메뉴 건너뛰기




Volumn 1, Issue 3, 1982, Pages 192-196

An Improved Algorithm for Reprojecting Rays Through Pixel Images

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL ENGINEERING - COMPUTERIZED TOMOGRAPHY; IMAGE PROCESSING - RECONSTRUCTION;

EID: 0020204372     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/TMI.1982.4307572     Document Type: Article
Times cited : (284)

References (26)
  • 2
    • 0016068344 scopus 로고
    • Three dimensional reconstruction in nuclear medicine imaging
    • T. F. Budinger and G. T. Golberg, “Three dimensional reconstruction in nuclear medicine imaging,” IEEE Trans. Nucl. Sci., vol. NS-21, pp. 2-20, 1974.
    • (1974) IEEE Trans. Nucl. Sci , vol.NS-21 , pp. 2-20
    • Budinger, T.F.1    Golberg, G.T.2
  • 3
    • 0017395779 scopus 로고
    • The effects of a finite number of projection angles and finite lateral sampling of projections on the propagation of statistical errors in transverse section reconstruction
    • R. H. Huesman, “The effects of a finite number of projection angles and finite lateral sampling of projections on the propagation of statistical errors in transverse section reconstruction,” Phys. Med. Biol., vol. 22, pp. 511-521, 1977.
    • (1977) Phys. Med. Biol , vol.22 , pp. 511-521
    • Huesman, R.H.1
  • 5
    • 0013600035 scopus 로고
    • Three dimensional density reconstruction from a series of two-dimensional projections
    • M. Goitein, “Three dimensional density reconstruction from a series of two-dimensional projections,” Nucl. Inst. Methods, vol. 101, pp. 509-518, 1972.
    • (1972) Nucl. Inst. Methods , vol.101 , pp. 509-518
    • Goitein, M.1
  • 6
    • 0017810277 scopus 로고
    • A method for correcting bone induced artifacts in computed tomography scanners
    • P. M. Joseph and R. D. Spital, “A method for correcting bone induced artifacts in computed tomography scanners,” J. Comput. Assist. Tomogr., vol. 2, pp. 100-108, 1978.
    • (1978) J. Comput. Assist. Tomogr. , vol.2 , pp. 100-108
    • Joseph, P.M.1    Spital, R.D.2
  • 7
    • 0017802122 scopus 로고
    • Standardization of computed tomography images by means of a material selective beam hardening correction
    • P. Ruegsegger, T. Hangartner, H. U. Keller, and Th. Hinderling, “Standardization of computed tomography images by means of a material selective beam hardening correction,” J. Comput. Assist. Tomogr., vol. 2, pp. 184-188, 1978.
    • (1978) J. Comput. Assist. Tomogr. , vol.2 , pp. 184-188
    • Ruegsegger, P.1    Hangartner, T.2    Keller, H.U.3    Hinderling, T.4
  • 8
    • 0018074758 scopus 로고
    • Corrections for beam hardening in computed tomography
    • P. K. Kijewski and B. E. Bjarngard, “Corrections for beam hardening in computed tomography,” Med. Phys., vol. 5, pp. 209-214, 1978.
    • (1978) Med. Phys , vol.5 , pp. 209-214
    • Kijewski, P.K.1    Bjarngard, B.E.2
  • 9
    • 0018404829 scopus 로고
    • Post reconstruction method for beam hardening in computerized tomography
    • O. Nalcioglu and R.-S. Y. Lou, “Post reconstruction method for beam hardening in computerized tomography,” Phys. Med. Biol., vol. 24, pp. 330-340, 1979.
    • (1979) Phys. Med. Biol , vol.24 , pp. 330-340
    • Nalcioglu, O.1    Lou, R.-S.Y.2
  • 10
    • 0019528381 scopus 로고
    • Towards imaging the beating heart usefully with a conventional CT scanner
    • G. C. Mackinnon and R. H. T. Bates, “Towards imaging the beating heart usefully with a conventional CT scanner,” IEEE Trans. Biomed. Eng., vol. BME-28, pp. 123-127, 1981.
    • (1981) IEEE Trans. Biomed. Eng , vol.BME-28 , pp. 123-127
    • Mackinnon, G.C.1    Bates, R.H.T.2
  • 11
    • 84937995392 scopus 로고
    • Experimental simulation evaluation of EKG-gated heart scans with a small number of views
    • P. M. Joseph, “Experimental simulation evaluation of EKG-gated heart scans with a small number of views,” Invest. Radiol., vol. 17, p. S-8, 1982.
    • (1982) Invest. Radiol , vol.17 , pp. S-8
    • Joseph, P.M.1
  • 12
    • 84938021951 scopus 로고
    • The application of maximum entropy and Bayesian optimization methods to image reconstruction from projections
    • Univ. Pennsylvania, Philadelphia, PA, Tech. Rep. 73, Dec
