메뉴 건너뛰기




Volumn BME-31, Issue 2, 1984, Pages 177-186

System Optimization for Improved Accuracy in Transcutaneous Signal and Power Transmission

Author keywords

[No Author keywords available]

Indexed keywords

HUMAN; NONBIOLOGICAL MODEL; POWER MEASUREMENT; SIGNAL; SKIN;

EID: 0021285916     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.1984.325404     Document Type: Article
Times cited : (115)

References (22)
  • 1
    • 0000547648 scopus 로고
    • High-level electromagnetic energy transfer through a closed chest-wall
    • J. C. Schuder, H. E. Stephenson, and J. F. Townsend, “High-level electromagnetic energy transfer through a closed chest-wall,” in IRE Int. Conv. Rec., pt. 9, vol. 9, pp. 119–126, 1961.
    • (1961) IRE Int. Conv. Rec. , vol.9 , pp. 119-126
    • Schuder, J.C.1    Stephenson, H.E.2    Townsend, J.F.3
  • 2
    • 0017559930 scopus 로고
    • Design of rf-powered coils for implant instruments
    • W. H. Ko, S. P. Liang, and C.D.F. Fung, “Design of rf-powered coils for implant instruments,” Med. Biol. Eng. Comput., vol. 15, pp. 634–640, 1977.
    • (1977) Med. Biol. Eng. Comput. , vol.15 , pp. 634-640
    • Ko, W.H.1    Liang, S.P.2    Fung, C.D.F.3
  • 3
    • 0015029903 scopus 로고
    • Mutual inductance of air-cored coils: effect on design of rf-coupled implants
    • F. C. Flack, E. D. James, and D. M. Schlapp, “Mutual inductance of air-cored coils: effect on design of rf-coupled implants,” Med. Biol. Eng., vol. 9, pp. 79–85, 1971.
    • (1971) Med. Biol. Eng. , vol.9 , pp. 79-85
    • Flack, F.C.1    James, E.D.2    Schlapp, D.M.3
  • 4
    • 27744587681 scopus 로고
    • Apparatus for efficient power transfer through a tissue barrier
    • J. W. Fuller, “Apparatus for efficient power transfer through a tissue barrier,” IEEE Trans. Biomed. Eng., vol. BME-16, no. 1, pp. 63–65, 1968.
    • (1968) IEEE Trans. Biomed. Eng. , vol.BME-16 , Issue.1 , pp. 63-65
    • Fuller, J.W.1
  • 5
    • 0015083432 scopus 로고
    • An inductively coupled rf system for the transmission of 1 kW of power through the skin
    • J. C. Schuder, J. H. Gold, and H. E. Stephenson, Jr., “An inductively coupled rf system for the transmission of 1 kW of power through the skin,” IEEE Trans. Biomed. Eng., vol. BME-18, no. 5, 1971.
    • (1971) IEEE Trans. Biomed. Eng. , vol.BME-18 , Issue.5
    • Schuder, J.C.1    Gold, J.H.2    Stephenson, H.E.3
  • 6
    • 0014533490 scopus 로고
    • Energizing implantable transmitters by means of coupled inductance coils
    • R. Kadefors, E. Kaiser, and I. Petersen, “Energizing implantable transmitters by means of coupled inductance coils,” IEEE Trans. Biomed. Eng., vol. BME-16, no. 3, pp. 177–183, 1969.
    • (1969) IEEE Trans. Biomed. Eng. , vol.BME-16 , Issue.3 , pp. 177-183
    • Kadefors, R.1    Kaiser, E.2    Petersen, I.3
  • 7
    • 0017101850 scopus 로고
    • Controlled external powering of miniaturized chronically implanted biotelemetry devices
    • R. Kadefors, “Controlled external powering of miniaturized chronically implanted biotelemetry devices,” IEEE Trans. Biomed. Eng., vol. BME-23, no. 2, pp. 124–129, 1976.
    • (1976) IEEE Trans. Biomed. Eng. , vol.BME-23 , Issue.2 , pp. 124-129
    • Kadefors, R.1
  • 8
    • 0018331038 scopus 로고
    • Single frequency rf powered ECG telemetry system
