Volumn 36, Issue 8, 1981, Pages 401-417

Complete and partial uterine perforation and embedding following insertion of intrauterine devices. II. Diagnostic methods, prevention, and management

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL RADIOGRAPHY; DIAGNOSIS; DRUG THERAPY; FEMALE GENITAL SYSTEM; HYSTEROGRAPHY; INTRAUTERINE CONTRACEPTIVE DEVICE; PNEUMOGRAPHY; PREVENTION; RADIOLOGY; REVIEW; THERAPY; UTERUS PERFORATION;

EID: 0019725969     PISSN: 00297828     EISSN: 15339866     Source Type: Journal    
DOI: 10.1097/00006254-198108000-00001     Document Type: Article
Times cited : (62)

References (152)
  • 1
    • 84932401711 scopus 로고
    • American College of Obstetricians and Gynecologists Technical Bulletin 40: The intrauterine device
    • Chicago, Illinois, June
    • Adel, S. K., Ghoneim, M. A., and Sobrero, A. J. American College of Obstetricians and Gynecologists Technical Bulletin 40: The intrauterine device. The American College of Obstetricians and Gynecologist, Chicago, Illinois, June, 1976.
    • (1976) The American College of Obstetricians and Gynecologist
    • Adel, S.K.1    Ghoneim, M.A.2    Sobrero, A.J.3
  • 2
    • 0015134097 scopus 로고
    • Hyster-ographic study of log-term effects of intrauterine contraceptive devices
    • Adel, S. K., Ghoneim, M. A., and Sobrero, A. J.: Hyster-ographic study of log-term effects of intrauterine contraceptive devices. Fertil. Steril. 22: 651, 1971.
    • (1971) Fertil. Steril , vol.22 , pp. 651
    • Adel, S.K.1    Ghoneim, M.A.2    Sobrero, A.J.3
  • 3
    • 0014823772 scopus 로고
    • Uterine perforation by Lippes loop
    • Alberts, P. S., and Alberts, B. I.: Uterine perforation by Lippes loop. Obstet. Gynecol. 36: 164, 1970.
    • (1970) Obstet. Gynecol , vol.36 , pp. 164
    • Alberts, P.S.1    Alberts, B.I.2
  • 4
    • 0015385805 scopus 로고
    • Removal of intrauterine contraceptive devices after uterine perforation
    • Allen, J. R., Shemwell, R. E., Macleod, D. O., et al.: Removal of intrauterine contraceptive devices after uterine perforation. Obstet. Gynecol. 40: 225, 1972.
    • (1972) Obstet. Gynecol , vol.40 , pp. 225
    • Allen, J.R.1    Shemwell, R.E.2    Macleod, D.O.3
  • 5
    • 0014140521 scopus 로고
    • Uterine perforation by an intrauterine contraceptive device
    • Andrews, J. W. H., and Gavourin, B. A.: Uterine perforation by an intrauterine contraceptive device. Med. Serv. J. Can. 23: 1111, 1967.
    • (1967) Med. Serv. J. Can , vol.23 , pp. 1111
    • Andrews, J.1    Gavourin, B.A.2
  • 6
    • 84930781628 scopus 로고
    • Missing strings
    • Ansari, A. H.: Missing strings. Obstet. Gynecol. 46: 501, 1975.
    • (1975) Obstet. Gynecol , vol.46 , pp. 501
    • Ansari, A.H.1
  • 7
    • 84932412866 scopus 로고
    • Perforation of the large bowel by a Daikon shield intrauterine device
    • Athary, T. A., and Pizzaro, C.: Perforation of the large bowel by a Daikon shield intrauterine device. J. Reprod. Med. 17: 311, 1976.
    • (1976) J. Reprod. Med , vol.17 , pp. 311
    • Athary, T.A.1    Pizzaro, C.2
  • 8
    • 85039307386 scopus 로고
    • Perforation of uterus by intrauterine devices
    • Babenerd, J., and Metz, K. O.: Perforation of uterus by intrauterine devices. Munch. Med. Wochenschr. 12: 855, 1979.
    • (1979) Munch. Med. Wochenschr , vol.12 , pp. 855
    • Babenerd, J.1    Metz, K.O.2
  • 9
    • 0018367824 scopus 로고
    • Contact hysteroscopy: A new technique to explore the uterine cavity
    • Baggish, M. S.: Contact hysteroscopy: A new technique to explore the uterine cavity. Obstet. Gynecol. 54: 350, 1979.
    • (1979) Obstet. Gynecol , vol.54 , pp. 350
    • Baggish, M.S.1
  • 10
    • 0018866375 scopus 로고
    • Contact hysteroscopy: Another method of endoscopic examination of the uterine cavity
    • Barbot, J., Parent, B., and Dubuisson, J. B.: Contact hysteroscopy: Another method of endoscopic examination of the uterine cavity. Am. J. Obstet. Gynecol. 136: 721, 1980.
    • (1980) Am. J. Obstet. Gynecol , vol.136 , pp. 721
    • Barbot, J.1    Parent, B.2    Dubuisson, J.B.3
  • 12
    • 0017668299 scopus 로고
    • Perforation of the uterus as a complication of intrauterine contraception with Gra-vigard
    • Birch, C. D., and Jensen, S. K.: Perforation of the uterus as a complication of intrauterine contraception with Gra-vigard. Ugeskr. Laeger 139: 1907, 1977.
    • (1977) Ugeskr. Laeger , vol.139 , pp. 1907
    • Birch, C.D.1    Jensen, S.K.2
  • 13
    • 0017309050 scopus 로고
    • Translocation of the intrauterine contraceptive device
    • Borkotoky, R. U., and Mampilli, K. J. C.: Translocation of the intrauterine contraceptive device. J. Indian Med. Assoc. 67: 147, 1976.
    • (1976) J. Indian Med. Assoc , vol.67 , pp. 147
    • Borkotoky, R.U.1    Mampilli, K.2
  • 14
    • 0015333369 scopus 로고
    • Removal of intra-abdominal intrauterine contraceptive devices through a peritoneoscope with the use of intraoperative fluoroscopy to aid localization
    • Brooks, P. G., Berci, G., Laurence, A., Slipyan, P., et al.: Removal of intra-abdominal intrauterine contraceptive devices through a peritoneoscope with the use of intraoperative fluoroscopy to aid localization. Am. J. Obstet. Gynecol. 113: 104, 1972.
    • (1972) Am. J. Obstet. Gynecol , vol.113 , pp. 104
    • Brooks, P.G.1    Berci, G.2    Laurence, A.3    Slipyan, P.4
  • 15
    • 0014082230 scopus 로고
    • Uterine perforation with intrauterine contraceptive devices
    • Burnhill, M. S., and Birnberg, C. H.: Uterine perforation with intrauterine contraceptive devices. Am. J. Obstet. Gynecol. 98: 135, 1967.
