메뉴 건너뛰기




Volumn 12, Issue SUPPL. 1, 1996, Pages 28-32

Pet state-of-the-art instrumentation

Author keywords

Emission computed tomography; Instrumentation; Positron emission tomography

Indexed keywords


EID: 0013587590     PISSN: 11201797     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (14)
  • 1
    • 0542401363 scopus 로고
    • Positron instrumentation
    • Lawrence JH, Budinger TF. Eds. New York, NY. Grune & Stratton
    • Brownell GL, Correia JA, Zamenhof RG. Positron instrumentation. In: Recent Advances in Nuclear Medicine, Vol. 5. Lawrence JH, Budinger TF. Eds. New York, NY. Grune & Stratton 1978; 1-50.
    • (1978) Recent Advances in Nuclear Medicine , vol.5 , pp. 1-50
    • Brownell, G.L.1    Correia, J.A.2    Zamenhof, R.G.3
  • 2
    • 0017928649 scopus 로고
    • Positome II: A high efficiency positron imaging device for dynamic brain studies
    • Thompson CJ, Yamamoto YL, Meyer E. Positome II: A high efficiency positron imaging device for dynamic brain studies. IEEE Trans Nucl Sci 1979: NS-26; 583-589.
    • (1979) IEEE Trans Nucl Sci , vol.NS-26 , pp. 583-589
    • Thompson, C.J.1    Yamamoto, Y.L.2    Meyer, E.3
  • 3
    • 0018860134 scopus 로고
    • Design of a high resolution positron emission tomograph: The Neuro-PET
    • Brooks RA, Sank VJ, Di Chiro G, et al. Design of a high resolution positron emission tomograph: The Neuro-PET. J Comput Assist Tomogr 1980: 4; 5-13.
    • (1980) J Comput Assist Tomogr , vol.4 , pp. 5-13
    • Brooks, R.A.1    Sank, V.J.2    Di Chiro, G.3
  • 4
    • 0019525907 scopus 로고
    • A four ring positron camera system for emission tomography of the brain
    • Eriksson L, Bohm C, Kesselberg M, et al. A four ring positron camera system for emission tomography of the brain. IEEE Trans Nucl Sci 1982: NS-29; 539-543.
    • (1982) IEEE Trans Nucl Sci , vol.NS-29 , pp. 539-543
    • Eriksson, L.1    Bohm, C.2    Kesselberg, M.3
  • 5
    • 84939045331 scopus 로고
    • A multicrystal twodimensional BGO detector system for positron emission tomography
    • Casey ME, Nutt R. A multicrystal twodimensional BGO detector system for positron emission tomography. IEEE Trans Nucl Sci 1986: NS-33; 460-463.
    • (1986) IEEE Trans Nucl Sci , vol.NS-33 , pp. 460-463
    • Casey, M.E.1    Nutt, R.2
  • 6
    • 0024612104 scopus 로고
    • Three-dimensional reconstruction of PET data from a multi-ring camera
    • Townsend DW, Spinks TJ, Jones T, et al. Three-dimensional reconstruction of PET data from a multi-ring camera. IEEE Trans Nucl Sci 1989: NS-36; 1056-1065.
    • (1989) IEEE Trans Nucl Sci , vol.NS-36 , pp. 1056-1065
    • Townsend, D.W.1    Spinks, T.J.2    Jones, T.3
  • 7
    • 0025780950 scopus 로고
    • 3D PET using a conventional multislice tomograph without septa
    • Cherry SR, Dahlbom M, Hoffman EJ. 3D PET using a conventional multislice tomograph without septa. J Comput Assist Tomogr 1991: 15; 655-668.
    • (1991) J Comput Assist Tomogr , vol.15 , pp. 655-668
    • Cherry, S.R.1    Dahlbom, M.2    Hoffman, E.J.3
  • 8
    • 0028068644 scopus 로고
    • Performance characteristics of a whole-body PET scanner
    • DeGrado TR, Turkington TG, Williams JJ, et al. Performance characteristics of a whole-body PET scanner. J Nucl Med 1994: 35; 1398-1406.
    • (1994) J Nucl Med , vol.35 , pp. 1398-1406
    • Degrado, T.R.1    Turkington, T.G.2    Williams, J.J.3
  • 9
    • 0028006399 scopus 로고
    • The ECAT EXACT HR: Performance of a new high resolution positron scanner
    • Wienhard K, Dahlbom M, Eriksson L, et al. The ECAT EXACT HR: Performance of a new high resolution positron scanner. J Comput Assist Tomogr 1994: 18; 110-118.
    • (1994) J Comput Assist Tomogr , vol.18 , pp. 110-118
    • Wienhard, K.1    Dahlbom, M.2    Eriksson, L.3
  • 10
    • 0025335462 scopus 로고
    • Continuous-slice PENN-PET: A positron tomograph with volume imaging capability
    • Karp JS, Muehllehner G, Mankoff DA, et al. Continuous-slice PENN-PET: A positron tomograph with volume imaging capability. J Nucl Med 1990: 31; 617-627.
    • (1990) J Nucl Med , vol.31 , pp. 617-627
    • Karp, J.S.1    Muehllehner, G.2    Mankoff, D.A.3
  • 11
    • 0026802021 scopus 로고
    • Performance evaluation of the positron scanner ECAT EXACT
    • Wienhard K, Eriksson L, Grootoonk S, et al. Performance evaluation of the positron scanner ECAT EXACT. J Comput Assist Tomogr 1992: 16; 804-813.
    • (1992) J Comput Assist Tomogr , vol.16 , pp. 804-813
    • Wienhard, K.1    Eriksson, L.2    Grootoonk, S.3
  • 12
    • 0025335461 scopus 로고
    • Design and performance of Posicam 6.5 BGO positron camera
    • Mullani NA, Gould KL, Hartz RK, et al: Design and performance of Posicam 6.5 BGO positron camera. J Nucl Med 1990: 31; 610-616.
    • (1990) J Nucl Med , vol.31 , pp. 610-616
    • Mullani, N.A.1    Gould, K.L.2    Hartz, R.K.3
  • 13
    • 0026384823 scopus 로고
    • Physical characteristics of the ECAT 953B/31: A new high resolution brain positron tomograph
    • Mazoyer B, Trebossen R, Deutch R, et al. Physical characteristics of the ECAT 953B/31: a new high resolution brain positron tomograph. IEEE Trans Med Imag 1991: MT-10; 499-504.
    • (1991) IEEE Trans Med Imag , vol.MT-10 , pp. 499-504
    • Mazoyer, B.1    Trebossen, R.2    Deutch, R.3
  • 14
    • 0025414253 scopus 로고
    • PET scanner sensitivity: Relating count rates to image signal-to-noise ratio using noise equivalent counts
    • Strother SC, Casey ME, Hoffman EJ. PET scanner sensitivity: relating count rates to image signal-to-noise ratio using noise equivalent counts. IEEE Trans Nucl Sci 1990: 37; 783-788.
    • (1990) IEEE Trans Nucl Sci , vol.37 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.