메뉴 건너뛰기




Volumn BME-27, Issue 3, 1980, Pages 132-138

A New Instrument for the Simultaneous Measurement of Total Hemoglobin; % Oxyhemoglobin, % Carboxyhemoglobin, % Methemoglobin, and Oxygen Content in Whole Blood

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL MATERIALS - BLOOD; COMPUTERS, DIGITAL - SPECIAL PURPOSE APPLICATION; COMPUTERS, MINIATURE - APPLICATIONS; SPECTROPHOTOMETERS;

EID: 0019230982     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.1980.326613     Document Type: Article
Times cited : (47)

References (16)
  • 1
    • 0014958286 scopus 로고
    • Endogenous carbon monoxide production
    • R. F. Cobuin, “Endogenous carbon monoxide production,” New Eng. J. Med., vol. 282, pp. 207–209, 1970.
    • (1970) New Eng. J. Med. , vol.282 , pp. 207-209
    • Cobuin, R.F.1
  • 3
    • 84907040878 scopus 로고
    • Blood oxygen saturation determined spectrophotometrically
    • W. Falholt, “Blood oxygen saturation determined spectropho-tometrically,” Scand. J. Clin. Lab. Investigation, vol. 15, pp. 67–72, 1963.
    • (1963) Scand. J. Clin. Lab. Investigation , vol.15 , pp. 67-72
    • Falholt, W.1
  • 4
    • 0016032020 scopus 로고
    • A new method for rapid determination of carboxyhemoglobin by use of double-wavelength spectrophotometry
    • A. Ramieri, Jr., P. Jatlow, and D. Seligson, “A new method for rapid determination of carboxyhemoglobin by use of double-wavelength spectrophotometry,” Clin. Chem., vol. 20, pp. 278–281, 1974.
    • (1974) Clin. Chem. , vol.20 , pp. 278-281
    • Ramieri, A.1    Jatlow, P.2    Seligson, D.3
  • 5
    • 84939070582 scopus 로고
    • Spectrophotometric determination of hemoglobin concentration and % oxyhemoglobin and % carboxyhemoglobin saturation
    • presented at the Amer. Ass. Clin. Chem., 20th Nat. Meeting, Aug. 19
    • A. L. Malenfant, S. R. Gambino, A. J. Waraksa, and E. I. Roe, “Spectrophotometric determination of hemoglobin concentration and % oxyhemoglobin and % carboxyhemoglobin saturation,” presented at the Amer. Ass. Clin. Chem., 20th Nat. Meeting, Aug. 19, 1968.
    • (1968)
    • Malenfant, A.L.1    Gambino, S.R.2    Waraksa, A.J.3    Roe, E.I.4
  • 6
    • 84934171641 scopus 로고
    • Chicago, IL: Amer. Ass. Clin. Pathologists
    • S. R. Gambino, Hemoglobinometry. Chicago, IL: Amer. Ass. Clin. Pathologists, 1967, pp. 35–46.
    • (1967) Hemoglobinometry , pp. 35-46
    • Gambino, S.R.1
  • 7
    • 0000337808 scopus 로고
    • The determination of gases in blood and other solutions by vacuum extraction and manometric measurement
    • D. D. Van Slyke and J. M. Neill, “The determination of gases in blood and other solutions by vacuum extraction and mano-metric measurement,” Int. J. Biol. Chem., vol. 61, pp. 523–557, 1924.
    • (1924) Int. J. Biol. Chem. , vol.61 , pp. 523-557
    • Van Slyke, D.D.1    Neill, J.M.2
  • 8
    • 0001302058 scopus 로고
    • Determination of carbon monoxide in blood by gas chromatography
    • H. A. Cortison, F. L. Rodkey, and J. D. O'Neal, “Determination of carbon monoxide in blood by gas chromatography,” Clin. Chem., vol. 14, pp. 162–171, 1968.
    • (1968) Clin. Chem. , vol.14 , pp. 162-171
    • Cortison, H.A.1    Rodkey, F.L.2    O'Neal, J.D.3
  • 9
    • 84939048981 scopus 로고    scopus 로고
    • LEX-O2-CON, Lexington Instr. Corp., 241 Crescent St., Waltham, MA 02154.
    • LEX-O2-CON, Lexington Instr. Corp., 241 Crescent St., Waltham, MA 02154.
  • 10
    • 0000400174 scopus 로고
    • Microdetermination of oxyhemoglobin, methemoglobin, and sulfhemoglobin in a single sample of blood
    • K. A. Evelyn and H. T. Malloy, “Microdetermination of oxyhemoglobin, methemoglobin, and sulfhemoglobin in a single sample of blood,” J. Biol. Chem., vol. 126, pp. 655–662, 1938.
    • (1938) J. Biol. Chem. , vol.126 , pp. 655-662
    • Evelyn, K.A.1    Malloy, H.T.2
  • 11
    • 0016044190 scopus 로고
    • Effects of carboxyhemoglobin on the determination of methemoglobin in blood
    • F. L. Rodkey and J. D. O'Neal, “Effects of carboxyhemoglobin on the determination of methemoglobin in blood,” Biochem. Med., vol. 9, pp. 261–270, 1974.
    • (1974) Biochem. Med. , vol.9 , pp. 261-270
    • Rodkey, F.L.1    O'Neal, J.D.2
  • 12
    • 0015426712 scopus 로고
    • Hemoglobin pigments. Spectrophotometric determination of oxy-, carboxy-, met-, and sulfhemoglobin in capillary blood
    • O. Siggard-Andersen, B. Nørgaard-Pedersen, and J. Rem, “Hemoglobin pigments. Spectrophotometric determination of oxy-, carboxy-, met-, and sulfhemoglobin in capillary blood,” Clinica Chimica Acta, vol. 42, pp. 85–100, 1972.
    • (1972) Clinica Chimica Acta , vol.42 , pp. 85-100
    • Siggard-Andersen, O.1    Nørgaard-Pedersen, B.2    Rem, J.3
  • 13
    • 0004204990 scopus 로고
    • Spectrophotometry of Haemoglobin Derivatives
    • Assen, The Netherlands: Thomas
    • O. W. Van Assendelft, Spectrophotometry of Haemoglobin Derivatives. Assen, The Netherlands: Thomas, 1970, pp. 55–65.
    • (1970) , pp. 55-65
    • Van Assendelft, O.W.1
  • 14
    • 84939009486 scopus 로고    scopus 로고
    • Intel Corp., 3065 Bowers Ave., Santa Clara, CA 95051.
    • Intel 4004 Microcomputer, Intel Corp., 3065 Bowers Ave., Santa Clara, CA 95051.
  • 15
    • 84939025364 scopus 로고    scopus 로고
    • IL 813, 713, or 513 Blood Gas Analyzer, Instrumentation Lab. Inc., 113 Hartwell Ave., Lexington, MA 02173.
    • IL 813, 713, or 513 Blood Gas Analyzer, Instrumentation Lab. Inc., 113 Hartwell Ave., Lexington, MA 02173.
  • 16
    • 0013967281 scopus 로고
    • Mixing technique for the oxygen-hemoglobin equilibrium and Bohr effect
    • M. J. Edwards and R. J. Martin, “Mixing technique for the oxygen-hemoglobin equilibrium and Bohr effect,” J. Appl. Physiol., vol. 21, pp. 1898–1902, 1966.
    • (1966) J. Appl. Physiol. , vol.21 , pp. 1898-1902
    • Edwards, M.J.1    Martin, R.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.