-
1
-
-
0020618677
-
Predicting count loss in modem positron emission tomography systems
-
Holmes TJ. Predicting count loss in modem positron emission tomography systems. IEEE Trans Nucl Sci 1983;NS-30:723-728
-
(1983)
IEEE Trans Nucl Sci
, vol.NS-30
, pp. 723-728
-
-
Holmes, T.J.1
-
2
-
-
0021915997
-
Dead time correction and counting statistics for positron tomography
-
Mazoyer BM, Roos MS, Huesman RH. Dead time correction and counting statistics for positron tomography. Phys Med Biol 1985;30:385-399
-
(1985)
Phys Med Biol
, vol.30
, pp. 385-399
-
-
Mazoyer, B.M.1
Roos, M.S.2
Huesman, R.H.3
-
3
-
-
0001189083
-
Positron emission tomography: Principles and quantitation
-
In: Phelps ME, Mazziotta JC, Schelbert HR, ed., New York: Raven Press
-
Hoffman EJ, Phelps ME. Positron emission tomography: Principles and quantitation. In: Phelps ME, Mazziotta JC, Schelbert HR, ed. Positron emission tomography and autoradiography. Principles and applications for the brain and heart. New York: Raven Press, 1986
-
(1986)
Positron Emission Tomography and Autoradiography. Principles and Applications for the Brain and Heart
-
-
Hoffman, E.J.1
Phelps, M.E.2
-
4
-
-
0022978151
-
Deadtime correction method using random coincidences for PET
-
Yamamoto S, Amano M, Miura S, Iida H, Kanno I. Deadtime correction method using random coincidences for PET. J Nucl Med 1986;27:1925-1928
-
(1986)
J Nucl Med
, vol.27
, pp. 1925-1928
-
-
Yamamoto, S.1
Amano, M.2
Miura, S.3
Iida, H.4
Kanno, I.5
-
5
-
-
0022669524
-
The effect of live time in components of a positron tomograph on image quantification
-
Thompson CJ, Meyer E. The effect of live time in components of a positron tomograph on image quantification. IEEE Trans Nucl Sci 1987;NS-34:337-343
-
(1987)
IEEE Trans Nucl Sci
, vol.NS-34
, pp. 337-343
-
-
Thompson, C.J.1
Meyer, E.2
-
7
-
-
0005494474
-
A real time digital coincidence processor for positron emission tomography
-
Dent HM, Jones WF, Casey ME. A real time digital coincidence processor for positron emission tomography. IEEE Trans Nucl Sci 1986;NS-33:556-559
-
(1986)
IEEE Trans Nucl Sci
, vol.NS-33
, pp. 556-559
-
-
Dent, H.M.1
Jones, W.F.2
Casey, M.E.3
-
8
-
-
2042453268
-
A VMEbus based, real time sorter design for positron emission tomography
-
Jones WF, Casey ME, Byars LG, Burgiss SG. A VMEbus based, real time sorter design for positron emission tomography. IEEE Trans Nucl Sci 1986;NS-33:601-604
-
(1986)
IEEE Trans Nucl Sci
, vol.NS-33
, pp. 601-604
-
-
Jones, W.F.1
Casey, M.E.2
Byars, L.G.3
Burgiss, S.G.4
-
9
-
-
0020703945
-
Performance figures and images from the therascan 3128 positron emission tomograph
-
Cooke BE, Evans AC, Fonthome EO, Alarie E, Sendyk AM. Performance figures and images from the therascan 3128 positron emission tomograph. IEEE Trans Nucl Sci 1984;NS-31:640-644
-
(1984)
IEEE Trans Nucl Sci
, vol.NS-31
, pp. 640-644
-
-
Cooke, B.E.1
Evans, A.C.2
Fonthome, E.O.3
Alarie, E.4
Sendyk, A.M.5
-
10
-
-
0021234438
-
Evaluation of the performance characteristics of the PC 4600 positron emission tomograph
-
Kearfott KJ, Carroll LR. Evaluation of the performance characteristics of the PC 4600 positron emission tomograph. J Comput Assist Tomogr 1984;8:502-513
-
(1984)
J Comput Assist Tomogr
, vol.8
, pp. 502-513
-
-
Kearfott, K.J.1
Carroll, L.R.2
-
11
-
-
0021332891
-
Performance study of the PC-384 positron camera system for emission tomography of the brain
-
Litton J, Bergstrom M, Eriksson L, Bohn C, Blomqvist G, Kesselberg M. Performance study of the PC-384 positron camera system for emission tomography of the brain. J Comput Assist Tomogr 1984;8:74-87
-
(1984)
J Comput Assist Tomogr
, vol.8
, pp. 74-87
-
-
Litton, J.1
Bergstrom, M.2
Eriksson, L.3
Bohn, C.4
Blomqvist, G.5
Kesselberg, M.6
-
12
-
-
0020962324
-
Performance evaluation of a positron tomograph designed for brain imaging
-
Hoffman EJ, Phelps ME, Huang SC. Performance evaluation of a positron tomograph designed for brain imaging J Nucl Med 1983;24:245-257
-
(1983)
J Nucl Med
, vol.24
, pp. 245-257
-
-
Hoffman, E.J.1
Phelps, M.E.2
Huang, S.C.3
-
15
-
-
0000671482
-
Dynamic, gated and high resolution imaging with the ECAT III
-
Hoffman EJ, Phelps ME, Huang SC, et al. Dynamic, gated and high resolution imaging with the ECAT III. IEEE Trans Nucl Sci 1986;NS-33:452-455
-
(1986)
IEEE Trans Nucl Sci
, vol.NS-33
, pp. 452-455
-
-
Hoffman, E.J.1
Phelps, M.E.2
Huang, S.C.3
-
17
-
-
84939045331
-
A multicrystal two dimensional BGO detector system for positron emission tomography
-
Casey ME, Nutt R: A multicrystal two dimensional BGO detector system for positron emission tomography. IEEE Trans Nucl Sci 1986;NS-33:460-463
-
(1986)
IEEE Trans Nucl Sci
, vol.NS-33
, pp. 460-463
-
-
Casey, M.E.1
Nutt, R.2
|