메뉴 건너뛰기




Volumn 7, Issue 3, 1986, Pages 269-279

Quality assurance control in the EORTC cooperative group ofradiotherapy. 2. Dosimetric intercomparison 0131 0301V

Author keywords

Dosimetric intercomparison; Dosimetric uncertainty; Quality assurance control in radiotherapy

Indexed keywords

DOSIMETRY; METHODOLOGY; NONHUMAN; ORGANIZATION AND MANAGEMENT; PRIORITY JOURNAL; QUALITY CONTROL; RADIOTHERAPY; THERAPY;

EID: 0022892847     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(86)80038-X     Document Type: Article
Times cited : (71)

References (25)
  • 1
    • 0008817736 scopus 로고
    • Physical aspects of quality assurance in radiation therapy
    • (1984) Report
  • 3
    • 0020004114 scopus 로고
    • The recombination correction for an ionization chamber exposed to pulsed radiation in a “swept beam” technique
    • (1982) I Theory. Phys. Med. Biol. , vol.27 , pp. 201-211
    • Boag1
  • 5
    • 84912615954 scopus 로고    scopus 로고
    • CIPM (Comité International des Poids et Mesures) Assignment of experimental uncertainties. Recommendation 1 (CI-1981).
  • 10
    • 0015349875 scopus 로고
    • A review of the activities of the AAPM radiological physics center in interinstitutional trials involving radiation therapy
    • (1972) Cancer , vol.29 , pp. 1468-1472
    • Golden1    Cundiff2    Grant3    Shalek4
  • 11
    • 0022922671 scopus 로고    scopus 로고
    • Gonzalez van der Schueren EVan den Bogaert W and Notter G Quality assurance control in the EORTC cooperative group of radiotherapy I Assessment of radiotherapy staff and equipment
    • Horiot J.C., Johansson K.-A., Gonzalez, van der Schueren E.,Van den Bogaert W. and Notter G. Quality assurance control in the EORTC cooperative group of radiotherapy. I. Assessment of radiotherapy staff and equipment. Radiother Oncol. 6: 275–284.
    • Radiotherapy and Oncology , vol.6 , pp. 275-284
    • Horiot1    Johansson2
  • 12
    • 0021921688 scopus 로고
    • Temperature-presure compensation for a linear accelerator electron beam dosimeter
    • (1985) Med. Phys. , vol.12 , pp. 260-261
    • Hrejsa1    Soen2    Jankowiak3
  • 13
    • 0003464633 scopus 로고
    • Radiation Dosimetry: X-ray and gamma rays with maximum photon energies between 0.6 and 50 MeV
    • International Commission on Radiation Units and Measurements, Washington D.C., U.S.A.
    • (1969) ICRU Report 14
  • 15
    • 0003639048 scopus 로고
    • Radiation Dosimetry: Electron beams with energies between 1 and 50 MeV
    • International Commission on Radiation Units and Measurements, Bethesda, MD, U.S.A.
    • (1984) ICRU Report 35
  • 17
    • 0004069084 scopus 로고
    • Studies of different methods of absorbed dose determination and a dosimetric intercomparison at the Nordic Radiotherapy Centres
    • (1982) Thesis, Göteborg, Sweden
    • Johansson1
  • 20
    • 0022374945 scopus 로고
    • Comparison of different protocols for the dosimetry of high-energy photon and electron beams
    • (1985) Radiother. Oncol. , vol.4 , pp. 313-318
    • Mattsson1
  • 21
    • 84907111892 scopus 로고
    • Procedures in external radiation therapy dosimetry with electron and photon beams with maximum energies between 1 and 50 MeV
    • (1980) Acta Oncologica , vol.19 , pp. 55-79
  • 22
    • 0019839017 scopus 로고
    • Electron beams with mean energies at the phantom surface below 15 MeV
    • (1981) Acta Radiol. Oncol. , vol.20 , pp. 402-415
  • 23
    • 0020819767 scopus 로고
    • Variation of output with atmospheric pressure and ambient temperature for Therac-20 linear accelerator
    • (1983) Med. Phys. , vol.10 , pp. 712
    • Sharma1    Wilson2    Jose3
  • 25
    • 0022084895 scopus 로고
    • Determination of ionization chamber collection efficiency in a swept electron beam by means of thermoluminescent detectors and the “two-voltage” method. Radiother
    • (1985) Oncol. , vol.3 , pp. 363-370
    • Van Dam1    Rijnders2    Ang3    Mellaerts4    Grobet5