메뉴 건너뛰기




Volumn 94, Issue 3, 1987, Pages 367-374

Primary tissue failure in pericardial heart valves

Author keywords

[No Author keywords available]

Indexed keywords

CASE REPORT; DIAGNOSIS; FAILURE; FOLLOW UP; HEART; HUMAN; PRIORITY JOURNAL; THERAPY;

EID: 0023196661     PISSN: 00225223     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0022-5223(19)36249-x     Document Type: Article
Times cited : (74)

References (20)
  • 1
    • 0021683481 scopus 로고
    • Isolated mitral valve replacement with the Hancock bioprosthesis: a 13 year appraisal
    • Gallucci V Bortolotti U Milano A Valfré C Mazzucco A Thieme G Isolated mitral valve replacement with the Hancock bioprosthesis: a 13 year appraisal Ann Thorac Surg 38 1984 571 578
    • (1984) Ann Thorac Surg , vol.38 , pp. 571-578
    • Gallucci, V1    Bortolotti, U2    Milano, A3    Valfré, C4    Mazzucco, A5    Thieme, G6
  • 2
    • 84909888715 scopus 로고
    • Clinical durability of the pericardial xenograft valve: 11 years’ experience
    • Ionescu MI Tandon AM Saunders NR Chidambaram R Smith DR Clinical durability of the pericardial xenograft valve: 11 years’ experience Cohn LH Gallucci V Cardiac bioprostheses 1982 Yorke Medical Books New York 46 60
    • (1982) , pp. 46-60
    • Ionescu, MI1    Tandon, AM2    Saunders, NR3    Chidambaram, R4    Smith, DR5
  • 3
    • 0022382388 scopus 로고
    • In vitro hemodynamic comparison of porcine and pericardial valves
    • Cosgrove DM Lytle BW Gill CC In vitro hemodynamic comparison of porcine and pericardial valves J T horac C ardiovasc S urg 89 1985 358 368
    • (1985) J Thorac Cardiovasc Surg , vol.89 , pp. 358-368
    • Cosgrove, DM1    Lytle, BW2    Gill, CC3
  • 4
    • 0019164316 scopus 로고
    • Hemodynamic performance of the Ionescu-Shiley valve prosthesis
    • Becker RM Strom J Frishman W Hemodynamic performance of the Ionescu-Shiley valve prosthesis J T horac C ardiovasc S urg 80 1980 613 620
    • (1980) J Thorac Cardiovasc Surg , vol.80 , pp. 613-620
    • Becker, RM1    Strom, J2    Frishman, W3
  • 5
    • 0021125009 scopus 로고
    • New generation tissue valves: their in vitro function in the mitral position
    • Walker DK Scotten LN Brownlee RT New generation tissue valves: their in vitro function in the mitral position J T horac C ardiovasc S uro 88 1984 573 582
    • (1984) J Thorac Cardiovasc Suro , vol.88 , pp. 573-582
    • Walker, DK1    Scotten, LN2    Brownlee, RT3
  • 6
    • 0021053803 scopus 로고
    • Spontaneous disruption of the Ionecu-Shiley bovine pericardial xenograft in the mitral position
    • Gosh SC Larrieu AJ Ablaza SGG Grana VP Spontaneous disruption of the Ionecu-Shiley bovine pericardial xenograft in the mitral position J T horac C ardiovasc S urg 86 1983 784 790
    • (1983) J Thorac Cardiovasc Surg , vol.86 , pp. 784-790
    • Gosh, SC1    Larrieu, AJ2    Ablaza, SGG3    Grana, VP4
  • 7
    • 0020437326 scopus 로고
    • Sudden death due to cuspal dehiscence of the Ionescu-Shiley valve in the mitral position
    • Gabbay S Factor SM Strom J Becker R Frater RWM Sudden death due to cuspal dehiscence of the Ionescu-Shiley valve in the mitral position J T horac C ardiovasc S urg 84 1984 313 317
    • (1984) J Thorac Cardiovasc Surg , vol.84 , pp. 313-317
    • Gabbay, S1    Factor, SM2    Strom, J3    Becker, R4    Frater, RWM5
  • 9
    • 0021926349 scopus 로고
    • Ionescu-Shiley pericardial xenografts: follow-up of up to six years
    • Gabbay S Ionescu-Shiley pericardial xenografts: follow-up of up to six years Ann Thorac Surg 39 1985 101 102
    • (1985) Ann Thorac Surg , vol.39 , pp. 101-102
    • Gabbay, S1
  • 10
    • 0021925266 scopus 로고
    • Ionescu-Shiley pericardial xenografts: follow-up of up to six years
    • Brais MP Bedard JP Goldstein W Koshal A Keon WJ Ionescu-Shiley pericardial xenografts: follow-up of up to six years Ann Thorac Surg 39 1985 105 111
    • (1985) Ann Thorac Surg , vol.39 , pp. 105-111
    • Brais, MP1    Bedard, JP2    Goldstein, W3    Koshal, A4    Keon, WJ5
  • 12
    • 85112983467 scopus 로고    scopus 로고
    • 1
  • 15
    • 85056948035 scopus 로고
    • Design and stress analysis of bioprosthetic valves in vivo
    • Thubrikar MJ Skinner JR Nolan SP Design and stress analysis of bioprosthetic valves in vivo Cohn LH Gallucci V Cardiac bioprostheses 1982 Yorke Medical Books New York 445 455
    • (1982) , pp. 445-455
    • Thubrikar, MJ1    Skinner, JR2    Nolan, SP3
  • 16
    • 85113013295 scopus 로고    scopus 로고
    • Ionescu MI, Lenker JA, Rosenbluth RF. Low profile prosthetic xenograft heart valve. European Patent Application 813051224, 1981.
  • 17
    • 0022492149 scopus 로고
    • In vitro evaluation of six mechanical and six bioprosthetic valves
    • Fisher J Reece IJ Wheatley DJ In vitro evaluation of six mechanical and six bioprosthetic valves Thorac Cardiovasc Surg 34 1986 157 162
    • (1986) Thorac Cardiovasc Surg , vol.34 , pp. 157-162
    • Fisher, J1    Reece, IJ2    Wheatley, DJ3
  • 18
    • 0006103368 scopus 로고
    • Accelerated fatigue tests of heart valves: a preliminary database
    • Nugent AH Scotten N Walker DK Brownlee RT Accelerated fatigue tests of heart valves: a preliminary database Proc ACEMB 37 1984 149
    • (1984) Proc ACEMB , vol.37 , pp. 149
    • Nugent, AH1    Scotten, N2    Walker, DK3    Brownlee, RT4
  • 19
    • 0021714259 scopus 로고
    • Haemodynamics and durability of mitral bioprostheses: an in vitro study
    • Gabbay S Bortolotti U Wasserman F Factor S Haemodynamics and durability of mitral bioprostheses: an in vitro study Eur Heart J 5 Suppl D 1984 65 71
    • (1984) Eur Heart J , vol.5 , Issue.Suppl D , pp. 65-71
    • Gabbay, S1    Bortolotti, U2    Wasserman, F3    Factor, S4
  • 20
    • 9044239271 scopus 로고
    • Experience of four surgical centers with the Hancock pericardial valve
    • Bailly P Sauer M Vouhé P Experience of four surgical centers with the Hancock pericardial valve Bodnar E Yacoub M Biological and bioprosthetic valves 1986 Yorke Medical Books New York 744 748
    • (1986) , pp. 744-748
    • Bailly, P1    Sauer, M2    Vouhé, P3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.