    • (1967) Am. J. Obstet. Gynecol , vol.98 , pp. 135
    • Burnhill, M.S.1    Birnberg, C.H.2
  • 16
    • 0017839171 scopus 로고
    • The fragmented intrauterine device: An unusual complication of Lippes loop
    • Burray, K. A., and Pernoll, M. L.: The fragmented intrauterine device: An unusual complication of Lippes loop. Fertil. Steril. 29: 218, 1978.
    • (1978) Fertil. Steril , vol.29 , pp. 218
    • Burray, K.A.1    Pernoll, M.L.2
  • 17
    • 0016401799 scopus 로고
    • Translocation of intrauterine contraceptive devices
    • Cederqvist, L. L., and Birnbaum, S. J.: Translocation of intrauterine contraceptive devices. Lancet 1: 1057, 1974.
    • (1974) Lancet , vol.1 , pp. 1057
    • Cederqvist, L.L.1    Birnbaum, S.J.2
  • 18
    • 0016737725 scopus 로고
    • Perforation of the uterus by the Copper-T and Copper-7 intrauterine contraceptive devices
    • Cederqvist, L. L., Lindhe, B.-A., and Fuchs, F.: Perforation of the uterus by the Copper-T and Copper-7 intrauterine contraceptive devices. Acta Obstet. Gynecol. Scand. 54: 183, 1975.
    • (1975) Acta Obstet. Gynecol. Scand , vol.54 , pp. 183
    • Cederqvist, L.L.1    Lindhe, B.-A.2    Fuchs, F.3
  • 19
    • 0016789775 scopus 로고
    • Translocation of the Daikon shield into the broad ligament
    • Cederqvist, L. L., Saary, I. I., and Zervoudakis, I. A.: Translocation of the Daikon shield into the broad ligament. Obstet. Gynecol. 46: 239, 1975.
    • (1975) Obstet. Gynecol , vol.46 , pp. 239
    • Cederqvist, L.L.1    Saary, I.I.2    Zervoudakis, I.A.3
  • 20
    • 0015100504 scopus 로고
    • Intrauterine contraceptive device: A review and case report of perforation
    • Chafi, J.: Intrauterine contraceptive device: A review and case report of perforation. J. Maine Med. Assoc. 61: 179, 1971.
    • (1971) J. Maine Med. Assoc , vol.61 , pp. 179
    • Chafi, J.1
  • 22
    • 0015047162 scopus 로고
    • Intra-abdominal Lippes loop removed at laparoscopy
    • Cibils, L. A., and Moragne, R.: Intra-abdominal Lippes loop removed at laparoscopy. J. Reprod. Med. 6: 194, 1971.
    • (1971) J. Reprod. Med , vol.6 , pp. 194
    • Cibils, L.A.1    Moragne, R.2
  • 23
    • 84932414107 scopus 로고
    • The value of ultrasound in the management of intrauterine devices
    • edited by Sanders, R. C., and James, A. E., Appleton-Century-Croft, New York
    • Cochrane, W. J.: The value of ultrasound in the management of intrauterine devices. InUltrasonography in Obstetrics and Gynecologyedited by Sanders, R. C., and James, A. E., Appleton-Century-Croft, New York, 1977, pp 394-5, 398
    • (1977) Ultrasonography in Obstetrics and Gynecology
    • Cochrane, W.J.1
  • 24
    • 0015398870 scopus 로고
    • The use of ultrasound B-mode scanning with localization of intrauterine contraceptive devices
    • Cochrane, W. J., and Thomas, M. A.: The use of ultrasound B-mode scanning with localization of intrauterine contraceptive devices. Radiology 104: 623, 1972.
    • (1972) Radiology , vol.104 , pp. 623
    • Cochrane, W.J.1    Thomas, M.A.2
  • 25
    • 0017764588 scopus 로고
    • Bowel obstruction and perforation with an intraperitoneal loop intrauterine contraceptive device
    • D Amico, J., and Israel, R.: Bowel obstruction and perforation with an intraperitoneal loop intrauterine contraceptive device. Am. J. Obstet. Gynecol. 129: 461, 1977.
    • (1977) Am. J. Obstet. Gynecol , vol.129 , pp. 461
    • D Amico, J.1    Israel, R.2
  • 26
    • 0018216864 scopus 로고
    • Radiologic techniques tor localization of intrauterine devices
    • Dana, A., Tubiana, J. M., Rozier, J. Y., et al.: Radiologic techniques tor localization of intrauterine devices. Ann Radiol (Paris) 21: 601, 1978.
    • (1978) Ann Radiol (Paris) , vol.21 , pp. 601
    • Dana, A.1    Tubiana, J.M.2    Rozier, J.Y.3
  • 28
    • 0014558388 scopus 로고
    • Uterine perforation with the Lippes loop: Detection by hysterography
    • Dhall, K., Dhall, G. I., and Gupta, B. B.: Uterine perforation with the Lippes loop: Detection by hysterography. Obstet. Gynecol. 34: 266, 1969.
    • (1969) Obstet. Gynecol , vol.34 , pp. 266
    • Dhall, K.1    Dhall, G.I.2    Gupta, B.B.3
  • 29
    • 0016371843 scopus 로고
    • Intrauterine device extraction: A safe method utilizing fluoroscopy
    • Diaconis, J. N., and Weiner, C. I.: Intrauterine device extraction: A safe method utilizing fluoroscopy. Radiology 111: 479, 1974.
    • (1974) Radiology , vol.111 , pp. 479
    • Diaconis, J.N.1    Weiner, C.I.2
  • 30
    • 17544398795 scopus 로고
    • Ultrasound localization of intrauterine contraceptive devices
    • Domstad, P. A.: Ultrasound localization of intrauterine contraceptive devices. J. Tenn. Med. Assoc. 70: 334, 1977.
    • (1977) J. Tenn. Med. Assoc , vol.70 , pp. 334
    • Domstad, P.A.1
  • 31
    • 0015052713 scopus 로고
    • Intraperitoneal contraceptive device: Removal via colpotomy
    • Dudley, A. G., and Fischer, C.: Intraperitoneal contraceptive device: Removal via colpotomy. Milit. Med. 136: 488, 1971.
    • (1971) Milit. Med , vol.136 , pp. 488
    • Dudley, A.G.1    Fischer, C.2
  • 34
    • 0015691822 scopus 로고
    • A Daikon shield imbedded in a myoma: Case report of an unusual displacement of an intrauterine device
    • Esposito, J. M., Zarou, D. M., and Zarou, G. S.: A Daikon shield imbedded in a myoma: Case report of an unusual displacement of an intrauterine device. Am. J. Obstet. Gynecol. 117: 578, 1973.
    • (1973) Am. J. Obstet. Gynecol , vol.117 , pp. 578
    • Esposito, J.M.1    Zarou, D.M.2    Zarou, G.S.3
  • 35
    • 0014811275 scopus 로고
    • Removal of the Lippes loop through the laparoscope
    • Faroqui, M. O., and Shannon, R. H.: Removal of the Lippes loop through the laparoscope. Practitioner 205: 65, 1970.