    • W. H. Ko, J. Hynecek, and J. Homa, “Single frequency rf powered ECG telemetry system,” IEEE Trans. Biomed. Eng., vol. BME-26, no. 2, pp. 105–109, 1979.
    • (1979) IEEE Trans. Biomed. Eng. , vol.BME-26 , Issue.2 , pp. 105-109
    • Ko, W.H.1    Hynecek, J.2    Homa, J.3
  • 9
    • 0020332056 scopus 로고
    • A transcutaneous implanted battery recharging and biotelemeter power switching system
    • D. C. Jeutter, “A transcutaneous implanted battery recharging and biotelemeter power switching system,” IEEE Trans. Biomed. Eng., vol. BME-29, no. 5, pp. 314–321, 1982.
    • (1982) IEEE Trans. Biomed. Eng. , vol.BME-29 , Issue.5 , pp. 314-321
    • Jeutter, D.C.1
  • 10
    • 0014340444 scopus 로고
    • The skin tunnel transformer; A new system that permits both high efficiency transfer of power and telemetry of data through the intact skin
    • C. F. Andren, M. A. Fadali, V. L. Gott, and S. R. Topaz, “The skin tunnel transformer; A new system that permits both high efficiency transfer of power and telemetry of data through the intact skin,” IEEE Trans. Biomed. Eng., vol. BME-15, no. 4, pp. 278–285, 1968.
    • (1968) IEEE Trans. Biomed. Eng. , vol.BME-15 , Issue.4 , pp. 278-285
    • Andren, C.F.1    Fadali, M.A.2    Gott, V.L.3    Topaz, S.R.4
  • 11
    • 0019547573 scopus 로고
    • An implanted auditory eight-channel stimulator for the deaf
    • Mar.
    • E. S. Hochmair and I. J. Hochmair-Desoyer, “An implanted auditory eight-channel stimulator for the deaf,” Med. Biol. Eng. Comput., vol. 19, pp. 141–148, Mar. 1981.
    • (1981) Med. Biol. Eng. Comput. , vol.19 , pp. 141-148
    • Hochmair, E.S.1    Hochmair-Desoyer, I.J.2
  • 13
    • 54949152106 scopus 로고
    • Electrical properties of tissue and cell suspensions
    • H. Schwan, “Electrical properties of tissue and cell suspensions,” Advan. Biol. Med. Phys., no. 5, p. 147, 1957.
    • (1957) Advan. Biol. Med. Phys. , vol.5 , pp. 147
    • Schwan, H.1
  • 17
    • 33749723365 scopus 로고
    • Berechnung der Gegeninduktivität achsenparalleler Zylinderspulen
    • L. Hannakam, “Berechnung der Gegeninduktivität achsenparalleler Zylinderspulen,” Archiv für Elektrotechnik, vol. 51, no. 3, pp. 141–154, 1967.
    • (1967) Archiv für Elektrotechnik , vol.51 , Issue.3 , pp. 141-154
    • Hannakam, L.1
  • 20
    • 0018748367 scopus 로고
    • Comments on energy flux along high voltage transmission lines
    • Y. J. Seto and J. A. Cronvich, “Comments on energy flux along high voltage transmission lines,” IEEE Trans. Biomed. Eng., vol. BME-26, no. 3, pp. 182–183, 1979.
    • (1979) IEEE Trans. Biomed. Eng. , vol.BME-26 , Issue.3 , pp. 182-183
    • Seto, Y.J.1    Cronvich, J.A.2
  • 21
    • 0015953648 scopus 로고
    • Therapeutic applications of electromagnetic power
    • A. N. Guy, J. F. Lehmann, and J. B. Stonebridge, “Therapeutic applications of electromagnetic power,” Proc. IEEE, vol. 62, no. 1, pp. 55–75, 1974.
    • (1974) Proc. IEEE , vol.62 , Issue.1 , pp. 55-75
    • Guy, A.N.1    Lehmann, J.F.2    Stonebridge, J.B.3
  • 22
    • 0020645014 scopus 로고
    • Percepts elicited by different speech coding strategies
    • E. S. Hochmair and I. J. Hochmair-Desoyer, “Percepts elicited by different speech coding strategies,” in Ann. NY Acad. Sci., vol. 405, pp. 268–279, 1983.
    • (1983) Ann. NY Acad. Sci. , vol.405 , pp. 268-279
    • Hochmair, E.S.1    Hochmair-Desoyer, I.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.