메뉴 건너뛰기




Volumn 7, Issue 1, 1983, Pages 42-50

Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections

Author keywords

Data processing; Emission computed tomography; Scatter

Indexed keywords

RADIOISOTOPE;

EID: 0020660172     PISSN: 03638715     EISSN: 15323145     Source Type: Journal    
DOI: 10.1097/00004728-198302000-00008     Document Type: Article
Times cited : (296)

References (19)
  • 2
    • 0018103086 scopus 로고
    • ECAT: A new computerized tomographic imaging system for positron- emitting radiopharmaceuticals
    • Phelps ME, Hoffman EJ, Huang S-C, Kuhl DE: ECAT: A new computerized tomographic imaging system for positron- emitting radiopharmaceuticals. J Nucl Med 1978:19:635-47.
    • (1978) J Nucl Med , vol.19 , pp. 635-647
    • Phelps, M.E.1    Hoffman, E.J.2    Huang, S.-C.3    Kuhl, D.E.4
  • 4
    • 0018367149 scopus 로고
    • Quantitation in posi-tron emission computed tomography: 1. Effect of object size
    • Hoffman EJ, Huang S-C, Phelps ME: Quantitation in posi-tron emission computed tomography: 1. Effect of object size. J Comput Assist Tomogr 1979;3:299-308.
    • (1979) J Comput Assist Tomogr , vol.3 , pp. 299-308
    • Hoffman, E.J.1    Huang, S.-C.2    Phelps, M.E.3
  • 5
    • 0018667264 scopus 로고
    • Quantitation in positron emission computed tomography: 2. Effects of inaccurate attenuation correction
    • Huang S-C, Hoffman EJ, Phelps ME, Kuhl DE. Quantitation in positron emission computed tomography: 2. Effects of inaccurate attenuation correction. J Comput Assisi Tomogr 1979:3:804-14.
    • (1979) J Comput Assisi Tomogr , vol.3 , pp. 804-814
    • Huang, S.-C.1    Hoffman, E.J.2    Phelps, M.E.3    Kuhl, D.E.4
  • 6
    • 0018435637 scopus 로고
    • Corrections for attenuation, scattered radiation and random coincidences in a ring detector positron emission transaxial tomograph
    • Bergström M, Bohm C, Ericson K, Eriksson L, Litton J. Corrections for attenuation, scattered radiation and random coincidences in a ring detector positron emission transaxial tomograph. IEEE Trans Nncl Sei 1980;NS-27:549-54.
    • (1980) IEEE Trans Nncl Sei , vol.27 , pp. 549-554
    • Bergström, M.1    Bohm, C.2    Ericson, K.3    Eriksson, L.4    Litton, J.5
  • 8
    • 0018939380 scopus 로고
    • Method for optimizing side shielding in positron-emission tomographs and for comparing detector materials
    • Derenzo SE. Method for optimizing side shielding in positron-emission tomographs and for comparing detector materials. J Nncl Med 1980:21:971-6.
    • (1980) J Nncl Med , vol.21 , pp. 971-976
    • Derenzo, S.E.1
  • 11
    • 0019524035 scopus 로고
    • Quantifica-tion in positron emission computed tomography: 4. Effect of accidental coincidences
    • Hoffman EJ, Huang SC, Phelps ME, Kuhl DE. Quantifica-tion in positron emission computed tomography: 4. Effect of accidental coincidences. J Comput Assisi Tumour 1981;5:391-400.
    • (1981) J Comput Assisi Tumour , vol.5 , pp. 391-400
    • Hoffman, E.J.1    Huang, S.C.2    Phelps, M.E.3    Kuhl, D.E.4
  • 13
    • 0019450411 scopus 로고
    • HEADTOME: A hybrid emission tomograph for single photon and positron emission imaging of the brain
    • Kanno I, Uemura K, Miura S, Miura Y. HEADTOME: A hybrid emission tomograph for single photon and positron emission imaging of the brain. J Comput Assisi Tomoffr 1981;5:216-26.
    • (1981) J Comput Assisi Tomoffr , vol.5 , pp. 216-226
    • Kanno, I.1    Uemura, K.2    Miura, S.3    Miura, Y.4
  • 14
    • 0018983329 scopus 로고
    • Noise identi-fication and removal in positron imaging systems
    • King PH, Hubner K, Gibbs W, Holloway E. Noise identi-fication and removal in positron imaging systems. IEEE Trans Nncl Sci 1981;NS-28:1:148-151.
    • (1981) IEEE Trans Nncl Sci , vol.28 , Issue.1 , pp. 148-151
    • King, P.H.1    Hubner, K.2    Gibbs, W.3    Holloway, E.4
  • 15
    • 0019525266 scopus 로고
    • A procedure for calibrating and correcting data to achieve accurate quantitative values in positron emission tomography
    • Bergstrom M, Eriksson L, Bohm C, Blomqvist G, Greitz T, Litton J, and Widen L. A procedure for calibrating and correcting data to achieve accurate quantitative values in positron emission tomography. IEEE Trans Nncl Sci 1982;NS-29:555-7.
    • (1982) IEEE Trans Nncl Sci , vol.29 , pp. 555-557
    • Bergstrom, M.1    Eriksson, L.2    Bohm, C.3    Blomqvist, G.4    Greitz, T.5    Litton, J.6    Widen, L.7
  • 16
    • 0020048935 scopus 로고
    • Determination of object contour from projections for attenuation correction in cranial positron emission tomography
    • Bergstrom M, Litton J, Eriksson L, Bohm C, Blomqvist G. Determination of object contour from projections for attenuation correction in cranial positron emission tomography. J Compttt Assist Tomogr 1982:6:365-72.
    • (1982) J Compttt Assist Tomogr , vol.6 , pp. 365-372
    • Bergstrom, M.1    Litton, J.2    Eriksson, L.3    Bohm, C.4    Blomqvist, G.5
  • 17
    • 0019525267 scopus 로고
    • Performance study of PETT VI. A positron computed tomograph with 288 cesium fluoride detectors
    • Yamamoto Y, Ficke DC, Ter-Pogossian MM. Performance study of PETT VI. a positron computed tomograph with 288 cesium fluoride detectors. IEEE Trans Nucl Sci 1982;NS- 29:529-33.
    • (1982) IEEE Trans Nucl Sci , vol.29 , pp. 529-533
    • Yamamoto, Y.1    Ficke, D.C.2    Ter-Pogossian, M.M.3
  • 18
    • 0019525907 scopus 로고
    • A four ring posi-tron camera system for emission tomography of the brain
    • Eriksson L, Bohm C, Kesselberg M et al. A four ring posi-tron camera system for emission tomography of the brain. IEEE Trans Nucl Sci 1982;NS-29:539-43.
    • (1982) IEEE Trans Nucl Sci , vol.29 , pp. 539-543
    • Eriksson, L.1    Bohm, C.2    Kesselberg, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.