    • G. T. Herman, “The application of maximum entropy and Bayesian optimization methods to image reconstruction from projections,” Medical Image Processing Group Dep. Radiology, Univ. Pennsylvania, Philadelphia, PA, Tech. Rep. 73, p. 17, Dec. 1982.
    • (1982) Medical Image Processing Group Dep. Radiology , pp. 17
    • Herman, G.T.1
  • 13
    • 0019606589 scopus 로고
    • Algorithms for fast back- and reprojection in computed tomography
    • T. M. Peters, “Algorithms for fast back- and reprojection in computed tomography,” IEEE Trans. Nucl. Sci., vol. NS-28, pp. 3641-3647, 1981.
    • (1981) IEEE Trans. Nucl. Sci , vol.NS-28 , pp. 3641-3647
    • Peters, T.M.1
  • 14
    • 0018354459 scopus 로고
    • A simulation study of aliasing in computed tomography
    • C. D. Stockham, “A simulation study of aliasing in computed tomography,” Radiol., vol. 132, pp. 721-726, 1979.
    • (1979) Radiol , vol.132 , pp. 721-726
    • Stockham, C.D.1
  • 16
    • 0016068330 scopus 로고
    • The Fourier reconstruction of a head section
    • L. A. Shepp and B. F. Logan, “The Fourier reconstruction of a head section,” IEEE Trans. Nucl. Sci., vol. NS-21, pp. 21-43, 1974.
    • (1974) IEEE Trans. Nucl. Sci , vol.NS-21 , pp. 21-43
    • Shepp, L.A.1    Logan, B.F.2
  • 17
    • 0017991568 scopus 로고
    • Image noise and smoothing in computed tomography
    • P. M. Joseph, “Image noise and smoothing in computed tomography,” Optical Eng., vol. 17, pp. 396-399, 1978.
    • (1978) Optical Eng , vol.17 , pp. 396-399
    • Joseph, P.M.1
  • 18
    • 0019035182 scopus 로고
    • The effects of sampling on CT images
    • P. M. Joseph, R. D. Spital, and C. D. Stockham, “The effects of sampling on CT images,” Comput. Tomogr., vol. 4, pp. 189-206, 1980.
    • (1980) Comput. Tomogr , vol.4 , pp. 189-206
    • Joseph, P.M.1    Spital, R.D.2    Stockham, C.D.3
  • 20
    • 0018677282 scopus 로고
    • Aliasing artifacts in computerized tomography
    • C. R. Crawford and A. C. Kak, “Aliasing artifacts in computerized tomography,” Appl. Optics, vol. 18, pp. 3704-3711, 1979.
    • (1979) Appl. Optics , vol.18 , pp. 3704-3711
    • Crawford, C.R.1    Kak, A.C.2
  • 21
    • 0019031639 scopus 로고
    • The influence of Gantry geometry on aliasing and other geometry dependent errors
    • P. M. Joseph, “The influence of Gantry geometry on aliasing and other geometry dependent errors,” IEEE Trans. Nucl. Sci., vol. NS-27, pp. 1104-1111, 1980.
    • (1980) IEEE Trans. Nucl. Sci , vol.NS-27 , pp. 1104-1111
    • Joseph, P.M.1
  • 22
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • L. A. Shepp and Y. Vardi, “Maximum likelihood reconstruction for emission tomography,” IEEE Trans. Med. Imaging, vol. MI-1, pp. 113-122, 1982.
    • (1982) IEEE Trans. Med. Imaging , vol.MI-1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 23
    • 0003907340 scopus 로고
    • A method and apparatus for examination of a body by radiation such as X or gamma radiation
    • Patent Specification 1283915, Patent Office, London, England
    • G. N. Hounsfield, “A method and apparatus for examination of a body by radiation such as X or gamma radiation,” Patent Specification 1283915, Patent Office, London, England, 1972.
    • (1972)
    • Hounsfield, G.N.1
  • 24
    • 0037580182 scopus 로고
    • Computerized tomography: The new medical X-ray technology
    • L. A. Shepp and J. B. Kruskal, “Computerized tomography: The new medical X-ray technology,” Amer. Math. Monthly, vol. 85, pp. 420-439, 1978.
    • (1978) Amer. Math. Monthly , vol.85 , pp. 420-439
    • Shepp, L.A.1    Kruskal, J.B.2
  • 25
    • 0019460905 scopus 로고
    • The exponential edge-gradient effect in X-ray computed tomography
    • P. M. Joseph and R. D. Spital, “The exponential edge-gradient effect in X-ray computed tomography,” Phys. Med. Biol., vol. 26, pp. 473-487, 1981.
    • (1981) Phys. Med. Biol , vol.26 , pp. 473-487
    • Joseph, P.M.1    Spital, R.D.2
  • 26
    • 0020194244 scopus 로고
    • Collimator effects in high resolution X-ray computed tomography
    • J. G. Verly, “Collimator effects in high resolution X-ray computed tomography,” IEEE Trans. Med. Imaging, vol. MM, pp. 122-136, 1982.
    • (1982) IEEE Trans. Med. Imaging , vol.MM , pp. 122-136
    • Verly, J.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.