메뉴 건너뛰기




Volumn 8, Issue 4-6, 1980, Pages 369-388

Controlled prehension and release in the C5 quadriplegic elicited by functional electrical stimulation of the paralyzed forearm musculature

Author keywords

[No Author keywords available]

Indexed keywords

CONTROL EQUIPMENT, ELECTRIC - MEDICAL APPLICATIONS; CONTROL SYSTEMS, PROPORTIONAL - MEDICAL APPLICATIONS;

EID: 0019252903     PISSN: 00906964     EISSN: 15739686     Source Type: Journal    
DOI: 10.1007/BF02363440     Document Type: Article
Times cited : (106)

References (31)
  • 4
    • 84932387006 scopus 로고    scopus 로고
    • Brittain, R.H. and R.N. Scott. Sensory feedback in a myoelectric prosthesis. University of New Brunswick Research Report 78.1:February, 1978.
  • 5
    • 84932290325 scopus 로고    scopus 로고
    • Buckett, J.R., P.H. Peckham, and R.B. Strother. Shoulder position control; An alternative control technique for motion impaired individuals. Proceedings of the International Conference on Rehabilitation Engineering. Toronto, 1980, pp.244–247.
  • 11
    • 84932393024 scopus 로고    scopus 로고
    • Jablonski, E., P.H. Peckham, and W.H. Ko. An RF powered implantable multichannel muscle stimulator. Proceedings of 28th Annual Conf. Eng. Med. Biol. 1975, p. 100.
  • 12
    • 84932378376 scopus 로고    scopus 로고
    • Keller, A.D., C.L. Taylor, and V. Zahm. Studies to determine the functional requirements for hand and arm prosthesis. Final Report to National Academy of Sciences Contract No. VAm-21223, 1947.
  • 15
    • 84932301491 scopus 로고    scopus 로고
    • Long, C., II. Normal and abnormal motor control in the upper extremities. Final Report Social and Rehabilitation Services, Grant No. RD-2377-M, 52–83, 1970.
  • 17
    • 84932376567 scopus 로고    scopus 로고
    • Mortimer, J.R., P.H. Peckham, and P.E. Crago. Intramuscular electrical stimulation of skeletal muscle Eleventh Progress Report to NIH-NINCDS, Contract No. NO1-NS-2-2314, June, 1977.
  • 19
    • 84932345485 scopus 로고    scopus 로고
    • Peckham, P.H. Control of contraction strength of electrically stimulated muscle by pulse width and frequency modulation, Proceedings of the 29th Annual Conf. on Eng. in Med. and Biol. in Boston, MA., 1976, p. 116.
  • 20
    • 84932298217 scopus 로고    scopus 로고
    • Peckham, P.H., E.B. Marsolasis, and J.T. Mortimer. Restoration of key grip and release in the C6 tetraplegic through functional electrical stimulation. J. Hand Surg. 462–470, Sept. 1980.
  • 23
    • 84932380748 scopus 로고    scopus 로고
    • Peckham, P.H., J.T. Mortimer, and E.B. Marsolais. Percutaneous intramuscular excitation of paralyzed skeletal muscle: Electrode performance. In: Intramuscular Electrical Stimulation of Skeletal Muscle, edited by J.T. Mortimer. Fourteenth Progress Report to NIH-NINCDS, Contract No. NO1-NS-2-2314, December, 1979.
  • 28
    • 0014508666 scopus 로고
    • The influence of activity in some contractile characteristics of mammlian fast and slow muscles
    • (1969) J. Physiol. , vol.201 , pp. 535-549
    • Salmons, S.1    Vrbova, G.2
  • 29
    • 84932342919 scopus 로고    scopus 로고
    • Saunders, F. Electrotactile sensory aids for the handicapped. Proceedings of the 4th Annual Meeting of the Biomedical Engineering Society. Los Angeles, CA, 1973.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.