    • (1970) Practitioner , vol.205 , pp. 65
    • Faroqui, M.O.1    Shannon, R.H.2
  • 36
    • 84973585552 scopus 로고
    • Laparoscopic removal of lUDs from the abdomen
    • Fell, M. R.: Laparoscopic removal of lUDs from the abdomen. Br. Med. J. 1: 1343, 1976.
    • (1976) Br. Med. J , vol.1 , pp. 1343
    • Fell, M.R.1
  • 37
    • 0017213803 scopus 로고
    • Extrauterine IUD and pregnancy. Spontaneous labor. Extraction of IUD by laparoscopy
    • Galan, G., Gayan, P., Corbalan, G., et al.: Extrauterine IUD and pregnancy. Spontaneous labor. Extraction of IUD by laparoscopy. Rev. Chil. Obstet. Ginecol. 41: 237, 1976.
    • (1976) Rev. Chil. Obstet. Ginecol , vol.41 , pp. 237
    • Galan, G.1    Gayan, P.2    Corbalan, G.3
  • 38
    • 0017484874 scopus 로고
    • Removal of an extrauterine IUD by combined laparoscopy and colpotomy
    • Gawecki, F. M., and Ludwin, G. A.: Removal of an extrauterine IUD by combined laparoscopy and colpotomy. Nebr. Med. J. 62:99, 1977.
    • (1977) Nebr. Med. J , vol.62 , pp. 99
    • Gawecki, F.M.1    Ludwin, G.A.2
  • 40
    • 0017483607 scopus 로고
    • Perforation of the uterus by Lippes loop
    • Gerlock, A. J.: Perforation of the uterus by Lippes loop. J. Tenn. Med. Assoc. 70: 256, 1977.
    • (1977) J. Tenn. Med. Assoc , vol.70 , pp. 256
    • Gerlock, A.J.1
  • 41
    • 0015325849 scopus 로고
    • Perforation of the uterus by intrauterine device
    • Graff, G., and Sharf, M.: Perforation of the uterus by intrauterine device. Int. Surg. 57: 340, 1972.
    • (1972) Int. Surg , vol.57 , pp. 340
    • Graff, G.1    Sharf, M.2
  • 42
    • 0017652561 scopus 로고
    • Translocation of the intrauterine contraceptive device: Study of thirty-one cases
    • Guha-Ray, D. K.: Translocation of the intrauterine contraceptive device: Study of thirty-one cases. Fertil. Steril. 28: 943, 1977.
    • (1977) Fertil. Steril , vol.28 , pp. 943
    • Guha-Ray, D.K.1
  • 43
    • 0015887816 scopus 로고
    • Conversion of Lippes loop into a closed loop: A potential hazard of translocation
    • Gunaratne, M., and Mahroof, H. M.: Conversion of Lippes loop into a closed loop: A potential hazard of translocation. Contraception 8: 357, 1973.
    • (1973) Contraception , vol.8 , pp. 357
    • Gunaratne, M.1    Mahroof, H.M.2
  • 44
    • 0017761247 scopus 로고
    • Hysteroscopic removal of intrauterine contraceptive devices with missing threads
    • Gupta, I., Devi, P. K., and Gupta, A. N.: Hysteroscopic removal of intrauterine contraceptive devices with missing threads. Indian J. Med. Res. 65: 661, 1977.
    • (1977) Indian J. Med. Res , vol.65 , pp. 661
    • Gupta, I.1    Devi, P.K.2    Gupta, A.N.3
  • 45
    • 0017280978 scopus 로고
    • Double uterine perforation with Daikon shield intrauterine device
    • Hakim-Elahi, E.: Double uterine perforation with Daikon shield intrauterine device. N. Y. State J. Med. 76: 567, 1976.
    • (1976) N. Y. State J. Med , vol.76 , pp. 567
    • Hakim-Elahi, E.1
  • 46
    • 0014207343 scopus 로고
    • A reappraisal of intrauterine contraceptive devices: Prompted by the delayed discovery of uterine perforations
    • Hall, R. E.: A reappraisal of intrauterine contraceptive devices: Prompted by the delayed discovery of uterine perforations. Am. J. Obstet. Gynecol. 99: 808, 1967.
    • (1967) Am. J. Obstet. Gynecol , vol.99 , pp. 808
    • Hall, R.E.1
  • 49
    • 0015969933 scopus 로고
    • Differential uterine measurements recorded in vivo
    • Hasson, H. M.: Differential uterine measurements recorded in vivo. Obstet. Gynecol. 43: 400, 1974.
    • (1974) Obstet. Gynecol , vol.43 , pp. 400
    • Hasson, H.M.1
  • 50
    • 0018177150 scopus 로고
    • Factors that affect IUD performance: A review and recommendations
    • Hasson, H. M.: Factors that affect IUD performance: A review and recommendations. J. Reprod. Med. 21: 137, 1978.
    • (1978) J. Reprod. Med , vol.21 , pp. 137
    • Hasson, H.M.1
  • 51
    • 84915109584 scopus 로고
    • Perforation of the uterine wall by the Lippes loop in postpartum women
    • edited by Hefnawi, F., and Segal, S. J. American Elsevier Company, Inc., New York
    • Hefnawi, F., Hosni, M., El-Sheikha, Z., et al.: Perforation of the uterine wall by the Lippes loop in postpartum women. InAnalysis of Intrauterine Contraception, edited by Hefnawi, F., and Segal, S. J. American Elsevier Company, Inc., New York, 1975, pp 469-476.
    • (1975) Analysis of Intrauterine Contraception , pp. 469-476
    • Hefnawi, F.1    Hosni, M.2    El-Sheikha, Z.3
  • 52
    • 0017655562 scopus 로고
    • The problem of the lost intrauterine contraceptive device
    • Hepp, H.: The problem of the lost intrauterine contraceptive device. Geburtshilfe Frauenheilkd 37: 653, 1977.
    • (1977) Geburtshilfe Frauenheilkd , vol.37 , pp. 653
    • Hepp, H.1
  • 53
    • 84935797424 scopus 로고
    • Laparoscopic removal of lUDsfrom the abdomen
    • Herrara-Llerandi, R.: Laparoscopic removal of lUDsfrom the abdomen. Br. Med. J. 2: 590, 1976.
    • (1976) Br. Med. J , vol.2 , pp. 590
    • Herrara-Llerandi, R.1
  • 54
    • 0014833187 scopus 로고
    • The intrauterine contraceptive device and uterine perforation
    • Hodes, H. C.: The intrauterine contraceptive device and uterine perforation. J. Kans. Med. Soc. 71: 318, 1970.
    • (1970) J. Kans. Med. Soc , vol.71 , pp. 318
    • Hodes, H.C.1
  • 57
    • 0015394073 scopus 로고
    • Ultrasonic localization of the Lippes loop. Obstet
    • lanniruberto, A., and Mastroberardino, A.: Ultrasonic localization of the Lippes loop. Obstet. Gynecol. 114: 78, 1972.
