction velocity,” IEEE Trans. Biomed. Eng., vol. BME-32, pp. 341-344, 1985.
    • (1985) IEEE Trans. Biomed. Eng. , vol.BME-32 , pp. 341-344
    • Broman, H.1    Bilotto, G.2    De Luca, C.J.3
  • 4
    • 0017903812 scopus 로고
    • Hybrid stimulator for chronic experiments
    • F. Del Pozo and J. M. R. Delgado, “Hybrid stimulator for chronic experiments,” IEEE Trans. Biomed. Eng., vol. BME-25, pp. 92-94, 1978.
    • (1978) IEEE Trans. Biomed. Eng. , vol.BME-25 , pp. 92-94
    • Del Pozo, F.1    Delgado, J.M.R.2
  • 6
    • 0015105987 scopus 로고
    • An electronic stimulus artifact suppressor
    • J. A. Freeman, “An electronic stimulus artifact suppressor,” Electroencephalogr. clin. Neurophysiol., vol. 31, pp. 170-172, 1971.
    • (1971) Electroencephalogr. clin. Neurophysiol. , vol.31 , pp. 170-172
    • Freeman, J.A.1
  • 9
    • 0022995453 scopus 로고
    • Effect of electrode location on myoelectric conduction velocity and median frequency estimates
    • S. H. Roy, C. J. De Luca, and J. Schneider, “Effect of electrode location on myoelectric conduction velocity and median frequency estimates,” J. Appl. Physiol., BME-61, pp. 1510-1517, 1986.
    • (1986) J. Appl. Physiol. , vol.BME-61 , pp. 1510-1517
    • Roy, S.H.1    De Luca, C.J.2    Schneider, J.3
  • 10
    • 84939324059 scopus 로고
    • Microcomputer based electromyographic recording system with stimulus artifact suppression
    • Portoroz, Yugoslavia
    • E. Roskar and A. Roskar, “Microcomputer based electromyographic recording system with stimulus artifact suppression,” in Proc. III Mediterranean Conf. Biomed. Eng. Sec. 1.6, Portoroz, Yugoslavia, 1983.
    • (1983) Proc. III Mediterranean Conf. Biomed. Eng. Sec. 1.6
    • Roskar, E.1    Roskar, A.2
  • 11
    • 0021997652 scopus 로고
    • A technique for recording the EMG of electrically stimulated skeletal muscle
    • M. Solomonow, R. Baratta, T. Miwa, H. Shoji, and R. D'Ambrosia, “A technique for recording the EMG of electrically stimulated skeletal muscle,” Orthopedics. vol. 8, pp. 492-495, 1985.
    • (1985) Orthopedics , vol.8 , pp. 492-495
    • Solomonow, M.1    Baratta, R.2    Miwa, T.3    Shoji, H.4    D'Ambrosia, R.5
  • 12
    • 0022765174 scopus 로고
    • The myoelectric signal of electrically stimulated muscle during recruitment: An inherent feedback parameter for a closed loop control scheme
    • —, “The myoelectric signal of electrically stimulated muscle during recruitment: An inherent feedback parameter for a closed loop control scheme,” IEEE Trans. Biomed. Eng., vol. BME-33, pp. 735-745, 1986.
    • (1986) IEEE Trans. Biomed. Eng. , vol.BME-33 , pp. 735-745


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.