메뉴 건너뛰기




Volumn 28, Issue 4, 1981, Pages 242-247

A Multigate Pulsed Doppler System with Serial Data Processing

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD FLOWMETRY; CARDIOVASCULAR SYSTEM; COMPUTER ANALYSIS; DOPPLER FLOWMETER; INFORMATION PROCESSING; METHODOLOGY; ULTRASOUND;

EID: 0019394050     PISSN: 00189537     EISSN: None     Source Type: Journal    
DOI: 10.1109/T-SU.1981.31254     Document Type: Article
Times cited : (53)

References (13)
  • 1
    • 0005483798 scopus 로고
    • in Computers in Medicine Series D. W. Hill, Gen. Ed. Reading, MA: Butterworth
    • M. H. Ackroyd, Digital filters, in Computers in Medicine Series, D. W. Hill, Gen. Ed. Reading, MA: Butterworth, 1973.
    • (1973) Digital filters
    • Ackroyd, M.H.1
  • 3
    • 0017905078 scopus 로고
    • Topoflow—A digital full range Doppler velocity meter
    • M. Brandestini, “Topoflow—A digital full range Doppler velocity meter,” IEEE Trans Son. Ultrason., vol. SU-26, p. 287, 1978.
    • (1978) IEEE Trans Son. Ultrason. , vol.SU-26 , pp. 287
    • Brandestini, M.1
  • 4
    • 0018053034 scopus 로고
    • Blood flow imaging using a discrete time-frequency meter
    • Cat. 78 CH 1344-1SU
    • “Blood flow imaging using a discrete time-frequency meter,” in Proc. IEEE, Ultrasonic Symp., Cat. 78 CH 1344-1SU, pp. 348–352, 1978.
    • (1978) Proc. IEEE, Ultrasonic Symp. , pp. 348-352
  • 5
    • 0016678430 scopus 로고
    • Multichannel, direction resolving Doppler angiography
    • Amsterdam
    • P. J. Fish, “Multichannel, direction resolving Doppler angi ography,” Excerpta Medica, Amsterdam, pp. 153–159, 1975.
    • (1975) Excerpta Medica , pp. 153-159
    • Fish, P.J.1
  • 6
    • 0000293183 scopus 로고
    • Theory of communications
    • Nov.
    • D. Gabor, “Theory of communications,” J. IEE, vol. 93 (III), pp. 429–457, Nov. 1946.
    • (1946) J. IEE , vol.93 , pp. 429-457
    • Gabor, D.1
  • 7
    • 0017185777 scopus 로고
    • Measurements of disordered flows distal to subtotal vascular stenosis in the thoracic aortas of dogs
    • D. P. Giddens, R. F. Mahon, and R. A. Cassanova, “Measurements of disordered flows distal to subtotal vascular stenosis in the thoracic aortas of dogs,” Circ. Res., vol. 39, pp. 112–119, 1976.
    • (1976) Circ. Res. , vol.39 , pp. 112-119
    • Giddens, D.P.1    Mahon, R.F.2    Cassanova, R.A.3
  • 9
    • 84911529679 scopus 로고
    • A novel pulsed directional Doppler velocity-meter, the phasedetection profilometer
    • May E. Kazner, ed. Munich, Germany
    • P. A. Grandchamp, “A novel pulsed directional Doppler velocity-meter, the phasedetection profilometer,” in Proc. 2nd European Congress on Ultrasonics in Medicine. E. Kazner, ed. Munich, Germany, pp. 122–132, May 12-16, 1975.
    • (1975) Proc. 2nd European Congress on Ultrasonics in Medicine. , pp. 122-132
    • Grandchamp, P.A.1
  • 11
    • 0001850186 scopus 로고
    • Theoretical and practical aspects of pulsed Doppler flowmetry: real-time application to the measure of instantaneous velocity profiles
    • R. S. Reneman, ed. Amsterdam, Holland North-Holland
    • F.A. Peronneau, J. P. Bournat, A. Bugon, A. Barbet, and M. Xhaard, “Theoretical and practical aspects of pulsed Doppler flowmetry: real-time application to the measure of instantaneous velocity profiles in vitro and in vivo,” in Cardiovascular applications of Ultrasound, R. S. Reneman, ed. Amsterdam, Holland: North-Holland, 1974, pp. 66–84.
    • (1974) Cardiovascular applications of Ultrasound , pp. 66-84
    • Peronneau, F.A.1    Bournat, J.P.2    Bugon, A.3    Barbet, A.4    Xhaard, M.5
  • 12
    • 84909514436 scopus 로고
    • Difficulties in processing of an analogue Doppler flow signal; With special reference to zero-crossing meters and quantification
    • R. S. Reneman, ed. Amsterdam, Holland North-Holland
    • R. S. Reneman and M. P. Spencer, “Difficulties in processing of an analogue Doppler flow signal; With special reference to zero-crossing meters and quantification,” in Cardiovascular applications of Ultrasound, R. S. Reneman, ed. Amsterdam, Holland: North-Holland, 1974, pp. 32–42.
    • (1974) Cardiovascular applications of Ultrasound , pp. 32-42
    • Reneman, R.S.1    Spencer, M.P.2
  • 13
    • 84910252262 scopus 로고    scopus 로고
    • Turbulenzmessung mit dem Doppler-UItraschallverfahren: Eine neue Methode der Qualitatskontrolle in der Arterienchirurgie
    • A. Kriesmann, and A. Bollinger, Ed. Stuttgart Germany Georg Thieme Verlag
    • W. Sandmann, P. Peronneau, G. Schweins, J. Bournat, and J. Hinglais, “Turbulenzmessung mit dem Doppler-UItraschallverfahren: Eine neue Methode der Qualitatskontrolle in der Arterienchirurgie,” in Ultraschall-Doppler-Diagnostik in der Angiologie, A. Kriesmann, and A. Bollinger, Ed. Stuttgart, Germany: Georg Thieme Verlag, pp. 77–81.
    • Ultraschall-Doppler-Diagnostik in der Angiologie , pp. 77-81
    • Sandmann, W.1    Peronneau, P.2    Schweins, G.3    Bournat, J.4    Hinglais, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.