메뉴 건너뛰기




Volumn 671, Issue , 1986, Pages 244-253

A technique to reject scattered radiation in pet transmission scans

Author keywords

[No Author keywords available]

Indexed keywords

ELECTROMAGNETIC WAVES - SCATTERING; GAMMA RAYS;

EID: 0023021257     PISSN: 0277786X     EISSN: 1996756X     Source Type: Conference Proceeding    
DOI: 10.1117/12.966702     Document Type: Conference Paper
Times cited : (26)

References (17)
  • 1
    • 0018455344 scopus 로고
    • The Donner 280-crystal High ResolutionPositron Tomograph
    • Derenzo, S. E., Greenberg, W., "The Donner 280-crystal High ResolutionPositron Tomograph, " IEEE Trans. Nucl. Sci. Vol. NS-26, pp. 2790-2793, 1979.
    • (1979) IEEE Trans. Nucl. Sci , vol.26 , pp. 2790-2793
    • Derenzo, S.E.1    Greenberg, W.2
  • 2
    • 0020072892 scopus 로고
    • A Positron Emission Tomograph Utilizing Cesium Fluoride Scintillation Detectors
    • Ter-Pogossian, M., Ficke, D. C., PETT VI: "A Positron Emission Tomograph Utilizing Cesium Fluoride Scintillation Detectors, " J. Comput. Assist. Tomogr., Vol. 6, pp. 125-133, 1982.
    • (1982) J. Comput. Assist. Tomogr. , vol.6 , pp. 125-133
    • Ter-Pogossian, M.1    Ficke, D.C.2    Pett, V.I.3
  • 3
    • 0018435637 scopus 로고
    • Correctionsfor Attenuation, Scattered Radiation, and Random Coincidences in a Ring Detector PositronEmission Transaxial Tomograph
    • Bergstrom, M., Bohm, C., Ericson, K., Eriksson, L. and Litton, J. "Correctionsfor Attenuation, Scattered Radiation, and Random Coincidences in a Ring Detector PositronEmission Transaxial Tomograph", IEEE Trans. Nucl. Sci. Vol. NS-27, pp. 549-554, 1980.
    • (1980) IEEE Trans. Nucl. Sci , pp. 549-554
    • Bergstrom, M.1    Bohm, C.2    Ericson, K.3    Eriksson, L.4    Litton, J.5
  • 4
    • 0020660172 scopus 로고
    • Correctionfor Scattered Radiation in a Ring Detector Positron Camera by Integral Transformation ofthe Projections
    • Bergstrom, M., Bohm, C., Ericson, K., Eriksson, L. and Litton, J., "Correctionfor Scattered Radiation in a Ring Detector Positron Camera by Integral Transformation ofthe Projections, " J. Comput. Assist. Tomgr., Vol. 7, pp. 42-50, 1983.
    • (1983) J. Comput. Assist. Tomgr. , vol.7 , pp. 42-50
    • Bergstrom, M.1    Bohm, C.2    Ericson, K.3    Eriksson, L.4    Litton, J.5
  • 5
    • 0020606181 scopus 로고
    • A Phantom to Assess Quantitative Recovery of Positron Tomographs
    • Cooke, B. E., Evans, A., "A Phantom to Assess Quantitative Recovery of Positron Tomographs, " J. Comput. Assist. Tomogr., Vol. 7, pp. 876-880, 1983.
    • (1983) J. Comput. Assist. Tomogr. , vol.7 , pp. 876-880
    • Cooke, B.E.1    Evans, A.2
  • 6
    • 0020911246 scopus 로고
    • A., "Performance Study of Single-Slice PositronEmission Tomography Scanners by Monte Carlo Techniques
    • Lupton, L. R., Keller, N. A., "Performance Study of Single-Slice PositronEmission Tomography Scanners by Monte Carlo Techniques, " IEEE Trans. Med. Imaging, Vol.MI-2, pp. 154-168, 1983.
    • (1983) IEEE Trans. Med. Imaging , pp. 154-168
    • Lupton, L.R.1    Keller, N.2
  • 8
    • 0021372398 scopus 로고
    • E., "Estimated Spect Count Densities, Scatter Fractions, and Statistical Noise
    • Jaszczack, R. J., Greer, K. L., Floyd Jr., C. E., Harris, C. G., Coleman, R. E., "Estimated Spect Count Densities, Scatter Fractions, and Statistical Noise, " IEEE Trans. Nucl. Sci., Vol. NS-32, pp. 762-768, 1985.
    • (1985) IEEE Trans. Nucl. Sci. , vol.32 , pp. 762-768
    • Jaszczack, R.J.1    Greer, K.L.2    Floyd, C.E.3    Harris, C.G.4    Coleman, R.5
  • 9
    • 0019402786 scopus 로고
    • A Boundary Method for Attenuation Correction in Positron Computed Tomography Scanner
    • Huang, S-C, Carson, R. E., Phelps, M. E. "A Boundary Method for Attenuation Correction in Positron Computed Tomography Scanner, " J. Nucl. Med., Vol. 22, pp. 627-637, 1981.
    • (1981) J. Nucl. Med. , vol.22 , pp. 627-637
    • Huang, S.-C.1    Carson, R.E.2    Phelps, M.E.3
  • 11
    • 0020703945 scopus 로고
    • Performance Figures and Images from theTherascan 3128 Positron Emission Tomograph
    • Cooke, B. E., Evans, A. C. "Performance Figures and Images from theTherascan 3128 Positron Emission Tomograph, " IEEE Trans. Nucl. Sci., Vol. NS-31, pp.640-644, 1984.
    • (1984) IEEE Trans. Nucl. Sci , pp. 640-644
    • Cooke, B.E.1    Evans, A.C.2
  • 14
    • 0012922027 scopus 로고    scopus 로고
    • The Orbiting Rod Source: Improving Performance in PET Transmission Correction Scans
    • Current Trends New York, Society of Nuclear Medicine
    • Carroll, L. R., Kretz, P. and Orcut, G. The Orbiting Rod Source: Improving Performance in PET Transmission Correction Scans. In: Emission Computed Tomography: Current Trends New York, Society of Nuclear Medicine, 1983.
    • Emission Computed Tomography , pp. 1983
    • Carroll, L.R.1    Kretz, P.2    Orcut, G.3
  • 15
    • 0021372397 scopus 로고
    • Real-time Data Rebinning in PET to Obtain Uniformly Sampled Projections
    • Dagher, A., Thompson, C. J. "Real-time Data Rebinning in PET to Obtain Uniformly Sampled Projections, " IEEE Trans. Nucl. Sci., Vol. NS-32, pp. 811-817, 1985.
    • (1985) IEEE Trans. Nucl. Sci , vol.32 , pp. 811-817
    • Dagher, A.1    Thompson, C.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.