    • (1972) Gynecol , vol.114 , pp. 78
    • Lanniruberto, A.1    Mastroberardino, A.2
  • 58
    • 0015369602 scopus 로고
    • Laparoscopic removal of ectopically lodged intrauterine devices
    • Irvin, L. A., Neal, R. M., Wilkening, R. L., et al.: Laparoscopic removal of ectopically lodged intrauterine devices. Calif. Med. 117: 62, 1972.
    • (1972) Calif. Med , vol.117 , pp. 62
    • Irvin, L.A.1    Neal, R.M.2    Wilkening, R.L.3
  • 59
    • 0017755423 scopus 로고
    • Translocated intrauterine contraceptive devices and missing strings
    • Ismail, R. A.: Translocated intrauterine contraceptive devices and missing strings. S. Afr. Med. J. 52: 233, 1977.
    • (1977) S. Afr. Med. J , vol.52 , pp. 233
    • Ismail, R.A.1
  • 60
    • 84932408347 scopus 로고
    • Removal of extrauterine intrauterine devices
    • edited by Phillips, J. M. Williams & Wilkins Company, Baltimore
    • Israel, R.: Removal of extrauterine intrauterine devices. In Laparoscopy, edited by Phillips, J. M. Williams & Wilkins Company, Baltimore, 1977, pp 140-144.
    • (1977) Laparoscopy , pp. 140-144
    • Israel, R.1
  • 61
    • 0015759558 scopus 로고
    • Ultrasonic detection, localization and identification of interuterine contraceptive devices
    • Janssens, D., Vrigens, M., Thiery, M., et al.: Ultrasonic detection, localization and identification of interuterine contraceptive devices. Contraception 8: 485, 1973.
    • (1973) Contraception , vol.8 , pp. 485
    • Janssens, D.1    Vrigens, M.2    Thiery, M.3
  • 62
    • 84932410235 scopus 로고
    • Editorial comment
    • on Millen, A., Austin, F., and Bernstein, G. S.: Analysis of 100 cases of missing IUD strings. Contraception 18: 485, 1978
    • Jones, H. W., Jr.: Editorial comment (on Millen, A., Austin, F., and Bernstein, G. S.: Analysis of 100 cases of missing IUD strings. Contraception 18: 485, 1978). In Obstet. Gynecol. Surv. 34: 399, 1979.
    • (1979) Obstet. Gynecol. Surv , vol.34 , pp. 399
    • Jones, H.W.1
  • 63
    • 0016608806 scopus 로고
    • Location of the missing intrauterine contraceptive device
    • Jouppila, P.: Location of the missing intrauterine contraceptive device. Acta Obstet. Gynecol. Scand. 54: 71, 1975.
    • (1975) Acta Obstet. Gynecol. Scand , vol.54 , pp. 71
    • Jouppila, P.1
  • 64
    • 0014780537 scopus 로고
    • Hysteropneu-mopelvigraphy in chronic presence of intrauterine contraceptive devices: A new method of investigating complicated cases: Fertil
    • Kamal, I., Hefnawi, S., Ghoneim, M., et al.: Hysteropneu-mopelvigraphy in chronic presence of intrauterine contraceptive devices: A new method of investigating complicated cases: Fertil. Steril. 31: 402, 1970.
    • (1970) Steril , vol.31 , pp. 402
    • Kamal, I.1    Hefnawi, S.2    Ghoneim, M.3
  • 65
    • 0018865042 scopus 로고
    • Gastrointestinal complications of modern intrauterine devices
    • Key, T. C., and Kreutner, A. K.: Gastrointestinal complications of modern intrauterine devices. Obstet. Gynecol. 55: 239, 1980.
    • (1980) Obstet. Gynecol , vol.55 , pp. 239
    • Key, T.C.1    Kreutner, A.K.2
  • 66
    • 0016828172 scopus 로고
    • Large bowel perforation by intrauterine contraceptive devices
    • Kirkpatrick, D., Schneider, J., and Petersen, E. P.: Large bowel perforation by intrauterine contraceptive devices. Obstet. Gynecol. 465: 610, 1975.
    • (1975) Obstet. Gynecol , vol.465 , pp. 610
    • Kirkpatrick, D.1    Schneider, J.2    Petersen, E.P.3
  • 67
    • 0005177164 scopus 로고
    • Laparoscopic removal of a perforated Copper-T IUD: A case report
    • Koetsawang, S.: Laparoscopic removal of a perforated Copper-T IUD: A case report. Contraception 7: 327, 1973.
    • (1973) Contraception , vol.7 , pp. 327
    • Koetsawang, S.1
  • 68
    • 0015423474 scopus 로고
    • Laparoscopic removal of ectopic intrauterine devices
    • Kozloff, S. R., Engel, T., Bernstein, D., et al.: Laparoscopic removal of ectopic intrauterine devices. Rocky Mt. Med. J. 69: 41, 1972.
    • (1972) Rocky Mt. Med. J , vol.69 , pp. 41
    • Kozloff, S.R.1    Engel, T.2    Bernstein, D.3
  • 69
    • 85039307117 scopus 로고
    • Possibilities of ultrasonic diagnosis in localization of lUDs
    • Laszlo, T.: Possibilities of ultrasonic diagnosis in localization of lUDs. Orv. Hetil. 118: 138, 1977.
    • (1977) Orv. Hetil , vol.118 , pp. 138
    • Laszlo, T.1
  • 70
    • 0014002940 scopus 로고
    • Intrauterine contraceptive devices: The recognition and management of uterine perforations
    • Ledger, W. J., and Willson, J. R.: Intrauterine contraceptive devices: The recognition and management of uterine perforations. Obstet. Gynecol. 28: 806, 1966.
    • (1966) Obstet. Gynecol , vol.28 , pp. 806
    • Ledger, W.J.1    Willson, J.R.2
  • 71
    • 84970809923 scopus 로고
    • Removal of extrauterine Saf-T-Coil through laparoscope
    • Ledward, R. S.. Healey. C., and Eadie, R.: Removal of extrauterine Saf-T-Coil through laparoscope Br. Med. J. 1: 508, 1972.
    • (1972) Br. Med. J , vol.1 , pp. 508
    • Ledward, R.S.1    Healey, C.2    Eadie, R.3
  • 72
    • 0014482802 scopus 로고
    • Uterine perforation and intrauterine devices
    • Lefebvre, Y., Moutquin, J.-M., Lamquin, R., et al.: Uterine perforation and intrauterine devices. Union. Med Can. 98: 432, 1969.
    • (1969) Union. Med Can , vol.98 , pp. 432
    • Lefebvre, Y.1    Moutquin, J.-M.2    Lamquin, R.3
  • 73
    • 0013785709 scopus 로고
    • X-ray appearance of intrauterine contraceptive devices
    • Lehfeldt, H.: X-ray appearance of intrauterine contraceptive devices. Fertil. Steril. 16: 502, 1965.
