메뉴 건너뛰기




Volumn 15, Issue 5, 1981, Pages 619-653

Friction and wear properties of polymer, metal, and ceramic prosthetic joint materials evaluated on a multichannel screening device

Author keywords

[No Author keywords available]

Indexed keywords

CERAMIC PRODUCTS - WEAR; POLYETHYLENES - WEAR; STAINLESS STEEL - WEAR;

EID: 0019620861     PISSN: 00219304     EISSN: 10974636     Source Type: Journal    
DOI: 10.1002/jbm.820150503     Document Type: Article
Times cited : (233)

References (50)
  • 2
    • 0016972816 scopus 로고
    • The Friction and Wear Behavior of Polyoxymethylene in Connection with Joint Replacement
    • (1976) Wear , vol.38 , pp. 291-303
    • Shen, C.1    Dumbleton, J.H.2
  • 4
    • 0016319321 scopus 로고
    • The Friction and Wear Behavior of Irradiated Very High‐Molecular‐Weight Polyethylene
    • (1974) Wear , vol.30 , pp. 349-364
    • Shen, C.1    Dumbleton, J.H.2
  • 6
    • 84989611715 scopus 로고
    • “Effect of Sterilization Irradiation on Friction and Wear of Ultrahigh‐Molecular‐Weight Polyethylene,” NASA Technical Paper 1462, May
    • (1979)
    • Jones, W.1    Hady, W.2    Crugnola, A.3
  • 8
    • 84989662378 scopus 로고
    • “Increased Wear of UHMW Polyethylene after Gamma Radiation Sterilization,” Proceedings of the 26th Annual Meeting of the Orthopaedic Research Society, Feb.
    • (1980)
    • McKellop, H.1    Griffin, G.2    Clarke, I.3    Markolf, K.4
  • 9
    • 84989637545 scopus 로고
    • “Wear Screening Tests with Potentially Superior Prosthetic Bearing Materials,” Transactions of the 23rd Annual Meeting of the Orthopaedic Research Society, February
    • (1977)
    • McKellop, H.1    Markolf, K.2    Clarke, I.3    Amstutz, H.4
  • 26
    • 84989613760 scopus 로고
    • “A New Generation of Artificial Joints with the Best Choice of Implant Materials,” Sulzer Tech. Rev., No. 2
    • (1973)
    • Semlitsch, M.1
  • 28
    • 84989613765 scopus 로고
    • “The Wear of Polyethylene Sockets in M. E. Müller Total Hip Prostheses,” Paper No. 9, Transactions of the 4th Annual Meeting of the Society for Biomaterials, May
    • (1978)
    • Kriete, U.1    Willert, H.2    Semlitsch, M.3
  • 29
    • 84989629570 scopus 로고
    • “Biophase Implant Material Technical Information,” Technical Publication No. 3846, Richards Mfg., Memphis, TN
    • (1980)
  • 31
    • 84989619482 scopus 로고
    • Dept. of Materials Engineering, University of Illinois, Chicago, IL, personal communication, November, data in preparation for publication.
    • (1979)
    • Rostoker, W.1
  • 33
    • 84989649463 scopus 로고
    • The Hospital for Special Surgery, New York, N. Y., personal communication, June, data in preparation for publication.
    • (1978)
    • Trent, P.1
  • 34
    • 84989613792 scopus 로고
    • “Hip Simulator Wear Testing Summary for Ti‐6Al‐4V,” Technical Memorandum No. 319, Zimmer USA, Warsaw, IN, January 25
    • (1980)
    • Greer, K.1
  • 40
    • 0345599682 scopus 로고
    • Factors in the Design of an Artificial Hip Joint
    • Paper 2 in Lubrication and Wear in Living and Artificial Human Joints, Pt. 3J
    • (1966) Proc. Inst. Mech. Engr. , vol.181 , pp. 104-111
    • Charnley, J.1
  • 42
    • 84989658482 scopus 로고
    • “Technical Progress in Artificial Hip Joints,” Sulzer Tech. Rev., No. 4
    • (1974)
    • Semlitsch, M.1
  • 43
    • 84989637564 scopus 로고
    • “Local Tissue Biocompatibility,” Report of a Workshop on Fundamental Studies for Internal Structural Prostheses, Charlottesville, VA, April
    • (1972) , pp. 43-45
    • Coulson, W.1    Gruen, T.2    Amstutz, H.3
  • 47
    • 84989608032 scopus 로고
    • “Friction and Wear Behavior of Prosthetic Cartilage Materials Under Simulated In Vivo Conditions,” presented at the 18th Annual Meeting of the Orthopaedic Research Society
    • (1972)
    • Homsy, C.1    King, J.2
  • 49
    • 84989660111 scopus 로고
    • Report on Carbon Fiber Reinforced Polyethylene, Zimmer USA, Warsaw, Indiana, January 27
    • (1978)
  • 50
    • 84989644336 scopus 로고
    • “Postmortem Analysis of Carbon‐Fiber Reinforced UHMWPE and UHMWPE Prostheses Retrieved from a Single Subject after a Service Life of 12 to 15 Months,” Transactions of the 24th Annual Meeting of the Orthopaedic Research Society
    • (1978) , pp. 186
    • Groth, H.1    Shen, G.2    Gilbertson, L.3    Farling, G.4    Shilling, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.