메뉴 건너뛰기




Volumn 27, Issue 6, 1980, Pages 287-294

Ultrasound Phased Array Delay Lines Based on Quadrature Sampling Techniques

Author keywords

[No Author keywords available]

Indexed keywords

SIGNAL PROCESSING;

EID: 0019079345     PISSN: 00189537     EISSN: None     Source Type: Journal    
DOI: 10.1109/T-SU.1980.31192     Document Type: Article
Times cited : (25)

References (15)
  • 1
    • 0014302915 scopus 로고
    • Electronic sector scanning for ultrasonic diagnosis
    • J. C. Somer, “Electronic sector scanning for ultrasonic diagnosis,” Ultrasonics, vol. 6, pp. 153–159, 1968.
    • (1968) Ultrasonics , vol.6 , pp. 153-159
    • Somer, J.C.1
  • 2
    • 0008753055 scopus 로고
    • A new ultrasound imaging technique employing two dimensional electronic beam steering
    • New York: : Plenum
    • F. L. Thurstone and O. T. Von Ramm, “A new ultrasound imaging technique employing two dimensional electronic beam steering,” in Acoustical Holography, vol. 5. New York: Plenum, 1973.
    • (1973) Acoustical Holography , vol.5
    • Thurstone, F.L.1    Von Ramm, O.T.2
  • 4
    • 0015722111 scopus 로고
    • Ultrasound axicon: a device for focusing over a large depth
    • C. B. Burckhardt, H. Hoffmann, and P. A. Grandchamp,” “Ultrasound axicon: a device for focusing over a large depth,” J. Acoust. Soc. Amer., vol. 54, no. 6, pp. 1628–1630, 1973.
    • (1973) J. Acoust. Soc. Amer. , vol.54 , Issue.6 , pp. 1628-1630
    • Burckhardt, C.B.1    Hoffmann, H.2    Grandchamp, P.A.3
  • 5
    • 84939356324 scopus 로고
    • An electrically variable analogue delay achieved by fast consecutively commutated capacitors
    • Progress Rep. 3, Inst. Med. Phys. TNO, Da Costakade 45, Utrecht, The Netherlands
    • P. Doornbos and J. C. Somer, “An electrically variable analogue delay achieved by fast consecutively commutated capacitors,” Progress Rep. 3, Inst. Med. Phys. TNO, Da Costakade 45, Utrecht, The Netherlands, 1972.
    • (1972)
    • Doornbos, P.1    Somer, J.C.2
  • 6
    • 84939345311 scopus 로고
    • Evaluation of novel dynamically variable electronic delay lines for ultrasonic imaging
    • New York: : Plenum
    • R. E. McKeighen and M. P. Buchin, “Evaluation of novel dynamically variable electronic delay lines for ultrasonic imaging,” Ultrasound in Med., vol. 4. New York: Plenum, 1977.
    • (1977) Ultrasound in Med. , vol.4
    • McKeighen, R.E.1    Buchin, M.P.2
  • 7
    • 0017789885 scopus 로고
    • New techniques for dynamically variable electronic delays for real time ultrasonic imaging
    • R. E. McKeighen and M. P. Buchin, “New techniques for dynamically variable electronic delays for real time ultrasonic imaging,” Proc. IEEE Ultrason. Symp., 1977.
    • (1977) Proc. IEEE Ultrason. Symp.
    • McKeighen, R.E.1    Buchin, M.P.2
  • 8
    • 84939397639 scopus 로고
    • A digitally controlled CCD dynamically focused phased array
    • J. T. Walker and J. D. Meindl, “A digitally controlled CCD dynamically focused phased array,” Proc. IEEE Ultrason. Symp., 1975.
    • (1975) Proc. IEEE Ultrason. Symp.
    • Walker, J.T.1    Meindl, J.D.2
  • 9
    • 21644467865 scopus 로고
    • A simplified ultrasound phased array sector scanner
    • C. T. Lancee, Ed. The Netherlands: Martinus Nijhoff
    • C. B. Burekhardt, P. A. Grandchamp, H. Hoffman, and R. Fehr, “A simplified ultrasound phased array sector scanner,” in Echo-cardiology, cardiology, C. T. Lancee, Ed. The Netherlands: Martinus Nijhoff, pp. 385–393, 1979.
    • (1979) Echo-cardiology, cardiology , pp. 385-393
    • Burekhardt, C.B.1    Grandchamp, P.A.2    Hoffman, H.3    Fehr, R.4
  • 10
    • 0014797429 scopus 로고
    • Pulsed doppler blood flow sensing
    • D. W. Baker, “Pulsed doppler blood flow sensing,” IEEE Trans. Son. Ultrason., vol. SU-17, pp. 170–185, 1970.
    • (1970) IEEE Trans. Son. Ultrason. , vol.SU-17 , pp. 170-185
    • Baker, D.W.1
  • 11
    • 0017905078 scopus 로고
    • Topoflow-A digital full range doppler velocity meter
    • M. A. Brandestini, “Topoflow-A digital full range doppler velocity meter,” IEEE Trans. Son. Ultrason., vol. SU-25, pp. 287–293, 1978.
    • (1978) IEEE Trans. Son. Ultrason. , vol.SU-25 , pp. 287-293
    • Brandestini, M.A.1
  • 12
    • 0018124830 scopus 로고
    • Annular array design and logarithmic processing for ultrasonic imaging
    • H. E. Melton and F. L. Thurstone, “Annular array design and logarithmic processing for ultrasonic imaging,” Ultrasound Med. Biol., vol. 4, 1–12, 1978.
    • (1978) Ultrasound Med. Biol. , vol.4 , pp. 1-12
    • Melton, H.E.1    Thurstone, F.L.2
  • 13
    • 36849136620 scopus 로고
    • Exact interpolation of bandlimited functions
    • A. W. Kohlenburg, “Exact interpolation of bandlimited functions,” tions,” J. Appl. Phys., vol. 24, pp. 1432–1436, 1953.
    • (1953) J. Appl. Phys. , vol.24 , pp. 1432-1436
    • Kohlenburg, A.W.1
  • 14
    • 0003945962 scopus 로고
    • Quadrature sampling of high frequency waveforms
    • O. D. Grace and S. P. Pitt, “Quadrature sampling of high frequency waveforms,” J. Acoust. Soc. Amer., vol. 44, pp. 1453–1454, 1454, 1968.
    • (1968) J. Acoust. Soc. Amer. , vol.44 , pp. 1453-1454
    • Grace, O.D.1    Pitt, S.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.