    • (1965) Fertil. Steril , vol.16 , pp. 502
    • Lehfeldt, H.1
  • 74
    • 0015193226 scopus 로고
    • X-ray diagnosis of transposition of intrauterine devices
    • Lemus, M., Arancibia, G., and Banodos, G.: X-ray diagnosis of transposition of intrauterine devices. Rev. Chil. Obstet. Ginecol. 36: 270, 1971.
    • (1971) Rev. Chil. Obstet. Ginecol , vol.36 , pp. 270
    • Lemus, M.1    Arancibia, G.2    Banodos, G.3
  • 75
    • 0015127198 scopus 로고
    • Laparoscopic removal of intrauterine contraceptive devices following uterine perforation
    • Leventhal, J. M., Simon, L. R., and Shapiro, S. S.: Laparoscopic removal of intrauterine contraceptive devices following uterine perforation. Am. J. Obstet. Gynecol. 111: 102, 1971.
    • (1971) Am. J. Obstet. Gynecol , vol.111 , pp. 102
    • Leventhal, J.M.1    Simon, L.R.2    Shapiro, S.S.3
  • 76
    • 0015783828 scopus 로고
    • Laparoscopic removal of perforated lUDs
    • Levinson, C. J.: Laparoscopic removal of perforated lUDs. J. Reprod. Med. 10: 169, 1973.
    • (1973) J. Reprod. Med , vol.10 , pp. 169
    • Levinson, C.J.1
  • 77
    • 0014675310 scopus 로고
    • Uterine perforation following insertion of the loop
    • Liao, S. C., Lee, C. H., and Chow, L. P.: Uterine perforation following insertion of the loop Am. J. Obstet Gynecol. 103: 224, 1979.
    • (1979) Am. J. Obstet Gynecol , vol.103 , pp. 224
    • Liao, S.C.1    Lee, C.H.2    Chow, L.P.3
  • 78
    • 0017662845 scopus 로고
    • Perforation of the uterus by Copper-IUDs
    • Liedholm, P., and Ästedt, B.: Perforation of the uterus by Copper-IUDs. Int. J. Gynaecol. Obstet. 14: 557, 1976.
    • (1976) Int. J. Gynaecol. Obstet , vol.14 , pp. 557
    • Liedholm, P.1    Ästedt, B.2
  • 79
    • 0017301150 scopus 로고
    • IUD-related hospitalization and mortality
    • Lippes, J.: IUD-related hospitalization and mortality. J.A.M.A. 235: 1001, 1976.
    • (1976) J.A.M.A , vol.235 , pp. 1001
    • Lippes, J.1
  • 80
    • 84909526892 scopus 로고
    • Management of the lost IUD: A conservative approach
    • edited by Sciarra, J. J., Zatuchni, G. I., Spiedel, J. Harper and Row, Hagerstown, Maryland
    • Lippes, J.: Management of the lost IUD: A conservative approach. InRisks, Benefits and Controversies in Fertility Control, edited by Sciarra, J. J., Zatuchni, G. I., Spiedel, J. Harper and Row, Hagerstown, Maryland, 1978, pp 404-407.
    • (1978) Risks, Benefits and Controversies in Fertility Control , pp. 404-407
    • Lippes, J.1
  • 81
    • 0014015127 scopus 로고
    • Perforation of the postpartum uterus with an intrauterine contraceptive device
    • MacFarlan, S. M.: Perforation of the postpartum uterus with an intrauterine contraceptive device. Am. J. Obstet. Gynecol. 94: 283, 1966.
    • (1966) Am. J. Obstet. Gynecol , vol.94 , pp. 283
    • Macfarlan, S.M.1
  • 82
    • 0016165807 scopus 로고
    • Translocation of intrauterine contraceptive devices
    • MacKay, D. H. W., and Mowat, J.: Translocation of intrauterine contraceptive devices. Lancet 1: 652, 1974.
    • (1974) Lancet , vol.1 , pp. 652
    • Mackay, D.1    Mowat, J.2
  • 83
    • 0017835549 scopus 로고
    • Ultrasonic localization of missing intrauterine contraceptive devices
    • McArdle, C. R.: Ultrasonic localization of missing intrauterine contraceptive devices. Obstet. Gynecol. 51: 330, 1978.
    • (1978) Obstet. Gynecol , vol.51 , pp. 330
    • McArdle, C.R.1
  • 84
    • 0015774064 scopus 로고
    • Silent uterine perforation with Lippes loop and its management
    • Mahran, M., Karim, M., and El Maghoub, S.: Silent uterine perforation with Lippes loop and its management. Int. Surg. 58: 341, 1973.
    • (1973) Int. Surg , vol.58 , pp. 341
    • Mahran, M.1    Karim, M.2    El Maghoub, S.3
  • 85
    • 0014086460 scopus 로고
    • A simple technic of hysterography for evaluating side effects and mode of action of intrauterine devices
    • Mahzer, K., Kamal, I., Hefnani, F., et al.: A simple technic of hysterography for evaluating side effects and mode of action of intrauterine devices. Fertil. Steril. 18: 353, 1968.
    • (1968) Fertil. Steril , vol.18 , pp. 353
    • Mahzer, K.1    Kamal, I.2    Hefnani, F.3
  • 86
    • 0017183258 scopus 로고
    • The radiology of the intrauterine contraceptive device
    • Mayall, E. M. T., and Mayall, G. F.: The radiology of the intrauterine contraceptive device. Clin. Radiol. 27: 541, 1976.
    • (1976) Clin. Radiol , vol.27 , pp. 541
    • Mayall, E.1    Mayall, G.F.2
  • 89
    • 0016382433 scopus 로고
    • Laparoscopic removal of intraperitoneal Dalkon Shields: A report of 3 cases
    • Merrill, L., Burd, L. I., and VerBurg, D. J.: Laparoscopic removal of intraperitoneal Dalkon Shields: A report of 3 cases. Am. J. Obstet. Gynecol. 118: 1146, 1974.
    • (1974) Am. J. Obstet. Gynecol , vol.118 , pp. 1146
    • Merrill, L.1    Burd, L.I.2    Verburg, D.J.3
  • 90
    • 0017257454 scopus 로고
    • Accidental insertion of multiple lUDs
    • Millen, A., and Bernstein, G. S.: Accidental insertion of multiple lUDs. Obstet. Gynecol. 47: 369, 1976.
    • (1976) Obstet. Gynecol , vol.47 , pp. 369
    • Millen, A.1    Bernstein, G.S.2
  • 91
    • 84965271338 scopus 로고
    • Uterine perforation by contraceptive devices
    • Mills, W.: Uterine perforation by contraceptive devices. Br. Med. J. 1: 427, 1967.
