메뉴 건너뛰기




Volumn 2, Issue 1, 1998, Pages 5-10

Evidence-based surgery: a brief report on the development of a cemented custom hip-replacement stem

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0013042972     PISSN: 13613111     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1361-3111(98)80004-6     Document Type: Article
Times cited : (3)

References (23)
  • 3
    • 0027579798 scopus 로고
    • Effects of hip centre location on the moment generating capacity of the muscles
    • Delp S.L., and Maloney W. Effects of hip centre location on the moment generating capacity of the muscles. Journal of Biomechanics 26 4/5 (1993) 485-499
    • (1993) Journal of Biomechanics , vol.26 , Issue.4-5 , pp. 485-499
    • Delp, S.L.1    Maloney, W.2
  • 7
    • 0027489640 scopus 로고
    • Mechanical failure in total hip replacement
    • Huiskes R. Mechanical failure in total hip replacement. Current Orthopaedics 7 (1993) 239-247
    • (1993) Current Orthopaedics , vol.7 , pp. 239-247
    • Huiskes, R.1
  • 8
    • 77949564321 scopus 로고
    • The effect of acetabular and feoral component placement on final hip geometry using the Belfast Custom Hip Replacement
    • Puerto Rico
    • James P.J., O'Brien S., Galway C., Engela D.W., and Beverland D.E. The effect of acetabular and feoral component placement on final hip geometry using the Belfast Custom Hip Replacement. 8th ISTA Conference. Puerto Rico (1995)
    • (1995) 8th ISTA Conference
    • James, P.J.1    O'Brien, S.2    Galway, C.3    Engela, D.W.4    Beverland, D.E.5
  • 11
    • 0026495786 scopus 로고
    • Factors influencing survivorship of the femoral component after primary low-friction hip arthroplasty
    • Kobayashi S., and Terayama K. Factors influencing survivorship of the femoral component after primary low-friction hip arthroplasty. Journal of Arthroplasty 7 (1992) 327-388
    • (1992) Journal of Arthroplasty , vol.7 , pp. 327-388
    • Kobayashi, S.1    Terayama, K.2
  • 13
    • 84993007347 scopus 로고
    • Improved stem fixation using intramedullary bone block technique: a prospective review of results in young patients
    • Manning M.P., Siney P.D., and Wroblewski M. Improved stem fixation using intramedullary bone block technique: a prospective review of results in young patients. Journal of Bone and Joint Surgery 76B (1994)
    • (1994) Journal of Bone and Joint Surgery , vol.76 B
    • Manning, M.P.1    Siney, P.D.2    Wroblewski, M.3
  • 14
    • 0024778662 scopus 로고
    • Strain gauge and photoelastic evaluation of the load transfer in the pelvis in total hip replacement: the effect of the position of the axis of rotation
    • H
    • Miles A.W., and McNamee P.B. Strain gauge and photoelastic evaluation of the load transfer in the pelvis in total hip replacement: the effect of the position of the axis of rotation. Proc ImechE 203 (1989) 103-107 H
    • (1989) Proc ImechE , vol.203 , pp. 103-107
    • Miles, A.W.1    McNamee, P.B.2
  • 15
    • 0025161599 scopus 로고
    • The effect of improved cementing techniques on component loosening in total hip replacement
    • Mulroy R.D., and Harris W.H. The effect of improved cementing techniques on component loosening in total hip replacement. JBJS 72B (1990) 757-760
    • (1990) JBJS , vol.72 B , pp. 757-760
    • Mulroy, R.D.1    Harris, W.H.2
  • 18
    • 0342871549 scopus 로고
    • The optimum cement mantle for total hip replacement: theory and practice: extended longevity in modern cemented arthroplasties
    • AAOS, Washington
    • Noble P.C., Tullos H.S., and Landon G.C. The optimum cement mantle for total hip replacement: theory and practice: extended longevity in modern cemented arthroplasties. Instructional course notes (No. 307) (1992), AAOS, Washington 145-150
    • (1992) Instructional course notes (No. 307) , pp. 145-150
    • Noble, P.C.1    Tullos, H.S.2    Landon, G.C.3
  • 20
    • 77949629309 scopus 로고
    • The manufacture and evaluation of custom acetabular components for total hip replacement
    • Faculty of Engineering. Queens University Belfast
    • Revie I.C. The manufacture and evaluation of custom acetabular components for total hip replacement. PhD Thesis (1995) Faculty of Engineering. Queens University Belfast
    • (1995) PhD Thesis
    • Revie, I.C.1
  • 22
    • 0023924033 scopus 로고
    • Socket design and cement pressurisation in the Charnley low-friction arthroplasty
    • Shelley P., and Wroblewski B.M. Socket design and cement pressurisation in the Charnley low-friction arthroplasty. Journal of Bone and Joint Surgery 70B (1988) 358-363
    • (1988) Journal of Bone and Joint Surgery , vol.70 B , pp. 358-363
    • Shelley, P.1    Wroblewski, B.M.2
  • 23
    • 0023929635 scopus 로고
    • Total hip acetabular component position affects component loosening rates
    • Yoder S.A., Brand R., Pedersen D., and O'Gorman T. Total hip acetabular component position affects component loosening rates. Clinical Orthopaedics 228 (1988) 79-87
    • (1988) Clinical Orthopaedics , vol.228 , pp. 79-87
    • Yoder, S.A.1    Brand, R.2    Pedersen, D.3    O'Gorman, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.