메뉴 건너뛰기




Volumn PAS-99, Issue 4, 1980, Pages 1456-1465

Diagnostic technique of gas insulated substation by partial discharge detection

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC DISCHARGES; ELECTRIC MEASUREMENTS - VOLTAGE; GASES - DECOMPOSITION; PHOTODETECTORS - APPLICATIONS; VIBRATIONS - MEASUREMENTS;

EID: 0019044046     PISSN: 00189510     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPAS.1980.319569     Document Type: Article
Times cited : (54)

References (12)
  • 1
    • 84939399107 scopus 로고
    • Influence of arcdecomposed SF6 gas on cast epoxy insulators for gas insulated switchgears
    • paper F 79 290-8 IEEE PES Winter Meeting
    • S. Tominaga, H. Kuwahara and K. Hirooka, “Influence of arcdecomposed SF6 gas on cast epoxy insulators for gas insulated switchgears”, paper F 79 290-8 IEEE PES Winter Meeting, 1979.
    • (1979)
    • Tominaga, S.1    Kuwahara, H.2    Hirooka, K.3
  • 2
    • 84939382064 scopus 로고
    • The ERA discharge detectors
    • G. Mole, “The ERA discharge detectors”, ERA Rep. V/T 149, 1962.
    • (1962) ERA Rep. , vol.149
    • Mole, G.1
  • 3
    • 84939366741 scopus 로고
    • Testing of gas insulated substations and transmission system
    • paper T 73 366-2 IEEE PES Summer meeting
    • H.W. Graybill, “Testing of gas insulated substations and transmission system”, paper T 73 366-2 IEEE PES Summer meeting, 1973.
    • (1973)
    • Graybill, H.W.1
  • 6
    • 84939380582 scopus 로고
    • The maintenance standard of SF6 gas insulated equipments
    • Technical Committee on the Maintenance Standard of SF6 Gas Insulated Equipments, “The maintenance standard of SF6 gas insulated equipments”, Denki Kyodo Kenkyu, vol. 33, No. 4, 1977.
    • (1977) Denki Kyodo Kenkyu , vol.33 , Issue.4
  • 8
    • 84939380841 scopus 로고
    • Transient groundrise in SF6 substations investigated
    • August
    • G.L. Ford, S.A. Boggs and F.Y. Chu, “Transient groundrise in SF6 substations investigated”, Transmission & Distribution, vol. 31, August 1979.
    • (1979) Transmission & Distribution , vol.31
    • Ford, G.L.1    Boggs, S.A.2    Chu, F.Y.3
  • 9
    • 84939388605 scopus 로고
    • Partial Discharge Location in Gas-Insulated Switchgear
    • Knoxville, TN. USA, 9–13 March, Proceedings published by Pergamon Press.
    • Boggs, S. A., Ford, G. L. and Chu, F. Y., “Partial Discharge Location in Gas-Insulated Switchgear”, Second International Symposium on Gaseous Dielectrics, Knoxville, TN. USA, 9–13 March 1980. Proceedings published by Pergamon Press.
    • (1980) Second International Symposium on Gaseous Dielectrics
    • Boggs, S.A.1    Ford, G.L.2    Chu, F.Y.3
  • 11
    • 84946968674 scopus 로고
    • Transient High Voltages on the Grounded Enclosures of Gas-Insulated Transmission Equipment
    • Knoxville, TN, USA, 9–13 March, Proceedings published by Pergamon Press.
    • Ford, G. L. and Boggs, S. A., “Transient High Voltages on the Grounded Enclosures of Gas-Insulated Transmission Equipment”, Second International Symposium on Gaseous Dielectrics, Knoxville, TN, USA, 9–13 March 1980. Proceedings published by Pergamon Press.
    • (1980) Second International Symposium on Gaseous Dielectrics
    • Ford, G.L.1    Boggs, S.A.2
  • 12
    • 84948592264 scopus 로고
    • Decomposition Products of SF6 by High-Current Arc and Their Reaction Mechanism
    • K. Hirooka, H. Kuwahara, M. Noshiro and Y. Jitsugiri, “Decomposition Products of SF6 by High-Current Arc and Their Reaction Mechanism”, Electrical Engineering in Japan, Vol. 95, No. 6, 1975.
    • (1975) Electrical Engineering in Japan , vol.95 , Issue.6
    • Hirooka, K.1    Kuwahara, H.2    Noshiro, M.3    Jitsugiri, Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.