    • (1967) Br. Med. J , vol.1 , pp. 427
    • Mills, W.1
  • 92
    • 0015511948 scopus 로고
    • Removal of an intraabdominal intrauterine contraceptive device through a peritoneoscope with the use of intraoperative fluoroscopy to aid localization
    • Mountrose, W. E., and Whitehouse, W. L.: Removal of an intraabdominal intrauterine contraceptive device through a peritoneoscope with the use of intraoperative fluoroscopy to aid localization. Am J Obstet. Gynecol 114: 1108, 1972
    • (1972) Am J Obstet. Gynecol , vol.114 , pp. 1108
    • Mountrose, W.E.1    Whitehouse, W.L.2
  • 94
    • 0016076204 scopus 로고
    • Radiographic location of the Daikon shield
    • Mountrose, W. E., and Whitehouse, W. L.: Radiographic location of the Daikon shield. Br. Med. J. 1: 503, 1974
    • (1974) Br. Med. J , vol.1 , pp. 503
    • Mountrose, W.E.1    Whitehouse, W.L.2
  • 95
    • 0014015922 scopus 로고
    • Complications of intrauterine contraceptive devices: Report of 5 cases of ectopic placement of the Bow
    • Nakamoto, M., Buchman, M. I.: Complications of intrauterine contraceptive devices: Report of 5 cases of ectopic placement of the Bow Am. J. Obstet. Gynecol. 94: 1073, 1966.
    • (1966) Am. J. Obstet. Gynecol , vol.94 , pp. 1073
    • Nakamoto, M.1    Buchman, M.I.2
  • 96
    • 0018687611 scopus 로고
    • Real-time ultrasound in locating intrauterine contraceptive devices
    • Nelson, L. H., and Miller, J. B.: Real-time ultrasound in locating intrauterine contraceptive devices. Obstet Gynecol. 54: 711.1979
    • (1979) Obstet Gynecol , vol.54 , pp. 711
    • Nelson, L.H.1    Miller, J.B.2
  • 97
    • 0015224975 scopus 로고
    • Ultrasonic localization of the IUCT: A new technique
    • Nemes, G.. and Kerenyi. T. D.: Ultrasonic localization of the IUCT: A new technique. Am. J. Obstet. Gynecol. 109: 1219, 1971.
    • (1971) Am. J. Obstet. Gynecol , vol.109 , pp. 1219
    • Nemes, G.1
  • 98
    • 0017329984 scopus 로고
    • The diagnosis and removal of occult intrauterine devices
    • Neubüser, D.. and Vahrson, H.: The diagnosis and removal of occult intrauterine devices. Geburtshilfe Frauen-heilkd. 37: 227, 1977.
    • (1977) Geburtshilfe Frauen-Heilkd , vol.37 , pp. 227
    • Neubüser, D.1    Vahrson, H.2
  • 99
    • 84914994874 scopus 로고
    • W. B. Saunders and Company, Philadelphia
    • Neuwirth, R. S.:Hysteroscopy.W. B. Saunders and Company, Philadelphia, 1978, p 52.
    • (1978) Hysteroscopy , pp. 52
    • Neuwirth, R.S.1
  • 100
    • 0018779833 scopus 로고
    • Perforation by intrauterine device
    • Nygren, K.-G.: Perforation by intrauterine device. Lak-artidningen 76: 1709, 1979.
    • (1979) Lak-Artidningen , vol.76 , pp. 1709
    • Nygren, K.-G.1
  • 101
    • 0018129059 scopus 로고
    • Removal of intraabdominal intrauterine contraceptive devices
    • Osborne, J. L., and Bennett, M. J.: Removal of intraabdominal intrauterine contraceptive devices. Br. J. Obstet. Gynaecol. 85: 868, 1978.
    • (1978) Br. J. Obstet. Gynaecol , vol.85 , pp. 868
    • Osborne, J.L.1    Bennett, M.J.2
  • 102
    • 0015102412 scopus 로고
    • Laparoscopic removal of an intra-uterine device
    • Page, S. W., and Monks, P. L.: Laparoscopic removal of an intra-uterine device. Aust. N.Z. J. Obstet. Gynaecol. 11: 192, 1971.
    • (1971) Aust. N.Z. J. Obstet. Gynaecol , vol.11 , pp. 192
    • Page, S.W.1    Monks, P.L.2
  • 103
    • 0014463557 scopus 로고
    • Intrauterine distortion and displacement of IUD
    • Phatak, K. V.: Intrauterine distortion and displacement of IUD. Indian J. Med. Res. 57: 89, 1969.
    • (1969) Indian J. Med. Res , vol.57 , pp. 89
    • Phatak, K.V.1
  • 104
  • 105
    • 0015267755 scopus 로고
    • Ultrasonic localization of intrauterine contraceptive devices
    • Piiroinen, O.: Ultrasonic localization of intrauterine contraceptive devices. Acta Obstet. Gynecol. Scand. 51: 203, 1972.
    • (1972) Acta Obstet. Gynecol. Scand , vol.51 , pp. 203
    • Piiroinen, O.1
  • 106
    • 85039305013 scopus 로고
    • Population Reports, Series B, Number 3: Intrauterine devices. LUDs—Update on Safety, Effectiveness and Research
    • Baltimore, Maryland, May
    • Piiroinen, O.: Population Reports, Series B, Number 3: Intrauterine devices. lUDs—Update on Safety, Effectiveness and Research. Population Information Program, The Johns Hopkins University, Baltimore, Maryland, May, 1979.
    • (1979) Population Information Program, the Johns Hopkins University
    • Piiroinen, O.1
  • 107
    • 0014631911 scopus 로고
    • Perforation of the uterus and partial extrusion of a Lippes loop: Report of a case
    • Post, D. F.: Perforation of the uterus and partial extrusion of a Lippes loop: Report of a case. Obstet. Gynecol. 34: 839, 1969.
    • (1969) Obstet. Gynecol , vol.34 , pp. 839
    • Post, D.F.1
  • 108
    • 0015046953 scopus 로고
    • Uterine perforation by intrauterine contraceptive devices: Diagnosis and treatment
    • Povey, W. G., and Silverman, B.: Uterine perforation by intrauterine contraceptive devices: Diagnosis and treatment. J. Reprod. Med. 6: 196, 1971.
    • (1971) J. Reprod. Med , vol.6 , pp. 196
    • Povey, W.G.1    Silverman, B.2
  • 109
    • 0016394118 scopus 로고
    • Removal of intraperitoneal Daikon shields
    • Powers, J. S., and Hill, J. M.: Removal of intraperitoneal Daikon shields. Am. J. Obstet. Gynecol. 120: 569, 1974.
    • (1974) Am. J. Obstet. Gynecol , vol.120 , pp. 569
    • Powers, J.S.1    Hill, J.M.2
  • 111
    • 0017834888 scopus 로고
    • Lost intrauterine devices and their localization
    • Rao, R. P.: Lost intrauterine devices and their localization. J. Reprod. Med. 20: 195, 1978.
    • (1978) J. Reprod. Med , vol.20 , pp. 195
    • Rao, R.P.1
  • 112
    • 0015507933 scopus 로고
    • Operative removal of intraperitoneal intrauterine contraceptive devices—a reappraisal
    • Roberts, J. M., and Ledger, W. J.: Operative removal of intraperitoneal intrauterine contraceptive devices—a reappraisal. Am. J. Obstet. Gynecol. 112: 863, 1972.
