메뉴 건너뛰기




Volumn 29, Issue 6, 1982, Pages 370-376

Sensitivity Considerations for PVDF Hydrophones Using the Spot-Poled Membrane Design

Author keywords

[No Author keywords available]

Indexed keywords

HYDROPHONES;

EID: 0020330145     PISSN: 00189537     EISSN: None     Source Type: Journal    
DOI: 10.1109/T-SU.1982.31369     Document Type: Article
Times cited : (33)

References (18)
  • 1
    • 0019682057 scopus 로고
    • Piezoelectricity in polyvinylidenefluoride
    • G. M. Sessler, “Piezoelectricity in polyvinylidenefluoride,” J. Acoust. Soc. Amer., vol. 70, pp. 1596-1608, 1981.
    • (1981) J. Acoust. Soc. Amer. , vol.70 , pp. 1596-1608
    • Sessler, G.M.1
  • 2
    • 33750101326 scopus 로고
    • Polymeric ultrasonic probe
    • “Piezoelectric polymer probe for ultrasonic applications,” J. Acoust. Soc. Amer., 69, pp. 853-859, 1981
    • A. S. DeReggi, S. C. Roth, J. M. Kenney, S. Edelman, and G. R. Harris, “Polymeric ultrasonic probe,” J. Acoust. Soc. Amer., Suppl. 1, vol. 64, pp. S55-S56, 1978; “Piezoelectric polymer probe for ultrasonic applications,” J. Acoust. Soc. Amer., vol. 69, pp. 853-859, 1981.
    • (1978) J. Acoust. Soc. Amer. , vol.64 , pp. S55-S56
    • DeReggi, A.S.1    Roth, S.C.2    Kenney, J.M.3    Edelman, S.4    Harris, G.R.5
  • 3
    • 0019610662 scopus 로고
    • Miniature piezoelectric polymer ultrasonic hydrophone probes
    • P. A. Lewin, “Miniature piezoelectric polymer ultrasonic hydrophone probes,” Ultrasonics, vol. 19, pp. 213-216, 1981.
    • (1981) Ultrasonics , vol.19 , pp. 213-216
    • Lewin, P.A.1
  • 4
    • 0019925765 scopus 로고
    • Characteristics of a pvdf membrane hydrophone for use in the range 1-100 MHz
    • D.R. Bacon, “Characteristics of a pvdf membrane hydrophone for use in the range 1-100 MHz,” IEEE Trans. Sonics Ultrason., vol. SU-29, pp. 18-25, 1982.
    • (1982) IEEE Trans. Sonics Ultrason. , vol.SU-29 , pp. 18-25
    • Bacon, D.R.1
  • 7
    • 0017546195 scopus 로고
    • The suitability of polyvinylidene fluoride as an underwater transducer material
    • B. Woodward, “The suitability of polyvinylidene fluoride as an underwater transducer material,” Acustica, vol. 38, pp. 264-268, 1977.
    • (1977) Acustica , vol.38 , pp. 264-268
    • Woodward, B.1
  • 9
    • 0017535075 scopus 로고
    • Study of acoustic wave resonance in piezoelectric PVF2 film
    • L. N. Bui, H. J. Shaw, and L. T. Zitelli, “Study of acoustic wave resonance in piezoelectric PVF2 film,” IEEE Trans. Sonics Ultrason., vol. SU-24, pp. 331-336, 1977.
    • (1977) IEEE Trans. Sonics Ultrason. , vol.SU-24 , pp. 331-336
    • Bui, L.N.1    Shaw, H.J.2    Zitelli, L.T.3
  • 10
    • 84967454056 scopus 로고
    • Practical problems with piezoelectric hydrophone probes in medical ultrasonics
    • A.P.J.B. Walton, “Practical problems with piezoelectric hydrophone probes in medical ultrasonics,” Ultrasonics, vol. 15, pp. 148-149, 1977.
    • (1977) Ultrasonics , vol.15 , pp. 148-149
    • Walton, A.P.J.B.1
  • 12
    • 0000563423 scopus 로고
    • Acoustic Fields and Waves in Solids
    • New York: John Wiley and Sons ch. 8
    • B. A. Auld, Acoustic Fields and Waves in Solids, vol. I. New York: John Wiley and Sons, 1973, ch. 8.
    • (1973) , vol.1
    • Auld, B.A.1
  • 13
    • 0019021395 scopus 로고
    • A pvdf membrane hydrophone for operation in the range 0.5 MHz to 15 MHz
    • K. C. Shotton, D. R. Bacon, and R. M. Quilliam, “A pvdf membrane hydrophone for operation in the range 0.5 MHz to 15 MHz,” Ultrasonics, vol. 18, pp. 123-126, 1980.
    • (1980) Ultrasonics , vol.18 , pp. 123-126
    • Shotton, K.C.1    Bacon, D.R.2    Quilliam, R.M.3
  • 14
    • 0020203548 scopus 로고
    • Calibration of miniature ultrasonic receivers using a planar scanning technique
    • B. A. Herman and G. R. Harris, “Calibration of miniature ultrasonic receivers using a planar scanning technique,” J. Acoust. Soc. Amer., vol. 72, pp. 1357-1363, 1982.
    • (1982) J. Acoust. Soc. Amer. , vol.72 , pp. 1357-1363
    • Herman, B.A.1    Harris, G.R.2
  • 16
    • 84929617554 scopus 로고    scopus 로고
    • AIUM/NEMA Standards Publ. No. UL1-1981, National Electrical Manufacturers Association, Washington, DC 20037
    • Safety Standard for Diagnostic Ultrasound Equipment, AIUM/NEMA Standards Publ. No. UL1-1981, National Electrical Manufacturers Association, Washington, DC 20037.
    • Safety Standard for Diagnostic Ultrasound Equipment


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.