    • (1972) Am. J. Obstet. Gynecol , vol.112 , pp. 863
    • Roberts, J.M.1    Ledger, W.J.2
  • 114
    • 0016614170 scopus 로고
    • Difficult elective removal of a Majzlin spring intrauterine device
    • Robins, J., Mitler, L., Pollack, L., et al.: Difficult elective removal of a Majzlin spring intrauterine device. J. Reprod. Med. 14: 68, 1975.
    • (1975) J. Reprod. Med , vol.14 , pp. 68
    • Robins, J.1    Mitler, L.2    Pollack, L.3
  • 115
    • 0018267770 scopus 로고
    • Copper intrauterine devices in the abdomen
    • Robinson, R. E.: Copper intrauterine devices in the abdomen. Br. Med. J. 2: 1068, 1978.
    • (1978) Br. Med. J , vol.2 , pp. 1068
    • Robinson, R.E.1
  • 117
    • 0014937731 scopus 로고
    • Serioussequellae of intrauterine contraceptive devices
    • Schwartz, G. F., and Markowitz, A. M.: Serioussequellae of intrauterine contraceptive devices. J.A.M.A. 211: 959, 1970.
    • (1970) J.A.M.A , vol.211 , pp. 959
    • Schwartz, G.F.1    Markowitz, A.M.2
  • 118
    • 0017342131 scopus 로고
    • Hysteroscopy: A clinical experience with 320 patients
    • Sciarra, J. J., and Valle, R. F.: Hysteroscopy: A clinical experience with 320 patients. Am. J. Obstet. Gynecol. 127: 340, 1977.
    • (1977) Am. J. Obstet. Gynecol , vol.127 , pp. 340
    • Sciarra, J.J.1    Valle, R.F.2
  • 119
    • 0013855034 scopus 로고
    • Intrauterine contraceptives: An unusual complication
    • Seward, P. J., Burns, G. T., and Quattlebaum, E. G., Intrauterine contraceptives: An unusual complication. J.A.M.A. 194: 1385, 1965.
    • (1965) J.A.M.A , vol.194 , pp. 1385
    • Seward, P.J.1    Burns, G.T.2    Quattlebaum, E.G.3
  • 121
    • 0014471719 scopus 로고
    • Radiographic aspects of perforated intrauterine contraceptive devices
    • Shimkin, P. M., Siegel, H. A., and Seaman, W. B.: Radiographic aspects of perforated intrauterine contraceptive devices. Radiology 92: 353, 1969.
    • (1969) Radiology , vol.92 , pp. 353
    • Shimkin, P.M.1    Siegel, H.A.2    Seaman, W.B.3
  • 122
    • 0015923656 scopus 로고
    • Removal of ectopic intrauterine contraceptive devices aided by laparoscopy. A report of 3 cases and a review of the literature
    • Siegler, A. M.: Removal of ectopic intrauterine contraceptive devices aided by laparoscopy. A report of 3 cases and a review of the literature. Am. J. Obstet. Gynecol. 115: 158, 1973
    • (1973) Am. J. Obstet. Gynecol , vol.115 , pp. 158
    • Siegler, A.M.1
  • 123
    • 85039305237 scopus 로고
    • Medcom Press, New York
    • Siegler, A. M.:Hysterosalpingography.Medcom Press, New York, 1974, pp 193, 196.
    • (1974) Hysterosalpingography , vol.196 , pp. 193
    • Siegler, A.M.1
  • 124
    • 0015409720 scopus 로고
    • Uterine perforation during removal of a broken Majzlin spring
    • Siegler, A. M., and Chen, C.-H.: Uterine perforation during removal of a broken Majzlin spring. Fertil. Steril. 23: 776, 1972.
    • (1972) Fertil. Steril , vol.23 , pp. 776
    • Siegler, A.M.1    Chen, C.-H.2
  • 125
    • 0016827141 scopus 로고
    • Hysteroscopic removal of occult intrauterine contraceptive device
    • Siegler, A. M., and Kemmann, E.: Hysteroscopic removal of occult intrauterine contraceptive device. Obstet. Gynecol. 46: 604, 1975.
    • (1975) Obstet. Gynecol , vol.46 , pp. 604
    • Siegler, A.M.1    Kemmann, E.2
  • 126
    • 0017251703 scopus 로고
    • Location and removal of misplaced or embedded intrauterine devices by hysteroscopy
    • Siegler, A. M., and Kemmann, E.: Location and removal of misplaced or embedded intrauterine devices by hysteroscopy. J. Reprod. Med. 16: 139, 1976.
    • (1976) J. Reprod. Med , vol.16 , pp. 139
    • Siegler, A.M.1    Kemmann, E.2
  • 127
    • 0016677235 scopus 로고
    • Asymptomatic perforation of the uterus with the Copper-7 IUD and its management
    • Sivanesaratnam, V., and Puran, I. S.: Asymptomatic perforation of the uterus with the Copper-7 IUD and its management. Singapore Med. J. 16: 312, 1975.
    • (1975) Singapore Med. J , vol.16 , pp. 312
    • Sivanesaratnam, V.1    Puran, I.S.2
  • 128
    • 0017467311 scopus 로고
    • The detection of intrauterine contraceptive devices by ultrasonic investigation
    • Smith, H. M., Smith, W. I., and Edwards, S. J.: The detection of intrauterine contraceptive devices by ultrasonic investigation. Radiography 43: 60, 1977.
    • (1977) Radiography , vol.43 , pp. 60
    • Smith, H.M.1    Smith, W.I.2    Edwards, S.J.3
  • 130
    • 0016786137 scopus 로고
    • Unusual uses of laparoscopy
    • Söderström, R. M.: Unusual uses of laparoscopy. J Reprod. Med. 15: 77, 1975.
    • (1975) J Reprod. Med , vol.15 , pp. 77
    • Söderström, R.M.1
  • 131
    • 84932411879 scopus 로고
    • The wandering IUD—What to do?
    • edited by Sciarra, J. J., Zatuchni, G. I., and Spiedel, J. J. Harper and Row, Hagerstown, Maryland
    • Söderström, R. M.: The wandering IUD—What to do? InRisks, Benefits and Controversies in Fertility Control, edited by Sciarra, J. J., Zatuchni, G. I., and Spiedel, J. J. Harper and Row, Hagerstown, Maryland, 1978, pp 408-412.
    • (1978) Risks, Benefits and Controversies in Fertility Control , pp. 408-412
    • Söderström, R.M.1
  • 132
    • 0016403001 scopus 로고
    • Translocation of intrauterine contraceptive devices
    • Sparks, R. A.: Translocation of intrauterine contraceptive devices. Lancet 1: 816, 1974.
    • (1974) Lancet , vol.1 , pp. 816
    • Sparks, R.A.1
  • 133
    • 0014815849 scopus 로고
    • Pelvic pneumography with simultenous hysterosalpingography
    • Stern, W. Z., and Wilson, L.: Pelvic pneumography with simultenous hysterosalpingography. Radiology 96: 87, 1970.
    • (1970) Radiology , vol.96 , pp. 87
    • Stern, W.Z.1    Wilson, L.2
  • 134
    • 0015133984 scopus 로고
    • Roentgen evaluation of the ligated fallopian tube
    • Stern, W. Z., and Wilson, L.: Roentgen evaluation of the ligated fallopian tube. Fertil. Steril. 22: 645, 1971.
    • (1971) Fertil. Steril , vol.22 , pp. 645
    • Stern, W.Z.1    Wilson, L.2
  • 135
    • 0017616909 scopus 로고
    • Clinical aspects of intrauterine contraception: Circumspection 1976
    • Tatum, H. J.: Clinical aspects of intrauterine contraception: Circumspection 1976. Fertil. Steril. 28: 3, 1977.
    • (1977) Fertil. Steril , vol.28 , pp. 3
    • Tatum, H.J.1
  • 136
    • 0017852059 scopus 로고
    • Radiologic methods for the localization of lUDs
    • Tetti, A., Torretta, G. M., Carazzone, P. F., et al.: Radiologic methods for the localization of lUDs. Minerva Ginecol. 30: 390, 1978.
    • (1978) Minerva Ginecol , vol.30 , pp. 390
    • Tetti, A.1    Torretta, G.M.2    Carazzone, P.F.3
  • 137
    • 0016394160 scopus 로고
    • Laparoscopic removal of intra-abdominal Daikon shield
    • Thomsen, R. J.: Laparoscopic removal of intra-abdominal Daikon shield. Am. J. Obstet. Gynecol. 120: 566, 1974.
    • (1974) Am. J. Obstet. Gynecol , vol.120 , pp. 566
    • Thomsen, R.J.1
  • 138
    • 0015789772 scopus 로고
    • Radiologic aids to localization of an extrauterine intrauterine contraceptive device
    • Toppozada, H. K., Rizk, M. A., Khowessah, M. M., et al.: Radiologic aids to localization of an extrauterine intrauterine contraceptive device. Fertil. Steril. 24: 170, 1973.
    • (1973) Fertil. Steril , vol.24 , pp. 170
    • Toppozada, H.K.1    Rizk, M.A.2    Khowessah, M.M.3
  • 139
    • 0014921360 scopus 로고
    • Localization of a missing IUD with the help of a plain x-ray examination and a second IUD
    • Tötterman, L. E., and Karjalainen, K.-L.: Localization of a missing IUD with the help of a plain x-ray examination and a second IUD. Acta Obstet. Gynecol. Scand 49: 139, 1970.
    • (1970) Acta Obstet. Gynecol. Scand , vol.49 , pp. 139
    • Tötterman, L.E.1    Karjalainen, K.-L.2
  • 140
    • 0017830234 scopus 로고
    • The causes, diagnosis and treatment of perforations of the uterus by intrauterine devices
    • Treisser, A., and Colau, J. C.: The causes, diagnosis and treatment of perforations of the uterus by intrauterine devices. J. Gynecol. Obstet. Biol. Reprod. (Paris) 7: 837, 1978.
    • (1978) J. Gynecol. Obstet. Biol. Reprod. (Paris) , vol.7 , pp. 837
    • Treisser, A.1    Colau, J.C.2
  • 141
    • 0015897348 scopus 로고
    • Sonographic visualization of a coexisting gestation sac and IUD in the uterus and a consideration of a causative factor of accidental pregnancy
    • Tsai, W.-S., Chen, H.-Y., Chen, Y.-P., et al.: Sonographic visualization of a coexisting gestation sac and IUD in the uterus and a consideration of a causative factor of accidental pregnancy. Int. J. Fertil. 18: 85, 1973.
    • (1973) Int. J. Fertil , vol.18 , pp. 85
    • Tsai, W.-S.1    Chen, H.-Y.2    Chen, Y.-P.3
  • 142
    • 0016661996 scopus 로고
    • Hysteroscopy in the localization and removal of intrauterine devices with missing strings
    • Valle, R. F., and Freeman, D. W.: Hysteroscopy in the localization and removal of intrauterine devices with missing strings." Contraception 11: 161, 1975.
    • (1975) Contraception , vol.11 , pp. 161
    • Valle, R.F.1    Freeman, D.W.2
  • 143
    • 0017336099 scopus 로고
    • Hysteroscopic removal of intrauterine devices with missing filaments
    • Valle, R. F., Sciarra, J. J., and Freeman, D. W.: Hysteroscopic removal of intrauterine devices with missing filaments. Obstet. Gynecol. 49: 55, 1977.
    • (1977) Obstet. Gynecol , vol.49 , pp. 55
    • Valle, R.F.1    Sciarra, J.J.2    Freeman, D.W.3
  • 144
    • 85039304262 scopus 로고
    • Ectopic Lippes loop IUD: Hysterographic study
    • Villabianca, E.: Ectopic Lippes loop IUD: Hysterographic study. Rev. Chil. Obstet. Ginecol. 35: 59, 1970
    • (1970) Rev. Chil. Obstet. Ginecol , vol.35 , pp. 59
    • Villabianca, E.1
  • 146
    • 0016387435 scopus 로고
    • Translocation of intrauterine contraceptive devices
    • Vrijens, M., Thiers, M., and Defoort, P.: Translocation of intrauterine contraceptive devices. Lancet 1: 1165, 1974.
    • (1974) Lancet , vol.1 , pp. 1165
    • Vrijens, M.1    Thiers, M.2    Defoort, P.3
  • 147
    • 0016989133 scopus 로고
    • Sonographic localization of intra-uterine contraceptive devices
    • Watt, I., Halliwell, M., and Ross, F. G. M.: Sonographic localization of intra-uterine contraceptive devices. Br. J. Med. 49: 731, 1976.
    • (1976) Br. J. Med , vol.49 , pp. 731
    • Watt, I.1    Halliwell, M.2    Ross, F.3
  • 148
    • 0016637314 scopus 로고
    • Complications of intrauterine contraceptive devices
    • Weekes, L. R.: Complications of intrauterine contraceptive devices. J. Natl. Med. Assoc. 67: 1, 1975
    • (1975) J. Natl. Med. Assoc , vol.67 , pp. 1
    • Weekes, L.R.1
  • 149
    • 0014417165 scopus 로고
    • Perforation of the uterine wall by the Lippes loop
    • Wei, P. Y.: Perforation of the uterine wall by the Lippes loop. Am. J. Obstet. Gynecol. 101: 770, 1968.
    • (1968) Am. J. Obstet. Gynecol , vol.101 , pp. 770
    • Wei, P.Y.1
  • 151
    • 0014017255 scopus 로고
    • Ultrasound detection of intrauterine contraceptive devices
    • Winters, H. S.: Ultrasound detection of intrauterine contraceptive devices. Am. J. Obstet. Gynecol. 95: 880, 1966.
    • (1966) Am. J. Obstet. Gynecol , vol.95 , pp. 880
    • Winters, H.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.